Single-stage buck–boost inverter with feedforward control
The off-grid inverter with the inverter side voltage as the feedback parameter has the advantages of a single voltage loop, simple control parameter design, and low cost. But the output voltage accuracy is not enough. A single-stage off-grid inverter with feedforward control is recommended to improv...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2023-10-01
|
Series: | Energy Reports |
Subjects: | |
Online Access: | http://www.sciencedirect.com/science/article/pii/S235248472300896X |
_version_ | 1797388822479110144 |
---|---|
author | Liang Cai Zhilei Yao |
author_facet | Liang Cai Zhilei Yao |
author_sort | Liang Cai |
collection | DOAJ |
description | The off-grid inverter with the inverter side voltage as the feedback parameter has the advantages of a single voltage loop, simple control parameter design, and low cost. But the output voltage accuracy is not enough. A single-stage off-grid inverter with feedforward control is recommended to improve the output voltage accuracy. It has a higher voltage regulation rate compared to the proportional–integral (PI) control and it can track a given AC signal at any frequency compared to the proportional-resonant (PR) control. Bus capacitors can employ thin-film capacitors for improved reliability and higher power density and the voltage stress on power devices can be decreased by controlling the intermediate bus voltage to a non-constant value. The working principle is explained. The design principles of the parameters are provided and the external characteristics and stability of the system are analyzed. A simulation model was built to verify the control strategy for improving voltage accuracy and decreasing voltage stress. |
first_indexed | 2024-03-08T22:46:24Z |
format | Article |
id | doaj.art-8931d3d3b84c4ec3b665160ee66ceb9e |
institution | Directory Open Access Journal |
issn | 2352-4847 |
language | English |
last_indexed | 2024-03-08T22:46:24Z |
publishDate | 2023-10-01 |
publisher | Elsevier |
record_format | Article |
series | Energy Reports |
spelling | doaj.art-8931d3d3b84c4ec3b665160ee66ceb9e2023-12-17T06:39:05ZengElsevierEnergy Reports2352-48472023-10-019204209Single-stage buck–boost inverter with feedforward controlLiang Cai0Zhilei Yao1Department of Electrical Engineering, Shanghai Maritime University, Shanghai 201306, ChinaCorresponding author.; Department of Electrical Engineering, Shanghai Maritime University, Shanghai 201306, ChinaThe off-grid inverter with the inverter side voltage as the feedback parameter has the advantages of a single voltage loop, simple control parameter design, and low cost. But the output voltage accuracy is not enough. A single-stage off-grid inverter with feedforward control is recommended to improve the output voltage accuracy. It has a higher voltage regulation rate compared to the proportional–integral (PI) control and it can track a given AC signal at any frequency compared to the proportional-resonant (PR) control. Bus capacitors can employ thin-film capacitors for improved reliability and higher power density and the voltage stress on power devices can be decreased by controlling the intermediate bus voltage to a non-constant value. The working principle is explained. The design principles of the parameters are provided and the external characteristics and stability of the system are analyzed. A simulation model was built to verify the control strategy for improving voltage accuracy and decreasing voltage stress.http://www.sciencedirect.com/science/article/pii/S235248472300896XVoltage accuracyOff-gridFeedforward controlSingle-stage |
spellingShingle | Liang Cai Zhilei Yao Single-stage buck–boost inverter with feedforward control Energy Reports Voltage accuracy Off-grid Feedforward control Single-stage |
title | Single-stage buck–boost inverter with feedforward control |
title_full | Single-stage buck–boost inverter with feedforward control |
title_fullStr | Single-stage buck–boost inverter with feedforward control |
title_full_unstemmed | Single-stage buck–boost inverter with feedforward control |
title_short | Single-stage buck–boost inverter with feedforward control |
title_sort | single stage buck boost inverter with feedforward control |
topic | Voltage accuracy Off-grid Feedforward control Single-stage |
url | http://www.sciencedirect.com/science/article/pii/S235248472300896X |
work_keys_str_mv | AT liangcai singlestagebuckboostinverterwithfeedforwardcontrol AT zhileiyao singlestagebuckboostinverterwithfeedforwardcontrol |