SYMMETRICAL CURRENT SOURCE FOR BIOIMPEDANCE MEASUREMENTS

Background. The object of the study is a symmetrical current source for bioimpedance measurements. The subject of the study is to determine the ways of occurrence of errors in the measurement of bioimpedance. The aim is to develop a method for reducing parasitic leakage of high-frequency current in...

Full description

Bibliographic Details
Main Authors: Vladimir V. Antipenko, Ekaterina A. Pecherskaya, Dmitriy V. Yakushov, Oleg V. Karpanin
Format: Article
Language:English
Published: Penza State University Publishing House 2023-10-01
Series:Измерение, мониторинг, управление, контроль
Subjects:
_version_ 1827789576682340352
author Vladimir V. Antipenko
Ekaterina A. Pecherskaya
Dmitriy V. Yakushov
Oleg V. Karpanin
author_facet Vladimir V. Antipenko
Ekaterina A. Pecherskaya
Dmitriy V. Yakushov
Oleg V. Karpanin
author_sort Vladimir V. Antipenko
collection DOAJ
description Background. The object of the study is a symmetrical current source for bioimpedance measurements. The subject of the study is to determine the ways of occurrence of errors in the measurement of bioimpedance. The aim is to develop a method for reducing parasitic leakage of high-frequency current in the process of bioimpedance measurement. Materials and methods. To determine the sources of measurement error, the idea of the paths of parasitic leakage currents into the ground is used. Results. A method is proposed to eliminate the parasitic effect of leakage current from the measuring object into the ground. As a result, the bioimpedance measurement circuit is insensitive to any types of leakage currents from the measuring object into the ground. Conclusions. The proposed symmetrical current source for bioimpedance measurements makes it possible to completely eliminate the influence of parasitic leakage current from the measuring object into the ground, which positively affects the accuracy and reliability of determining the parameters of the human body.
first_indexed 2024-03-11T17:22:44Z
format Article
id doaj.art-89de27e1bb1b4153bde656aebf207c08
institution Directory Open Access Journal
issn 2307-5538
language English
last_indexed 2024-03-11T17:22:44Z
publishDate 2023-10-01
publisher Penza State University Publishing House
record_format Article
series Измерение, мониторинг, управление, контроль
spelling doaj.art-89de27e1bb1b4153bde656aebf207c082023-10-19T09:53:30ZengPenza State University Publishing HouseИзмерение, мониторинг, управление, контроль2307-55382023-10-013doi:10.21685/2307-5538-2023-3-4SYMMETRICAL CURRENT SOURCE FOR BIOIMPEDANCE MEASUREMENTS Vladimir V. Antipenko0Ekaterina A. Pecherskaya1Dmitriy V. Yakushov2Oleg V. Karpanin3Penza State UniversityPenza State UniversityPenza State UniversityPenza State UniversityBackground. The object of the study is a symmetrical current source for bioimpedance measurements. The subject of the study is to determine the ways of occurrence of errors in the measurement of bioimpedance. The aim is to develop a method for reducing parasitic leakage of high-frequency current in the process of bioimpedance measurement. Materials and methods. To determine the sources of measurement error, the idea of the paths of parasitic leakage currents into the ground is used. Results. A method is proposed to eliminate the parasitic effect of leakage current from the measuring object into the ground. As a result, the bioimpedance measurement circuit is insensitive to any types of leakage currents from the measuring object into the ground. Conclusions. The proposed symmetrical current source for bioimpedance measurements makes it possible to completely eliminate the influence of parasitic leakage current from the measuring object into the ground, which positively affects the accuracy and reliability of determining the parameters of the human body. bioimpedancecurrentleakagepersonmeasurementerrorelectrodes
spellingShingle Vladimir V. Antipenko
Ekaterina A. Pecherskaya
Dmitriy V. Yakushov
Oleg V. Karpanin
SYMMETRICAL CURRENT SOURCE FOR BIOIMPEDANCE MEASUREMENTS
Измерение, мониторинг, управление, контроль
bioimpedance
current
leakage
person
measurement
error
electrodes
title SYMMETRICAL CURRENT SOURCE FOR BIOIMPEDANCE MEASUREMENTS
title_full SYMMETRICAL CURRENT SOURCE FOR BIOIMPEDANCE MEASUREMENTS
title_fullStr SYMMETRICAL CURRENT SOURCE FOR BIOIMPEDANCE MEASUREMENTS
title_full_unstemmed SYMMETRICAL CURRENT SOURCE FOR BIOIMPEDANCE MEASUREMENTS
title_short SYMMETRICAL CURRENT SOURCE FOR BIOIMPEDANCE MEASUREMENTS
title_sort symmetrical current source for bioimpedance measurements
topic bioimpedance
current
leakage
person
measurement
error
electrodes
work_keys_str_mv AT vladimirvantipenko symmetricalcurrentsourceforbioimpedancemeasurements
AT ekaterinaapecherskaya symmetricalcurrentsourceforbioimpedancemeasurements
AT dmitriyvyakushov symmetricalcurrentsourceforbioimpedancemeasurements
AT olegvkarpanin symmetricalcurrentsourceforbioimpedancemeasurements