Comparative characteristics of different methods of radiofrequency catheter ablation in atrial flutter

Catheter ablation occupies the first place in the treatment of atrial macro reentry arrhythmias. The main controllable parameters in ablations are energy, duration of exposure and use of catheter tip cooling. With traditional ablation techniques, there is a high risk of insufficient tissue damage du...

Full description

Bibliographic Details
Main Authors: A. V. Yakushev, O. Z. Paratsii
Format: Article
Language:English
Published: Zaporozhye State Medical University 2022-11-01
Series:Zaporožskij Medicinskij Žurnal
Subjects:
Online Access:http://zmj.zsmu.edu.ua/article/view/259489/262726
_version_ 1798015452134244352
author A. V. Yakushev
O. Z. Paratsii
author_facet A. V. Yakushev
O. Z. Paratsii
author_sort A. V. Yakushev
collection DOAJ
description Catheter ablation occupies the first place in the treatment of atrial macro reentry arrhythmias. The main controllable parameters in ablations are energy, duration of exposure and use of catheter tip cooling. With traditional ablation techniques, there is a high risk of insufficient tissue damage due to electrode instability. Regarding the issue of stability, a new technique was proposed – reducing the application time with increasing the energy. The aim of this work was to compare the results of radiofrequency catheter ablation (RFA) using an 8 mm uncooled electrode to a 4 mm cooled electrode and a 4 mm cooled electrode with increased energy. Materials and methods. The work is based on a retrospective analysis of the results of catheter ablations in patients with atrial flutter. Patients were divided into 3 groups depending on the parameters of the used radio frequency energy and the type of ablation electrode. Results. It was found that in the group with increased energy, there were the shortest time from the start of RFA to the achievement of success criteria and the lowest radiation exposure. The obtained differences were statistically significant in comparison with two groups of patients who underwent traditional methods. Such differences were associated both with a reduction in the time of the application itself due to the use of high energy as well as the need to apply a smaller number of applications owing to a lower probability of the electrode displacement from the target area. Conclusions. The use of a high-energy protocol allows to success criteria for cavo-tricuspid isthmus ablation more quickly compared to traditional techniques (by 30 % and 22 %, respectively) with less radiation exposure (by 27 % and 24 %, respectively). The use of the high-energy protocol does not lead to an increase in the frequency of complications and can be considered safe for clinical use.
first_indexed 2024-04-11T15:34:47Z
format Article
id doaj.art-8a0853115d5e43f2af7f02c01272f0bb
institution Directory Open Access Journal
issn 2306-4145
2310-1210
language English
last_indexed 2024-04-11T15:34:47Z
publishDate 2022-11-01
publisher Zaporozhye State Medical University
record_format Article
series Zaporožskij Medicinskij Žurnal
spelling doaj.art-8a0853115d5e43f2af7f02c01272f0bb2022-12-22T04:16:03ZengZaporozhye State Medical UniversityZaporožskij Medicinskij Žurnal2306-41452310-12102022-11-0124551652010.14739/2310-1210.2022.5.259489Comparative characteristics of different methods of radiofrequency catheter ablation in atrial flutterA. V. Yakushev0https://orcid.org/0000-0001-7888-1838O. Z. Paratsii1https://orcid.org/0000-0003-2455-7244SI “Amosov National Institute of Cardiovascular Surgery affiliated to National Academy of Medical Sciences of Ukraine”, KyivSI “Amosov National Institute of Cardiovascular Surgery affiliated to National Academy of Medical Sciences of Ukraine”, KyivCatheter ablation occupies the first place in the treatment of atrial macro reentry arrhythmias. The main controllable parameters in ablations are energy, duration of exposure and use of catheter tip cooling. With traditional ablation techniques, there is a high risk of insufficient tissue damage due to electrode instability. Regarding the issue of stability, a new technique was proposed – reducing the application time with increasing the energy. The aim of this work was to compare the results of radiofrequency catheter ablation (RFA) using an 8 mm uncooled electrode to a 4 mm cooled electrode and a 4 mm cooled electrode with increased energy. Materials and methods. The work is based on a retrospective analysis of the results of catheter ablations in patients with atrial flutter. Patients were divided into 3 groups depending on the parameters of the used radio frequency energy and the type of ablation electrode. Results. It was found that in the group with increased energy, there were the shortest time from the start of RFA to the achievement of success criteria and the lowest radiation exposure. The obtained differences were statistically significant in comparison with two groups of patients who underwent traditional methods. Such differences were associated both with a reduction in the time of the application itself due to the use of high energy as well as the need to apply a smaller number of applications owing to a lower probability of the electrode displacement from the target area. Conclusions. The use of a high-energy protocol allows to success criteria for cavo-tricuspid isthmus ablation more quickly compared to traditional techniques (by 30 % and 22 %, respectively) with less radiation exposure (by 27 % and 24 %, respectively). The use of the high-energy protocol does not lead to an increase in the frequency of complications and can be considered safe for clinical use.http://zmj.zsmu.edu.ua/article/view/259489/262726atrial flutteratrial fibrillationparoxysmal tachycardiareciprocating tachycardias
spellingShingle A. V. Yakushev
O. Z. Paratsii
Comparative characteristics of different methods of radiofrequency catheter ablation in atrial flutter
Zaporožskij Medicinskij Žurnal
atrial flutter
atrial fibrillation
paroxysmal tachycardia
reciprocating tachycardias
title Comparative characteristics of different methods of radiofrequency catheter ablation in atrial flutter
title_full Comparative characteristics of different methods of radiofrequency catheter ablation in atrial flutter
title_fullStr Comparative characteristics of different methods of radiofrequency catheter ablation in atrial flutter
title_full_unstemmed Comparative characteristics of different methods of radiofrequency catheter ablation in atrial flutter
title_short Comparative characteristics of different methods of radiofrequency catheter ablation in atrial flutter
title_sort comparative characteristics of different methods of radiofrequency catheter ablation in atrial flutter
topic atrial flutter
atrial fibrillation
paroxysmal tachycardia
reciprocating tachycardias
url http://zmj.zsmu.edu.ua/article/view/259489/262726
work_keys_str_mv AT avyakushev comparativecharacteristicsofdifferentmethodsofradiofrequencycatheterablationinatrialflutter
AT ozparatsii comparativecharacteristicsofdifferentmethodsofradiofrequencycatheterablationinatrialflutter