Evaluation of the adsorption capacity of nano-graphene and nano-graphene oxide for xylene removal from air and their comparison with the standard adsorbent of activated carbon to introduce the optimized one

Introduction: Volatile organic compounds from industrial activities are one of the most important pollutants released into the air and have adverse effects on human and environment. Therefore, they should be removed before releasing into atmosphere. The aim of the study was to evaluate xylene remova...

Full description

Bibliographic Details
Main Authors: Akram Tabrizi, Farideh Golbabaei, Hamid Shirkhanloo, Mostafa Jafarizaveh, Kamal azam, Rasoul Yarahmadi
Format: Article
Language:fas
Published: Tehran University of Medical Sciences 2016-06-01
Series:بهداشت و ایمنی کار
Subjects:
Online Access:http://jhsw.tums.ac.ir/browse.php?a_code=A-10-1-13&slc_lang=en&sid=1
_version_ 1818583473833639936
author Akram Tabrizi
Farideh Golbabaei
Hamid Shirkhanloo
Mostafa Jafarizaveh
Kamal azam
Rasoul Yarahmadi
author_facet Akram Tabrizi
Farideh Golbabaei
Hamid Shirkhanloo
Mostafa Jafarizaveh
Kamal azam
Rasoul Yarahmadi
author_sort Akram Tabrizi
collection DOAJ
description Introduction: Volatile organic compounds from industrial activities are one of the most important pollutants released into the air and have adverse effects on human and environment. Therefore, they should be removed before releasing into atmosphere. The aim of the study was to evaluate xylene removal from air by nano-grapheme and nano-graphene oxide in comparison with activated carbon adsorbent. Material and Method:  After preparing adsorbents of activated carbon, nano-graphene, and nano-graphene oxide, experiments adsorption capacity in static mode (Batch) were carried out in a glass vial. Some variables including contact time, the amount of adsorbent, the concentration of xylene, and the temperature were studied. Langmuir absorption isotherms were used in order to study the adsorption capacity of xylene on adsorbents. Moreover, sample analysis was done by gas chromatography with Flame Ionization Detector (GC-FID). Results: The adsorption capacities of activated carbon, nano-graphene oxide and nano-graphene for removal of xylene were obtained 349.8, 14.5, and 490 mg/g, respectively. The results of Scanning Electron Microscope (SEM) for nano-graphene and nano-graphene oxide showed particle size of less than 100 nm. While, the results of Transmission Electron Microscope (TEM) showed particle size of 45nm for nano-graphene and 65 nm for nano-graphene oxide. Also, X-Ray Diffraction (XRD) showed cube structure of nano-adsorbents. Conclusion: In constant humidity, increase in exposure time and temperature caused an increase in the adsorption capacity. The results revealed greater adsorption capacity of xylene removal for nano-graphene compared to the activated carbon, and nano-graphene oxide.
first_indexed 2024-12-16T08:05:51Z
format Article
id doaj.art-8a392992e0034f9cb383c81af422bf5a
institution Directory Open Access Journal
issn 2251-807X
2383-2088
language fas
last_indexed 2024-12-16T08:05:51Z
publishDate 2016-06-01
publisher Tehran University of Medical Sciences
record_format Article
series بهداشت و ایمنی کار
spelling doaj.art-8a392992e0034f9cb383c81af422bf5a2022-12-21T22:38:29ZfasTehran University of Medical Sciencesبهداشت و ایمنی کار2251-807X2383-20882016-06-01622534Evaluation of the adsorption capacity of nano-graphene and nano-graphene oxide for xylene removal from air and their comparison with the standard adsorbent of activated carbon to introduce the optimized oneAkram Tabrizi0Farideh Golbabaei1Hamid Shirkhanloo2Mostafa Jafarizaveh3Kamal azam4Rasoul Yarahmadi5 M.Sc. Student, Department of Occupational Health Engineering, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran Professor of Occupational Health Engineering, Department of Occupational Health, Faculty of Health, Tehran University of Medical Sciences, Tehran, Iran Assistant Professor, Iranian Petroleum Industry Health Research Institute (IPIHRI), Tehran, Iran M.Sc. Student, Department of Occupational Health Engineering, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran Assistant Professor of Biostatistics, Tehran University of Medical Sciences, Tehran, Iran Assistant Professor of Occupational Health Engineering, Department of Occupational Health, Faculty of Health, Iran University of Medical Sciences, Tehran, Iran Introduction: Volatile organic compounds from industrial activities are one of the most important pollutants released into the air and have adverse effects on human and environment. Therefore, they should be removed before releasing into atmosphere. The aim of the study was to evaluate xylene removal from air by nano-grapheme and nano-graphene oxide in comparison with activated carbon adsorbent. Material and Method:  After preparing adsorbents of activated carbon, nano-graphene, and nano-graphene oxide, experiments adsorption capacity in static mode (Batch) were carried out in a glass vial. Some variables including contact time, the amount of adsorbent, the concentration of xylene, and the temperature were studied. Langmuir absorption isotherms were used in order to study the adsorption capacity of xylene on adsorbents. Moreover, sample analysis was done by gas chromatography with Flame Ionization Detector (GC-FID). Results: The adsorption capacities of activated carbon, nano-graphene oxide and nano-graphene for removal of xylene were obtained 349.8, 14.5, and 490 mg/g, respectively. The results of Scanning Electron Microscope (SEM) for nano-graphene and nano-graphene oxide showed particle size of less than 100 nm. While, the results of Transmission Electron Microscope (TEM) showed particle size of 45nm for nano-graphene and 65 nm for nano-graphene oxide. Also, X-Ray Diffraction (XRD) showed cube structure of nano-adsorbents. Conclusion: In constant humidity, increase in exposure time and temperature caused an increase in the adsorption capacity. The results revealed greater adsorption capacity of xylene removal for nano-graphene compared to the activated carbon, and nano-graphene oxide.http://jhsw.tums.ac.ir/browse.php?a_code=A-10-1-13&slc_lang=en&sid=1Activated Carbon Adsorption Nano-Graphene Nano-Graphene Oxide Xylene
spellingShingle Akram Tabrizi
Farideh Golbabaei
Hamid Shirkhanloo
Mostafa Jafarizaveh
Kamal azam
Rasoul Yarahmadi
Evaluation of the adsorption capacity of nano-graphene and nano-graphene oxide for xylene removal from air and their comparison with the standard adsorbent of activated carbon to introduce the optimized one
بهداشت و ایمنی کار
Activated Carbon
Adsorption
Nano-Graphene
Nano-Graphene Oxide
Xylene
title Evaluation of the adsorption capacity of nano-graphene and nano-graphene oxide for xylene removal from air and their comparison with the standard adsorbent of activated carbon to introduce the optimized one
title_full Evaluation of the adsorption capacity of nano-graphene and nano-graphene oxide for xylene removal from air and their comparison with the standard adsorbent of activated carbon to introduce the optimized one
title_fullStr Evaluation of the adsorption capacity of nano-graphene and nano-graphene oxide for xylene removal from air and their comparison with the standard adsorbent of activated carbon to introduce the optimized one
title_full_unstemmed Evaluation of the adsorption capacity of nano-graphene and nano-graphene oxide for xylene removal from air and their comparison with the standard adsorbent of activated carbon to introduce the optimized one
title_short Evaluation of the adsorption capacity of nano-graphene and nano-graphene oxide for xylene removal from air and their comparison with the standard adsorbent of activated carbon to introduce the optimized one
title_sort evaluation of the adsorption capacity of nano graphene and nano graphene oxide for xylene removal from air and their comparison with the standard adsorbent of activated carbon to introduce the optimized one
topic Activated Carbon
Adsorption
Nano-Graphene
Nano-Graphene Oxide
Xylene
url http://jhsw.tums.ac.ir/browse.php?a_code=A-10-1-13&slc_lang=en&sid=1
work_keys_str_mv AT akramtabrizi evaluationoftheadsorptioncapacityofnanographeneandnanographeneoxideforxyleneremovalfromairandtheircomparisonwiththestandardadsorbentofactivatedcarbontointroducetheoptimizedone
AT faridehgolbabaei evaluationoftheadsorptioncapacityofnanographeneandnanographeneoxideforxyleneremovalfromairandtheircomparisonwiththestandardadsorbentofactivatedcarbontointroducetheoptimizedone
AT hamidshirkhanloo evaluationoftheadsorptioncapacityofnanographeneandnanographeneoxideforxyleneremovalfromairandtheircomparisonwiththestandardadsorbentofactivatedcarbontointroducetheoptimizedone
AT mostafajafarizaveh evaluationoftheadsorptioncapacityofnanographeneandnanographeneoxideforxyleneremovalfromairandtheircomparisonwiththestandardadsorbentofactivatedcarbontointroducetheoptimizedone
AT kamalazam evaluationoftheadsorptioncapacityofnanographeneandnanographeneoxideforxyleneremovalfromairandtheircomparisonwiththestandardadsorbentofactivatedcarbontointroducetheoptimizedone
AT rasoulyarahmadi evaluationoftheadsorptioncapacityofnanographeneandnanographeneoxideforxyleneremovalfromairandtheircomparisonwiththestandardadsorbentofactivatedcarbontointroducetheoptimizedone