Comparative Study of Dental Custom CAD-CAM Implant Abutments and Dental Implant Stock Abutments
The implementation of CAD-CAM systems in dentistry has significantly influenced the evolution of dental implantology and implant-supported prosthetics within the past three decades. Implant-supported prostheses are comfortable and aesthetic. The prosthetic abutment has also faced a rapid design evol...
Main Authors: | , , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2023-03-01
|
Series: | Journal of Clinical Medicine |
Subjects: | |
Online Access: | https://www.mdpi.com/2077-0383/12/6/2128 |
_version_ | 1797611025165451264 |
---|---|
author | Daniel Adrian Târtea Mihaela Ionescu Horia Octavian Manolea Veronica Mercuț Eugenia Obădan Marina Olimpia Amărăscu Petre Costin Mărășescu Luminița Dăguci Sanda Mihaela Popescu |
author_facet | Daniel Adrian Târtea Mihaela Ionescu Horia Octavian Manolea Veronica Mercuț Eugenia Obădan Marina Olimpia Amărăscu Petre Costin Mărășescu Luminița Dăguci Sanda Mihaela Popescu |
author_sort | Daniel Adrian Târtea |
collection | DOAJ |
description | The implementation of CAD-CAM systems in dentistry has significantly influenced the evolution of dental implantology and implant-supported prosthetics within the past three decades. Implant-supported prostheses are comfortable and aesthetic. The prosthetic abutment has also faced a rapid design evolution, from the individualization of standard stock abutments offered by various manufacturers to a modern customization process using CAD-CAM technology. This paper presents a comparative study between 20 dental custom CAD-CAM implant abutments and 20 dental implant stock abutments, based on a set of measurements performed on the digital casts obtained from 24 cases of prosthetic rehabilitation on implants. The statistical analysis (Mann–Whitney U test) revealed significant differences between these two types of abutments: the incisal margin line diameter dimensions for custom abutments were significantly improved compared to standard abutments at the cervical level (U = 343.00, z = 3.868, <i>p</i> < 0.0005) and the incisal/occlusal level (U = 352.00, z = 4.112, <i>p</i> < 0.0005), while the inclination angle of the custom abutments relative to the 0-axis was significantly smaller than that of standard abutments (U = 115.50, z = −2.286, <i>p</i> = 0.022). The use of custom abutments leads to an increase in the final size of the abutment, an improvement in the retention of the prosthetic work, and reduces the angulation of the abutment in relation to the implant axis, thus decreasing the risk of unscrewing or fracturing the dental screw. |
first_indexed | 2024-03-11T06:23:10Z |
format | Article |
id | doaj.art-8a3a5281cda4477cbcfca5ebcc9336d2 |
institution | Directory Open Access Journal |
issn | 2077-0383 |
language | English |
last_indexed | 2024-03-11T06:23:10Z |
publishDate | 2023-03-01 |
publisher | MDPI AG |
record_format | Article |
series | Journal of Clinical Medicine |
spelling | doaj.art-8a3a5281cda4477cbcfca5ebcc9336d22023-11-17T11:48:27ZengMDPI AGJournal of Clinical Medicine2077-03832023-03-01126212810.3390/jcm12062128Comparative Study of Dental Custom CAD-CAM Implant Abutments and Dental Implant Stock AbutmentsDaniel Adrian Târtea0Mihaela Ionescu1Horia Octavian Manolea2Veronica Mercuț3Eugenia Obădan4Marina Olimpia Amărăscu5Petre Costin Mărășescu6Luminița Dăguci7Sanda Mihaela Popescu8Department of Oral Rehabilitation, University of Medicine and Pharmacy of Craiova, 200349 Craiova, RomaniaDepartment of Medical Informatics and Biostatistics, University of Medicine and Pharmacy of Craiova, 200349 Craiova, RomaniaDepartment of Dental Materials, University of Medicine and Pharmacy of Craiova, 200349 Craiova, RomaniaDepartment of Dental Prosthetics, University of Medicine and Pharmacy of Craiova, 200349 Craiova, RomaniaDepartment of Dental Materials, University of Medicine and Pharmacy of Craiova, 200349 Craiova, RomaniaDepartment of Dental Morphology, University of Medicine and Pharmacy of Craiova, 200349 Craiova, RomaniaDepartment of Dental Technology, University of Medicine and Pharmacy of Craiova, 200349 Craiova, RomaniaDepartment of Dental Prosthetics, University of Medicine and Pharmacy of Craiova, 200349 Craiova, RomaniaDepartment of Oral Rehabilitation, University of Medicine and Pharmacy of Craiova, 200349 Craiova, RomaniaThe implementation of CAD-CAM systems in dentistry has significantly influenced the evolution of dental implantology and implant-supported prosthetics within the past three decades. Implant-supported prostheses are comfortable and aesthetic. The prosthetic abutment has also faced a rapid design evolution, from the individualization of standard stock abutments offered by various manufacturers to a modern customization process using CAD-CAM technology. This paper presents a comparative study between 20 dental custom CAD-CAM implant abutments and 20 dental implant stock abutments, based on a set of measurements performed on the digital casts obtained from 24 cases of prosthetic rehabilitation on implants. The statistical analysis (Mann–Whitney U test) revealed significant differences between these two types of abutments: the incisal margin line diameter dimensions for custom abutments were significantly improved compared to standard abutments at the cervical level (U = 343.00, z = 3.868, <i>p</i> < 0.0005) and the incisal/occlusal level (U = 352.00, z = 4.112, <i>p</i> < 0.0005), while the inclination angle of the custom abutments relative to the 0-axis was significantly smaller than that of standard abutments (U = 115.50, z = −2.286, <i>p</i> = 0.022). The use of custom abutments leads to an increase in the final size of the abutment, an improvement in the retention of the prosthetic work, and reduces the angulation of the abutment in relation to the implant axis, thus decreasing the risk of unscrewing or fracturing the dental screw.https://www.mdpi.com/2077-0383/12/6/2128dental prosthesesCAD/CAMdental technologyevaluation methods |
spellingShingle | Daniel Adrian Târtea Mihaela Ionescu Horia Octavian Manolea Veronica Mercuț Eugenia Obădan Marina Olimpia Amărăscu Petre Costin Mărășescu Luminița Dăguci Sanda Mihaela Popescu Comparative Study of Dental Custom CAD-CAM Implant Abutments and Dental Implant Stock Abutments Journal of Clinical Medicine dental prostheses CAD/CAM dental technology evaluation methods |
title | Comparative Study of Dental Custom CAD-CAM Implant Abutments and Dental Implant Stock Abutments |
title_full | Comparative Study of Dental Custom CAD-CAM Implant Abutments and Dental Implant Stock Abutments |
title_fullStr | Comparative Study of Dental Custom CAD-CAM Implant Abutments and Dental Implant Stock Abutments |
title_full_unstemmed | Comparative Study of Dental Custom CAD-CAM Implant Abutments and Dental Implant Stock Abutments |
title_short | Comparative Study of Dental Custom CAD-CAM Implant Abutments and Dental Implant Stock Abutments |
title_sort | comparative study of dental custom cad cam implant abutments and dental implant stock abutments |
topic | dental prostheses CAD/CAM dental technology evaluation methods |
url | https://www.mdpi.com/2077-0383/12/6/2128 |
work_keys_str_mv | AT danieladriantartea comparativestudyofdentalcustomcadcamimplantabutmentsanddentalimplantstockabutments AT mihaelaionescu comparativestudyofdentalcustomcadcamimplantabutmentsanddentalimplantstockabutments AT horiaoctavianmanolea comparativestudyofdentalcustomcadcamimplantabutmentsanddentalimplantstockabutments AT veronicamercut comparativestudyofdentalcustomcadcamimplantabutmentsanddentalimplantstockabutments AT eugeniaobadan comparativestudyofdentalcustomcadcamimplantabutmentsanddentalimplantstockabutments AT marinaolimpiaamarascu comparativestudyofdentalcustomcadcamimplantabutmentsanddentalimplantstockabutments AT petrecostinmarasescu comparativestudyofdentalcustomcadcamimplantabutmentsanddentalimplantstockabutments AT luminitadaguci comparativestudyofdentalcustomcadcamimplantabutmentsanddentalimplantstockabutments AT sandamihaelapopescu comparativestudyofdentalcustomcadcamimplantabutmentsanddentalimplantstockabutments |