Estimation Accuracy of the Electric Field in Cable Insulation Based on Space Charge Measurement

Space charge measurement accuracy is crucial when assessing the suitability of cables for high-voltage direct current (DC) systems. This study assembled state-of-the-art analysis technologies, including time-domain deconvolution, to mark electric field estimation accuracy, which the present techniqu...

Full description

Bibliographic Details
Main Authors: Norikazu Fuse, Shosuke Morita, Satoru Miyazaki, Toshihiro Takahashi, Naohiro Hozumi
Format: Article
Language:English
Published: MDPI AG 2022-07-01
Series:Energies
Subjects:
Online Access:https://www.mdpi.com/1996-1073/15/13/4920
Description
Summary:Space charge measurement accuracy is crucial when assessing the suitability of cables for high-voltage direct current (DC) systems. This study assembled state-of-the-art analysis technologies, including time-domain deconvolution, to mark electric field estimation accuracy, which the present techniques achieve. The pulse electroacoustic method was applied to a 66 kV-class extruded cable, and waveforms were obtained and analyzed to reproduce the electric field distribution. The DC voltage was set to be sufficiently low so that the analysis results can be compared with Laplace’s equation. The statistical analysis of 81 waveforms under a DC voltage of 30 kV showed that the estimation accuracy was −0.3% ± 19.9% with a 95.4% confidence interval, even with the deconvolution parameter optimized. The estimated accuracy using the “reference” waveform is applied to waveforms at higher voltages since similar estimation accuracies were confirmed for waveforms obtained under a DC voltage of 45 kV.
ISSN:1996-1073