Application of digital immediate implant restoration and angle screw channel abutment in the aesthetic area:case report and literature review

Objective To investigate the application of digital immediate implant and angle screw channel abutment in the aesthetic area and the related influencing factors by reviewing the data of one case of immediate implant repair of the upper anterior teeth and related literature. Methods One case of refra...

Full description

Bibliographic Details
Main Authors: WAN Haoyuan, DONG Tianzhen, DENG Manjing
Format: Article
Language:zho
Published: Editorial Department of Journal of Prevention and Treatment for Stomatological Diseases 2020-07-01
Series:口腔疾病防治
Subjects:
Online Access:http://www.kqjbfz.com/CN/10.12016/j.issn.2096-1456.2020.07.007
_version_ 1818578043902361600
author WAN Haoyuan
DONG Tianzhen
DENG Manjing
author_facet WAN Haoyuan
DONG Tianzhen
DENG Manjing
author_sort WAN Haoyuan
collection DOAJ
description Objective To investigate the application of digital immediate implant and angle screw channel abutment in the aesthetic area and the related influencing factors by reviewing the data of one case of immediate implant repair of the upper anterior teeth and related literature. Methods One case of refractory chronic apicitis of the upper anterior teeth involved immediate implantation after extraction. The digital information of the patient was obtained by CBCT and intraoral scanning. According to the information from the patients, a preoperative evaluation was performed; a treatment scheme was formulated; a minimally invasive extraction was performed; implants were placed under a digital guide plate; and temporary restoration was immediately performed. Six months after the operation, the patients underwent individualized mold removal, and angle screw channel fixation was completed. We observed the cosmetic effects and soft and hard tissue and gingival contour maintenance effects after restoration and reexamined the patients 6 months after restoration. In addition, the relevant literature was reviewed. Results The height of the gingival margin and gingival papilla and gingival contour of this patient were well maintained. The red and white aesthetic effect was good. There was no redness or swelling of the gingiva nor obvious changes in the soft and hard tissues around the implant 6 months after restoration, and the patient was satisfied. The results in the literature review show that a preoperative design based on CBCT and intraoral scanning data combined with digital software and a whole digital guide plate make the procedure more accurate and safer. These factors can not only avoid important anatomical structures and serious surgical complications but can also result in implantation in the best three-dimensional position. In addition, the application of digital impression technology and CAD/CAM increases the efficiency, speed, accuracy, simplicity, and comfort of oral impressions and the construction of temporary and final prostheses more precise and faster, greatly improving clinical efficiency. Conclusion Digital immediate implant and angle screw channel abutment is a good method to restore the aesthetics and function of missing teeth and to avoid the complications caused by adhesive residue.
first_indexed 2024-12-16T06:39:32Z
format Article
id doaj.art-8b5b10dbc5674f30bfa6e9ce082eccf0
institution Directory Open Access Journal
issn 2096-1456
2096-1456
language zho
last_indexed 2024-12-16T06:39:32Z
publishDate 2020-07-01
publisher Editorial Department of Journal of Prevention and Treatment for Stomatological Diseases
record_format Article
series 口腔疾病防治
spelling doaj.art-8b5b10dbc5674f30bfa6e9ce082eccf02022-12-21T22:40:43ZzhoEditorial Department of Journal of Prevention and Treatment for Stomatological Diseases口腔疾病防治2096-14562096-14562020-07-0128744344810.12016/j.issn.2096-1456.2020.07.007Application of digital immediate implant restoration and angle screw channel abutment in the aesthetic area:case report and literature reviewWAN Haoyuan0DONG Tianzhen1 DENG Manjing2Department of Stomatology, Da Ping Hospital, Amy Military Medical UniversityDepartment of Stomatology, Da Ping Hospital, Amy Military Medical UniversityDepartment of Stomatology, Da Ping Hospital, Amy Military Medical UniversityObjective To investigate the application of digital immediate implant and angle screw channel abutment in the aesthetic area and the related influencing factors by reviewing the data of one case of immediate implant repair of the upper anterior teeth and related literature. Methods One case of refractory chronic apicitis of the upper anterior teeth involved immediate implantation after extraction. The digital information of the patient was obtained by CBCT and intraoral scanning. According to the information from the patients, a preoperative evaluation was performed; a treatment scheme was formulated; a minimally invasive extraction was performed; implants were placed under a digital guide plate; and temporary restoration was immediately performed. Six months after the operation, the patients underwent individualized mold removal, and angle screw channel fixation was completed. We observed the cosmetic effects and soft and hard tissue and gingival contour maintenance effects after restoration and reexamined the patients 6 months after restoration. In addition, the relevant literature was reviewed. Results The height of the gingival margin and gingival papilla and gingival contour of this patient were well maintained. The red and white aesthetic effect was good. There was no redness or swelling of the gingiva nor obvious changes in the soft and hard tissues around the implant 6 months after restoration, and the patient was satisfied. The results in the literature review show that a preoperative design based on CBCT and intraoral scanning data combined with digital software and a whole digital guide plate make the procedure more accurate and safer. These factors can not only avoid important anatomical structures and serious surgical complications but can also result in implantation in the best three-dimensional position. In addition, the application of digital impression technology and CAD/CAM increases the efficiency, speed, accuracy, simplicity, and comfort of oral impressions and the construction of temporary and final prostheses more precise and faster, greatly improving clinical efficiency. Conclusion Digital immediate implant and angle screw channel abutment is a good method to restore the aesthetics and function of missing teeth and to avoid the complications caused by adhesive residue.http://www.kqjbfz.com/CN/10.12016/j.issn.2096-1456.2020.07.007digital immediate implantimplant repairangle screw channel abutmentpreoperative evaluationaesthetic areagingival contour dimensiongingival papillaaesthetic effectcement-retainedscrew-retained
spellingShingle WAN Haoyuan
DONG Tianzhen
DENG Manjing
Application of digital immediate implant restoration and angle screw channel abutment in the aesthetic area:case report and literature review
口腔疾病防治
digital immediate implant
implant repair
angle screw channel abutment
preoperative evaluation
aesthetic area
gingival contour dimension
gingival papilla
aesthetic effect
cement-retained
screw-retained
title Application of digital immediate implant restoration and angle screw channel abutment in the aesthetic area:case report and literature review
title_full Application of digital immediate implant restoration and angle screw channel abutment in the aesthetic area:case report and literature review
title_fullStr Application of digital immediate implant restoration and angle screw channel abutment in the aesthetic area:case report and literature review
title_full_unstemmed Application of digital immediate implant restoration and angle screw channel abutment in the aesthetic area:case report and literature review
title_short Application of digital immediate implant restoration and angle screw channel abutment in the aesthetic area:case report and literature review
title_sort application of digital immediate implant restoration and angle screw channel abutment in the aesthetic area case report and literature review
topic digital immediate implant
implant repair
angle screw channel abutment
preoperative evaluation
aesthetic area
gingival contour dimension
gingival papilla
aesthetic effect
cement-retained
screw-retained
url http://www.kqjbfz.com/CN/10.12016/j.issn.2096-1456.2020.07.007
work_keys_str_mv AT wanhaoyuan applicationofdigitalimmediateimplantrestorationandanglescrewchannelabutmentintheaestheticareacasereportandliteraturereview
AT dongtianzhen applicationofdigitalimmediateimplantrestorationandanglescrewchannelabutmentintheaestheticareacasereportandliteraturereview
AT dengmanjing applicationofdigitalimmediateimplantrestorationandanglescrewchannelabutmentintheaestheticareacasereportandliteraturereview