Intraoperative optical coherence tomography guided corneal sweeping for removal of remnant Interface fluid during ultra-thin Descemet stripping automated endothelial keratoplasty

Abstract Background Remnant interface fluid following Descemet stripping automated endothelial keratoplasty (DSAEK) is associated with postoperative detachments. The aim of this study was to assess outcomes of intraoperative optical coherence tomography (iOCT) guided meticulous peripheral corneal sw...

Full description

Bibliographic Details
Main Authors: Michael Mimouni, Martin Kronschläger, Manuel Ruiss, Oliver Findl
Format: Article
Language:English
Published: BMC 2021-04-01
Series:BMC Ophthalmology
Subjects:
Online Access:https://doi.org/10.1186/s12886-021-01934-2
_version_ 1818956027212595200
author Michael Mimouni
Martin Kronschläger
Manuel Ruiss
Oliver Findl
author_facet Michael Mimouni
Martin Kronschläger
Manuel Ruiss
Oliver Findl
author_sort Michael Mimouni
collection DOAJ
description Abstract Background Remnant interface fluid following Descemet stripping automated endothelial keratoplasty (DSAEK) is associated with postoperative detachments. The aim of this study was to assess outcomes of intraoperative optical coherence tomography (iOCT) guided meticulous peripheral corneal sweeping for removal of interface fluid during ultra-thin (UT) DSAEK. Methods This retrospective study included all eyes underwent iOCT guided UT-DSAEK from October 2016 to February 2018 at the Hanusch Hospital, Vienna, Austria. Peripheral meticulous corneal sweeping was performed to remove excess fluid. Central graft thickness (CGT) was measured prior to surgery, after graft bubbling and after corneal sweeping. Remnant interface fluid rates were compared between eyes that underwent rebubbling and those that did not. Results Overall, 28 eyes of 28 patients with a mean age of 73.9 ± 10.0 years were included. An iOCT guided meticulous peripheral sweeping was performed in 89.3% (n = 25) of the cases. Following 84% (n = 21) of the peripheral sweeping performed, remnant fluid was no longer identified. Following peripheral sweeping the interface fluid height was reduced from 17.31 ± 15.96 μm to 3.46 ± 9.52 μm (p < 0.001) and CGT was reduced by 7% (p < 0.001). Rebubbling was performed in 17.9% (n = 5) of the cases. The rebubbling group had a greater proportion of patients that had remnant fluid identified with iOCT at the end of surgery despite meticulous peripheral sweeping (60.0% versus 4.4%, p = 0.01). Conclusion The iOCT identified subclinical remnant fluid in nearly 90% of UT-DSAEK cases. An iOCT guided peripheral corneal sweeping led to resolution of interface fluid in a majority of cases. Eyes with persistent remnant fluid despite peripheral corneal sweeping are more likely to require subsequent rebubbling.
first_indexed 2024-12-20T10:47:25Z
format Article
id doaj.art-8b88adec169a40b5b0193c0c843dfb97
institution Directory Open Access Journal
issn 1471-2415
language English
last_indexed 2024-12-20T10:47:25Z
publishDate 2021-04-01
publisher BMC
record_format Article
series BMC Ophthalmology
spelling doaj.art-8b88adec169a40b5b0193c0c843dfb972022-12-21T19:43:21ZengBMCBMC Ophthalmology1471-24152021-04-012111710.1186/s12886-021-01934-2Intraoperative optical coherence tomography guided corneal sweeping for removal of remnant Interface fluid during ultra-thin Descemet stripping automated endothelial keratoplastyMichael Mimouni0Martin Kronschläger1Manuel Ruiss2Oliver Findl3Department of Ophthalmology, Rambam Health Care Campus, Haifa affiliated with the Bruce and Ruth Rappaport Faculty of Medicine, Technion-Israel Institute of TechnologyVienna Institute for Research in Ocular Surgery (VIROS), a Karl Landsteiner Institute, Hanusch HospitalVienna Institute for Research in Ocular Surgery (VIROS), a Karl Landsteiner Institute, Hanusch HospitalVienna Institute for Research in Ocular Surgery (VIROS), a Karl Landsteiner Institute, Hanusch HospitalAbstract Background Remnant interface fluid following Descemet stripping automated endothelial keratoplasty (DSAEK) is associated with postoperative detachments. The aim of this study was to assess outcomes of intraoperative optical coherence tomography (iOCT) guided meticulous peripheral corneal sweeping for removal of interface fluid during ultra-thin (UT) DSAEK. Methods This retrospective study included all eyes underwent iOCT guided UT-DSAEK from October 2016 to February 2018 at the Hanusch Hospital, Vienna, Austria. Peripheral meticulous corneal sweeping was performed to remove excess fluid. Central graft thickness (CGT) was measured prior to surgery, after graft bubbling and after corneal sweeping. Remnant interface fluid rates were compared between eyes that underwent rebubbling and those that did not. Results Overall, 28 eyes of 28 patients with a mean age of 73.9 ± 10.0 years were included. An iOCT guided meticulous peripheral sweeping was performed in 89.3% (n = 25) of the cases. Following 84% (n = 21) of the peripheral sweeping performed, remnant fluid was no longer identified. Following peripheral sweeping the interface fluid height was reduced from 17.31 ± 15.96 μm to 3.46 ± 9.52 μm (p < 0.001) and CGT was reduced by 7% (p < 0.001). Rebubbling was performed in 17.9% (n = 5) of the cases. The rebubbling group had a greater proportion of patients that had remnant fluid identified with iOCT at the end of surgery despite meticulous peripheral sweeping (60.0% versus 4.4%, p = 0.01). Conclusion The iOCT identified subclinical remnant fluid in nearly 90% of UT-DSAEK cases. An iOCT guided peripheral corneal sweeping led to resolution of interface fluid in a majority of cases. Eyes with persistent remnant fluid despite peripheral corneal sweeping are more likely to require subsequent rebubbling.https://doi.org/10.1186/s12886-021-01934-2Intraoperative optical coherence tomographyInterface fluidUT-DSAEKGraft thicknessSweeping
spellingShingle Michael Mimouni
Martin Kronschläger
Manuel Ruiss
Oliver Findl
Intraoperative optical coherence tomography guided corneal sweeping for removal of remnant Interface fluid during ultra-thin Descemet stripping automated endothelial keratoplasty
BMC Ophthalmology
Intraoperative optical coherence tomography
Interface fluid
UT-DSAEK
Graft thickness
Sweeping
title Intraoperative optical coherence tomography guided corneal sweeping for removal of remnant Interface fluid during ultra-thin Descemet stripping automated endothelial keratoplasty
title_full Intraoperative optical coherence tomography guided corneal sweeping for removal of remnant Interface fluid during ultra-thin Descemet stripping automated endothelial keratoplasty
title_fullStr Intraoperative optical coherence tomography guided corneal sweeping for removal of remnant Interface fluid during ultra-thin Descemet stripping automated endothelial keratoplasty
title_full_unstemmed Intraoperative optical coherence tomography guided corneal sweeping for removal of remnant Interface fluid during ultra-thin Descemet stripping automated endothelial keratoplasty
title_short Intraoperative optical coherence tomography guided corneal sweeping for removal of remnant Interface fluid during ultra-thin Descemet stripping automated endothelial keratoplasty
title_sort intraoperative optical coherence tomography guided corneal sweeping for removal of remnant interface fluid during ultra thin descemet stripping automated endothelial keratoplasty
topic Intraoperative optical coherence tomography
Interface fluid
UT-DSAEK
Graft thickness
Sweeping
url https://doi.org/10.1186/s12886-021-01934-2
work_keys_str_mv AT michaelmimouni intraoperativeopticalcoherencetomographyguidedcornealsweepingforremovalofremnantinterfacefluidduringultrathindescemetstrippingautomatedendothelialkeratoplasty
AT martinkronschlager intraoperativeopticalcoherencetomographyguidedcornealsweepingforremovalofremnantinterfacefluidduringultrathindescemetstrippingautomatedendothelialkeratoplasty
AT manuelruiss intraoperativeopticalcoherencetomographyguidedcornealsweepingforremovalofremnantinterfacefluidduringultrathindescemetstrippingautomatedendothelialkeratoplasty
AT oliverfindl intraoperativeopticalcoherencetomographyguidedcornealsweepingforremovalofremnantinterfacefluidduringultrathindescemetstrippingautomatedendothelialkeratoplasty