Textile electromyography electrodes reveal differences in lower limb muscle activation during loaded squats when comparing fixed and free barbell movement paths

IntroductionTraditional recordings of muscle activation often involve time-consuming application of surface electrodes affixed to the skin in laboratory environments. The development of textile electromyography (EMG) electrodes now allows fast and unobtrusive assessment of muscle activation in ecolo...

Full description

Bibliographic Details
Main Authors: Felicia Svensson, Ulrika Aasa, Andrew Strong
Format: Article
Language:English
Published: Frontiers Media S.A. 2022-11-01
Series:Frontiers in Sports and Active Living
Subjects:
Online Access:https://www.frontiersin.org/articles/10.3389/fspor.2022.1021323/full
_version_ 1797987064213405696
author Felicia Svensson
Ulrika Aasa
Andrew Strong
author_facet Felicia Svensson
Ulrika Aasa
Andrew Strong
author_sort Felicia Svensson
collection DOAJ
description IntroductionTraditional recordings of muscle activation often involve time-consuming application of surface electrodes affixed to the skin in laboratory environments. The development of textile electromyography (EMG) electrodes now allows fast and unobtrusive assessment of muscle activation in ecologically valid environments. In this study, textile EMG shorts were used to assess whether performing squats with the barbell resting freely on the shoulders or using a Smith machine for a fixed barbell movement path is preferable for maximizing lower limb muscle activation.MethodsSixteen athletes performed free and fixed barbell squats in a gym with external loads equivalent to their body mass. Quadriceps, hamstrings and gluteus maximus activation was measured bilaterally with textile EMG electrodes embedded in shorts.ResultsMean quadriceps activation was greater for the free compared with the fixed movement path for the right (mean difference [MD] 14μV, p = 0.04, ηp2 = 0.28) and left leg (MD 15μV, p = 0.01, ηp2 = 0.39) over the entire squat and specifically during the first half of the eccentric phase for the left leg (MD 7μV, p = 0.04, d = 0.56), second half of the eccentric phase for both legs (right leg MD 21μV, p = 0.05, d = 0.54; left leg MD 23μV, p = 0.04, d = 0.52) and the first half of the concentric phase for both legs (right leg MD 24μV, p = 0.04, d = 0.56; left leg MD 15μV, p = 0.01, d = 0.72). Greater hamstrings activation for the free path was seen for the second half of the eccentric phase (left leg MD 4μV, p = 0.03, d = 0.58) and first half of the concentric phase (right leg MD 5μV, p = 0.02, d = 0.72). No significant differences were found for gluteus maximus.DiscussionTextile EMG electrodes embedded in shorts revealed that to maximize thigh muscle activity during loaded squats, a free barbell movement path is preferable to a fixed barbell movement path.
first_indexed 2024-04-11T07:41:55Z
format Article
id doaj.art-8ba3adb4dcde42f9bfd60d9eee0307c3
institution Directory Open Access Journal
issn 2624-9367
language English
last_indexed 2024-04-11T07:41:55Z
publishDate 2022-11-01
publisher Frontiers Media S.A.
record_format Article
series Frontiers in Sports and Active Living
spelling doaj.art-8ba3adb4dcde42f9bfd60d9eee0307c32022-12-22T04:36:29ZengFrontiers Media S.A.Frontiers in Sports and Active Living2624-93672022-11-01410.3389/fspor.2022.10213231021323Textile electromyography electrodes reveal differences in lower limb muscle activation during loaded squats when comparing fixed and free barbell movement pathsFelicia SvenssonUlrika AasaAndrew StrongIntroductionTraditional recordings of muscle activation often involve time-consuming application of surface electrodes affixed to the skin in laboratory environments. The development of textile electromyography (EMG) electrodes now allows fast and unobtrusive assessment of muscle activation in ecologically valid environments. In this study, textile EMG shorts were used to assess whether performing squats with the barbell resting freely on the shoulders or using a Smith machine for a fixed barbell movement path is preferable for maximizing lower limb muscle activation.MethodsSixteen athletes performed free and fixed barbell squats in a gym with external loads equivalent to their body mass. Quadriceps, hamstrings and gluteus maximus activation was measured bilaterally with textile EMG electrodes embedded in shorts.ResultsMean quadriceps activation was greater for the free compared with the fixed movement path for the right (mean difference [MD] 14μV, p = 0.04, ηp2 = 0.28) and left leg (MD 15μV, p = 0.01, ηp2 = 0.39) over the entire squat and specifically during the first half of the eccentric phase for the left leg (MD 7μV, p = 0.04, d = 0.56), second half of the eccentric phase for both legs (right leg MD 21μV, p = 0.05, d = 0.54; left leg MD 23μV, p = 0.04, d = 0.52) and the first half of the concentric phase for both legs (right leg MD 24μV, p = 0.04, d = 0.56; left leg MD 15μV, p = 0.01, d = 0.72). Greater hamstrings activation for the free path was seen for the second half of the eccentric phase (left leg MD 4μV, p = 0.03, d = 0.58) and first half of the concentric phase (right leg MD 5μV, p = 0.02, d = 0.72). No significant differences were found for gluteus maximus.DiscussionTextile EMG electrodes embedded in shorts revealed that to maximize thigh muscle activity during loaded squats, a free barbell movement path is preferable to a fixed barbell movement path.https://www.frontiersin.org/articles/10.3389/fspor.2022.1021323/fullelectromyographyweightliftingresistance trainingmotor controlsquat
spellingShingle Felicia Svensson
Ulrika Aasa
Andrew Strong
Textile electromyography electrodes reveal differences in lower limb muscle activation during loaded squats when comparing fixed and free barbell movement paths
Frontiers in Sports and Active Living
electromyography
weightlifting
resistance training
motor control
squat
title Textile electromyography electrodes reveal differences in lower limb muscle activation during loaded squats when comparing fixed and free barbell movement paths
title_full Textile electromyography electrodes reveal differences in lower limb muscle activation during loaded squats when comparing fixed and free barbell movement paths
title_fullStr Textile electromyography electrodes reveal differences in lower limb muscle activation during loaded squats when comparing fixed and free barbell movement paths
title_full_unstemmed Textile electromyography electrodes reveal differences in lower limb muscle activation during loaded squats when comparing fixed and free barbell movement paths
title_short Textile electromyography electrodes reveal differences in lower limb muscle activation during loaded squats when comparing fixed and free barbell movement paths
title_sort textile electromyography electrodes reveal differences in lower limb muscle activation during loaded squats when comparing fixed and free barbell movement paths
topic electromyography
weightlifting
resistance training
motor control
squat
url https://www.frontiersin.org/articles/10.3389/fspor.2022.1021323/full
work_keys_str_mv AT feliciasvensson textileelectromyographyelectrodesrevealdifferencesinlowerlimbmuscleactivationduringloadedsquatswhencomparingfixedandfreebarbellmovementpaths
AT ulrikaaasa textileelectromyographyelectrodesrevealdifferencesinlowerlimbmuscleactivationduringloadedsquatswhencomparingfixedandfreebarbellmovementpaths
AT andrewstrong textileelectromyographyelectrodesrevealdifferencesinlowerlimbmuscleactivationduringloadedsquatswhencomparingfixedandfreebarbellmovementpaths