Studi Eksperimental Pengaruh Bilangan Reynolds pada Keefektifan dan Koefisien Tekanan Penukar Panas Berkas Pipa Eliptik Susunan Berseling

Experimental studies have been conducted on the elliptic tube bundle with a diameter equivalent to 0.75 inches and the aspect ratio (AR) = 2.Tube bundle arranged alternate with 4-3-4 configuration and pitch lateral (SL) = 1.5 X axis major axis. Meanwhile pitch transverse (ST) varied 1.5 and 2 X mino...

Full description

Bibliographic Details
Main Authors: Budi Utomo Kukuh Widodo, Samsul Kamal, Suhanan ., I Made Suardjaja
Format: Article
Language:English
Published: Universitas Udayana 2013-02-01
Series:Jurnal Energi Dan Manufaktur
Subjects:
Online Access:https://ojs.unud.ac.id/index.php/jem/article/view/4680
_version_ 1819123056513122304
author Budi Utomo Kukuh Widodo
Samsul Kamal
Suhanan .
I Made Suardjaja
author_facet Budi Utomo Kukuh Widodo
Samsul Kamal
Suhanan .
I Made Suardjaja
author_sort Budi Utomo Kukuh Widodo
collection DOAJ
description Experimental studies have been conducted on the elliptic tube bundle with a diameter equivalent to 0.75 inches and the aspect ratio (AR) = 2.Tube bundle arranged alternate with 4-3-4 configuration and pitch lateral (SL) = 1.5 X axis major axis. Meanwhile pitch transverse (ST) varied 1.5 and 2 X minor axis. The Testing was carried out in a subsonic wind tunnel with wind speeds of 1 m / s - 12.6 m / s resulting Reynolds number Reb = 346-6904 and operating temperature 49 oC, 59 oC and 69 oC. Seven tubes inserted an electric heater produces uniform heat flux 3718 W/m2 - 3751 W/m2. The results show that the effectiveness of the heat exchanger (Q / P) varied from 3799 to 15, decreases exponentially at low Reynolds number and tends to asymptotic at Reynolds number above 1000. Meanwhile, the value pressure coefficient (?p/0.5?V2) with value 3.4-10 decreased continuously at low Reynolds numbers and asymptotic at high Reynolds number. In general, a bundle with a smaller ST has greater effectiveness and the pressure coefficient ranges is wider. Changes in operating temperature conseqwenly no effect on the effectiveness and the pressure coefficient at high Reynolds number.
first_indexed 2024-12-22T07:02:17Z
format Article
id doaj.art-8bd0d6d39da842c6a16015a79fb86492
institution Directory Open Access Journal
issn 2302-5255
2541-5328
language English
last_indexed 2024-12-22T07:02:17Z
publishDate 2013-02-01
publisher Universitas Udayana
record_format Article
series Jurnal Energi Dan Manufaktur
spelling doaj.art-8bd0d6d39da842c6a16015a79fb864922022-12-21T18:34:46ZengUniversitas UdayanaJurnal Energi Dan Manufaktur2302-52552541-53282013-02-01514680Studi Eksperimental Pengaruh Bilangan Reynolds pada Keefektifan dan Koefisien Tekanan Penukar Panas Berkas Pipa Eliptik Susunan BerselingBudi Utomo Kukuh WidodoSamsul KamalSuhanan .I Made SuardjajaExperimental studies have been conducted on the elliptic tube bundle with a diameter equivalent to 0.75 inches and the aspect ratio (AR) = 2.Tube bundle arranged alternate with 4-3-4 configuration and pitch lateral (SL) = 1.5 X axis major axis. Meanwhile pitch transverse (ST) varied 1.5 and 2 X minor axis. The Testing was carried out in a subsonic wind tunnel with wind speeds of 1 m / s - 12.6 m / s resulting Reynolds number Reb = 346-6904 and operating temperature 49 oC, 59 oC and 69 oC. Seven tubes inserted an electric heater produces uniform heat flux 3718 W/m2 - 3751 W/m2. The results show that the effectiveness of the heat exchanger (Q / P) varied from 3799 to 15, decreases exponentially at low Reynolds number and tends to asymptotic at Reynolds number above 1000. Meanwhile, the value pressure coefficient (?p/0.5?V2) with value 3.4-10 decreased continuously at low Reynolds numbers and asymptotic at high Reynolds number. In general, a bundle with a smaller ST has greater effectiveness and the pressure coefficient ranges is wider. Changes in operating temperature conseqwenly no effect on the effectiveness and the pressure coefficient at high Reynolds number.https://ojs.unud.ac.id/index.php/jem/article/view/4680Section having an alternate elliptical tube, the effectiveness, pressure coefficient
spellingShingle Budi Utomo Kukuh Widodo
Samsul Kamal
Suhanan .
I Made Suardjaja
Studi Eksperimental Pengaruh Bilangan Reynolds pada Keefektifan dan Koefisien Tekanan Penukar Panas Berkas Pipa Eliptik Susunan Berseling
Jurnal Energi Dan Manufaktur
Section having an alternate elliptical tube, the effectiveness, pressure coefficient
title Studi Eksperimental Pengaruh Bilangan Reynolds pada Keefektifan dan Koefisien Tekanan Penukar Panas Berkas Pipa Eliptik Susunan Berseling
title_full Studi Eksperimental Pengaruh Bilangan Reynolds pada Keefektifan dan Koefisien Tekanan Penukar Panas Berkas Pipa Eliptik Susunan Berseling
title_fullStr Studi Eksperimental Pengaruh Bilangan Reynolds pada Keefektifan dan Koefisien Tekanan Penukar Panas Berkas Pipa Eliptik Susunan Berseling
title_full_unstemmed Studi Eksperimental Pengaruh Bilangan Reynolds pada Keefektifan dan Koefisien Tekanan Penukar Panas Berkas Pipa Eliptik Susunan Berseling
title_short Studi Eksperimental Pengaruh Bilangan Reynolds pada Keefektifan dan Koefisien Tekanan Penukar Panas Berkas Pipa Eliptik Susunan Berseling
title_sort studi eksperimental pengaruh bilangan reynolds pada keefektifan dan koefisien tekanan penukar panas berkas pipa eliptik susunan berseling
topic Section having an alternate elliptical tube, the effectiveness, pressure coefficient
url https://ojs.unud.ac.id/index.php/jem/article/view/4680
work_keys_str_mv AT budiutomokukuhwidodo studieksperimentalpengaruhbilanganreynoldspadakeefektifandankoefisientekananpenukarpanasberkaspipaeliptiksusunanberseling
AT samsulkamal studieksperimentalpengaruhbilanganreynoldspadakeefektifandankoefisientekananpenukarpanasberkaspipaeliptiksusunanberseling
AT suhanan studieksperimentalpengaruhbilanganreynoldspadakeefektifandankoefisientekananpenukarpanasberkaspipaeliptiksusunanberseling
AT imadesuardjaja studieksperimentalpengaruhbilanganreynoldspadakeefektifandankoefisientekananpenukarpanasberkaspipaeliptiksusunanberseling