Cutting a mediolateral episiotomy at the correct angle: evaluation of a new device, the Episcissors-60

RM Freeman,1,2 HJ Hollands,1 LF Barron,3 DS Kapoor41Directorate of Obstetrics and Gynaecology, Plymouth Hospitals NHS Trust, Derriford Hospital, 2Plymouth University Peninsula Schools of Medicine and Dentistry, 3Directorate of Healthcare Science and Technology at Plymouth Hospitals NHS Trust, Derrif...

Full description

Bibliographic Details
Main Authors: Freeman RM, Hollands HJ, Barron LF, Kapoor DS
Format: Article
Language:English
Published: Dove Medical Press 2014-02-01
Series:Medical Devices: Evidence and Research
Online Access:http://www.dovepress.com/cutting-a-mediolateral-episiotomy-at-the-correct-angle-evaluation-of-a-a15903
_version_ 1823966861119717376
author Freeman RM
Hollands HJ
Barron LF
Kapoor DS
author_facet Freeman RM
Hollands HJ
Barron LF
Kapoor DS
author_sort Freeman RM
collection DOAJ
description RM Freeman,1,2 HJ Hollands,1 LF Barron,3 DS Kapoor41Directorate of Obstetrics and Gynaecology, Plymouth Hospitals NHS Trust, Derriford Hospital, 2Plymouth University Peninsula Schools of Medicine and Dentistry, 3Directorate of Healthcare Science and Technology at Plymouth Hospitals NHS Trust, Derriford Hospital, Plymouth, 4Urogynaecology Unit, Royal Bournemouth Hospital, Bournemouth, UKBackground: Anal incontinence is nine times more prevalent in women than in men due to obstetric anal sphincter injury (OASI). OASI is linked to midline episiotomies and mediolateral episiotomies with post-delivery angles of <30 and >60 degrees. Studies show that doctors and midwives are unable to correctly "eyeball" the safe angle required due to perineal stretching by the fetal head at crowning. A new scissor instrument (Episcissors-60) was devised to allow cutting a mediolateral episiotomy at a fixed angle of 60 degrees from the perineal midline.Methods: Scissors with a marker guide limb pointing towards the anus were devised, ensuring an angle of 60 degrees between the scissor blades and the guide limb. This device was initially tested in models. Post-delivery angles were recorded on transparencies and analyzed by an author blinded to clinical details. Accoucheurs were asked to rate the ease of use on a 5-point scale.Results: Of the 17 women, 14 delivered with ventouse, two with forceps, and one with sequential ventouse–forceps. Indications for instrumental delivery were suboptimal cardiotocogram and/or prolonged second stage of labor. Mean birth weight was 3.41 (2.92–4.12) kg. A mean post-delivery angle of 42.4±7 (range 30–60, median 43) degrees (95% confidence interval 38.8–46) was achieved with the Episcissors-60 instrument. Eighty-eight percent of clinicians agreed or strongly agreed that the scissors were easy to use.Conclusion: The Episcissors-60 delivered a consistent post-delivery angle of 43 degrees. They could replace "eyeballing" when performing mediolateral episiotomies and form part of a preventative strategy to reduce OASI.Keywords: 60 degree episiotomy, anal incontinence, episiotomy scissors, mediolateral episiotomy, obstetric anal sphincter injury, OASI
first_indexed 2024-12-17T18:19:13Z
format Article
id doaj.art-8bf37d763e604d29af72317564bd9832
institution Directory Open Access Journal
issn 1179-1470
language English
last_indexed 2024-12-17T18:19:13Z
publishDate 2014-02-01
publisher Dove Medical Press
record_format Article
series Medical Devices: Evidence and Research
spelling doaj.art-8bf37d763e604d29af72317564bd98322022-12-21T21:37:36ZengDove Medical PressMedical Devices: Evidence and Research1179-14702014-02-012014default232815903Cutting a mediolateral episiotomy at the correct angle: evaluation of a new device, the Episcissors-60Freeman RMHollands HJBarron LFKapoor DSRM Freeman,1,2 HJ Hollands,1 LF Barron,3 DS Kapoor41Directorate of Obstetrics and Gynaecology, Plymouth Hospitals NHS Trust, Derriford Hospital, 2Plymouth University Peninsula Schools of Medicine and Dentistry, 3Directorate of Healthcare Science and Technology at Plymouth Hospitals NHS Trust, Derriford Hospital, Plymouth, 4Urogynaecology Unit, Royal Bournemouth Hospital, Bournemouth, UKBackground: Anal incontinence is nine times more prevalent in women than in men due to obstetric anal sphincter injury (OASI). OASI is linked to midline episiotomies and mediolateral episiotomies with post-delivery angles of <30 and >60 degrees. Studies show that doctors and midwives are unable to correctly "eyeball" the safe angle required due to perineal stretching by the fetal head at crowning. A new scissor instrument (Episcissors-60) was devised to allow cutting a mediolateral episiotomy at a fixed angle of 60 degrees from the perineal midline.Methods: Scissors with a marker guide limb pointing towards the anus were devised, ensuring an angle of 60 degrees between the scissor blades and the guide limb. This device was initially tested in models. Post-delivery angles were recorded on transparencies and analyzed by an author blinded to clinical details. Accoucheurs were asked to rate the ease of use on a 5-point scale.Results: Of the 17 women, 14 delivered with ventouse, two with forceps, and one with sequential ventouse–forceps. Indications for instrumental delivery were suboptimal cardiotocogram and/or prolonged second stage of labor. Mean birth weight was 3.41 (2.92–4.12) kg. A mean post-delivery angle of 42.4±7 (range 30–60, median 43) degrees (95% confidence interval 38.8–46) was achieved with the Episcissors-60 instrument. Eighty-eight percent of clinicians agreed or strongly agreed that the scissors were easy to use.Conclusion: The Episcissors-60 delivered a consistent post-delivery angle of 43 degrees. They could replace "eyeballing" when performing mediolateral episiotomies and form part of a preventative strategy to reduce OASI.Keywords: 60 degree episiotomy, anal incontinence, episiotomy scissors, mediolateral episiotomy, obstetric anal sphincter injury, OASIhttp://www.dovepress.com/cutting-a-mediolateral-episiotomy-at-the-correct-angle-evaluation-of-a-a15903
spellingShingle Freeman RM
Hollands HJ
Barron LF
Kapoor DS
Cutting a mediolateral episiotomy at the correct angle: evaluation of a new device, the Episcissors-60
Medical Devices: Evidence and Research
title Cutting a mediolateral episiotomy at the correct angle: evaluation of a new device, the Episcissors-60
title_full Cutting a mediolateral episiotomy at the correct angle: evaluation of a new device, the Episcissors-60
title_fullStr Cutting a mediolateral episiotomy at the correct angle: evaluation of a new device, the Episcissors-60
title_full_unstemmed Cutting a mediolateral episiotomy at the correct angle: evaluation of a new device, the Episcissors-60
title_short Cutting a mediolateral episiotomy at the correct angle: evaluation of a new device, the Episcissors-60
title_sort cutting a mediolateral episiotomy at the correct angle evaluation of a new device the episcissors 60
url http://www.dovepress.com/cutting-a-mediolateral-episiotomy-at-the-correct-angle-evaluation-of-a-a15903
work_keys_str_mv AT freemanrm cuttingamediolateralepisiotomyatthecorrectangleevaluationofanewdevicetheepiscissors60
AT hollandshj cuttingamediolateralepisiotomyatthecorrectangleevaluationofanewdevicetheepiscissors60
AT barronlf cuttingamediolateralepisiotomyatthecorrectangleevaluationofanewdevicetheepiscissors60
AT kapoords cuttingamediolateralepisiotomyatthecorrectangleevaluationofanewdevicetheepiscissors60