Hourglass-shaped grafts are superior to conventional grafts for restoring knee stability and graft force at knee flexion angle of 30° following anterior cruciate ligament reconstruction: A finite element analysis

Background: Anterior cruciate ligament reconstruction (ACLR) using a generally columnar graft is considered the gold standard for treating anterior cruciate ligament ruptures, but such grafts cannot replicate the geometry and mechanical properties of the native anterior cruciate ligament.Purpose: To...

Full description

Bibliographic Details
Main Authors: Huizhi Wang, Chaohua Fang, Mingzhu Tao, Qinyi Shi, Kaixin He, Cheng-Kung Cheng
Format: Article
Language:English
Published: Frontiers Media S.A. 2022-12-01
Series:Frontiers in Bioengineering and Biotechnology
Subjects:
Online Access:https://www.frontiersin.org/articles/10.3389/fbioe.2022.967411/full
_version_ 1798004863684050944
author Huizhi Wang
Chaohua Fang
Chaohua Fang
Mingzhu Tao
Qinyi Shi
Kaixin He
Cheng-Kung Cheng
author_facet Huizhi Wang
Chaohua Fang
Chaohua Fang
Mingzhu Tao
Qinyi Shi
Kaixin He
Cheng-Kung Cheng
author_sort Huizhi Wang
collection DOAJ
description Background: Anterior cruciate ligament reconstruction (ACLR) using a generally columnar graft is considered the gold standard for treating anterior cruciate ligament ruptures, but such grafts cannot replicate the geometry and mechanical properties of the native anterior cruciate ligament.Purpose: To evaluate the effectiveness of an innovative hourglass-shaped graft versus a traditional columnar graft for restoring joint stability and graft force, while avoiding notch impingement following anterior cruciate ligament reconstruction.Methods: Finite element models of a human knee were developed to simulate ① An intact state, ② anterior cruciate ligament reconstruction using columnar grafts with different diameters (7.5–12 mm in 0.5 mm increments), ③ anterior cruciate ligament reconstruction using columnar grafts with different Young’s moduli (129.4, 168.0 and 362.2 MPa) and ④ anterior cruciate ligament reconstruction using hourglass-shaped grafts with different Young’s moduli. The knee model was flexed to 30° and loaded with an anterior tibial load of 103 N, internal tibial moment of 7.5 Nm, and valgus tibial moment of 6.9 Nm. The risk of notch impingement, knee stability and graft forces were compared among the different groups.Results: This study found that columnar grafts could not simultaneously restore knee stability in different degree of freedoms (DOFs) and graft force to a level similar to that of the intact knee. The anterior tibial translation and graft force were restored to a near-normal condition when the internal tibial rotation was over-restrained and valgus tibial rotation was lax. A graft diameter of at least 10 mm was needed to restore knee stability and graft force to physiological levels, but such large grafts were found to be at high risk of notch impingement. In contrast, the hourglass-shaped graft was able to simultaneously restore both knee stability and graft force at knee flexion of 30° while also having a much lower risk of impingement.Conclusion: Under knee flexion angle of 30°, an hourglass-shaped graft was better able to restore joint stability and graft force to a near-physiological level than columnar grafts, while also reducing the risk of notch impingement.
first_indexed 2024-04-11T12:30:17Z
format Article
id doaj.art-8bfafac659cc414c8ac51f97575914ec
institution Directory Open Access Journal
issn 2296-4185
language English
last_indexed 2024-04-11T12:30:17Z
publishDate 2022-12-01
publisher Frontiers Media S.A.
record_format Article
series Frontiers in Bioengineering and Biotechnology
spelling doaj.art-8bfafac659cc414c8ac51f97575914ec2022-12-22T04:23:47ZengFrontiers Media S.A.Frontiers in Bioengineering and Biotechnology2296-41852022-12-011010.3389/fbioe.2022.967411967411Hourglass-shaped grafts are superior to conventional grafts for restoring knee stability and graft force at knee flexion angle of 30° following anterior cruciate ligament reconstruction: A finite element analysisHuizhi Wang0Chaohua Fang1Chaohua Fang2Mingzhu Tao3Qinyi Shi4Kaixin He5Cheng-Kung Cheng6Engineering Research Center for Digital Medicine of the Ministry of Education, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China.Engineering Research Center for Digital Medicine of the Ministry of Education, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China.Department of Joint Surgery, The 6th Hospital of Ningbo, Ningbo, Zhejiang, ChinaEngineering Research Center for Digital Medicine of the Ministry of Education, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China.Engineering Research Center for Digital Medicine of the Ministry of Education, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China.Engineering Research Center for Digital Medicine of the Ministry of Education, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China.Engineering Research Center for Digital Medicine of the Ministry of Education, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China.Background: Anterior cruciate ligament reconstruction (ACLR) using a generally columnar graft is considered the gold standard for treating anterior cruciate ligament ruptures, but such grafts cannot replicate the geometry and mechanical properties of the native anterior cruciate ligament.Purpose: To evaluate the effectiveness of an innovative hourglass-shaped graft versus a traditional columnar graft for restoring joint stability and graft force, while avoiding notch impingement following anterior cruciate ligament reconstruction.Methods: Finite element models of a human knee were developed to simulate ① An intact state, ② anterior cruciate ligament reconstruction using columnar grafts with different diameters (7.5–12 mm in 0.5 mm increments), ③ anterior cruciate ligament reconstruction using columnar grafts with different Young’s moduli (129.4, 168.0 and 362.2 MPa) and ④ anterior cruciate ligament reconstruction using hourglass-shaped grafts with different Young’s moduli. The knee model was flexed to 30° and loaded with an anterior tibial load of 103 N, internal tibial moment of 7.5 Nm, and valgus tibial moment of 6.9 Nm. The risk of notch impingement, knee stability and graft forces were compared among the different groups.Results: This study found that columnar grafts could not simultaneously restore knee stability in different degree of freedoms (DOFs) and graft force to a level similar to that of the intact knee. The anterior tibial translation and graft force were restored to a near-normal condition when the internal tibial rotation was over-restrained and valgus tibial rotation was lax. A graft diameter of at least 10 mm was needed to restore knee stability and graft force to physiological levels, but such large grafts were found to be at high risk of notch impingement. In contrast, the hourglass-shaped graft was able to simultaneously restore both knee stability and graft force at knee flexion of 30° while also having a much lower risk of impingement.Conclusion: Under knee flexion angle of 30°, an hourglass-shaped graft was better able to restore joint stability and graft force to a near-physiological level than columnar grafts, while also reducing the risk of notch impingement.https://www.frontiersin.org/articles/10.3389/fbioe.2022.967411/fullACL reconstructiongraft geometrygraft forcenotch impingementknee stability
spellingShingle Huizhi Wang
Chaohua Fang
Chaohua Fang
Mingzhu Tao
Qinyi Shi
Kaixin He
Cheng-Kung Cheng
Hourglass-shaped grafts are superior to conventional grafts for restoring knee stability and graft force at knee flexion angle of 30° following anterior cruciate ligament reconstruction: A finite element analysis
Frontiers in Bioengineering and Biotechnology
ACL reconstruction
graft geometry
graft force
notch impingement
knee stability
title Hourglass-shaped grafts are superior to conventional grafts for restoring knee stability and graft force at knee flexion angle of 30° following anterior cruciate ligament reconstruction: A finite element analysis
title_full Hourglass-shaped grafts are superior to conventional grafts for restoring knee stability and graft force at knee flexion angle of 30° following anterior cruciate ligament reconstruction: A finite element analysis
title_fullStr Hourglass-shaped grafts are superior to conventional grafts for restoring knee stability and graft force at knee flexion angle of 30° following anterior cruciate ligament reconstruction: A finite element analysis
title_full_unstemmed Hourglass-shaped grafts are superior to conventional grafts for restoring knee stability and graft force at knee flexion angle of 30° following anterior cruciate ligament reconstruction: A finite element analysis
title_short Hourglass-shaped grafts are superior to conventional grafts for restoring knee stability and graft force at knee flexion angle of 30° following anterior cruciate ligament reconstruction: A finite element analysis
title_sort hourglass shaped grafts are superior to conventional grafts for restoring knee stability and graft force at knee flexion angle of 30° following anterior cruciate ligament reconstruction a finite element analysis
topic ACL reconstruction
graft geometry
graft force
notch impingement
knee stability
url https://www.frontiersin.org/articles/10.3389/fbioe.2022.967411/full
work_keys_str_mv AT huizhiwang hourglassshapedgraftsaresuperiortoconventionalgraftsforrestoringkneestabilityandgraftforceatkneeflexionangleof30followinganteriorcruciateligamentreconstructionafiniteelementanalysis
AT chaohuafang hourglassshapedgraftsaresuperiortoconventionalgraftsforrestoringkneestabilityandgraftforceatkneeflexionangleof30followinganteriorcruciateligamentreconstructionafiniteelementanalysis
AT chaohuafang hourglassshapedgraftsaresuperiortoconventionalgraftsforrestoringkneestabilityandgraftforceatkneeflexionangleof30followinganteriorcruciateligamentreconstructionafiniteelementanalysis
AT mingzhutao hourglassshapedgraftsaresuperiortoconventionalgraftsforrestoringkneestabilityandgraftforceatkneeflexionangleof30followinganteriorcruciateligamentreconstructionafiniteelementanalysis
AT qinyishi hourglassshapedgraftsaresuperiortoconventionalgraftsforrestoringkneestabilityandgraftforceatkneeflexionangleof30followinganteriorcruciateligamentreconstructionafiniteelementanalysis
AT kaixinhe hourglassshapedgraftsaresuperiortoconventionalgraftsforrestoringkneestabilityandgraftforceatkneeflexionangleof30followinganteriorcruciateligamentreconstructionafiniteelementanalysis
AT chengkungcheng hourglassshapedgraftsaresuperiortoconventionalgraftsforrestoringkneestabilityandgraftforceatkneeflexionangleof30followinganteriorcruciateligamentreconstructionafiniteelementanalysis