Hourglass-shaped grafts are superior to conventional grafts for restoring knee stability and graft force at knee flexion angle of 30° following anterior cruciate ligament reconstruction: A finite element analysis
Background: Anterior cruciate ligament reconstruction (ACLR) using a generally columnar graft is considered the gold standard for treating anterior cruciate ligament ruptures, but such grafts cannot replicate the geometry and mechanical properties of the native anterior cruciate ligament.Purpose: To...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Frontiers Media S.A.
2022-12-01
|
Series: | Frontiers in Bioengineering and Biotechnology |
Subjects: | |
Online Access: | https://www.frontiersin.org/articles/10.3389/fbioe.2022.967411/full |
_version_ | 1798004863684050944 |
---|---|
author | Huizhi Wang Chaohua Fang Chaohua Fang Mingzhu Tao Qinyi Shi Kaixin He Cheng-Kung Cheng |
author_facet | Huizhi Wang Chaohua Fang Chaohua Fang Mingzhu Tao Qinyi Shi Kaixin He Cheng-Kung Cheng |
author_sort | Huizhi Wang |
collection | DOAJ |
description | Background: Anterior cruciate ligament reconstruction (ACLR) using a generally columnar graft is considered the gold standard for treating anterior cruciate ligament ruptures, but such grafts cannot replicate the geometry and mechanical properties of the native anterior cruciate ligament.Purpose: To evaluate the effectiveness of an innovative hourglass-shaped graft versus a traditional columnar graft for restoring joint stability and graft force, while avoiding notch impingement following anterior cruciate ligament reconstruction.Methods: Finite element models of a human knee were developed to simulate ① An intact state, ② anterior cruciate ligament reconstruction using columnar grafts with different diameters (7.5–12 mm in 0.5 mm increments), ③ anterior cruciate ligament reconstruction using columnar grafts with different Young’s moduli (129.4, 168.0 and 362.2 MPa) and ④ anterior cruciate ligament reconstruction using hourglass-shaped grafts with different Young’s moduli. The knee model was flexed to 30° and loaded with an anterior tibial load of 103 N, internal tibial moment of 7.5 Nm, and valgus tibial moment of 6.9 Nm. The risk of notch impingement, knee stability and graft forces were compared among the different groups.Results: This study found that columnar grafts could not simultaneously restore knee stability in different degree of freedoms (DOFs) and graft force to a level similar to that of the intact knee. The anterior tibial translation and graft force were restored to a near-normal condition when the internal tibial rotation was over-restrained and valgus tibial rotation was lax. A graft diameter of at least 10 mm was needed to restore knee stability and graft force to physiological levels, but such large grafts were found to be at high risk of notch impingement. In contrast, the hourglass-shaped graft was able to simultaneously restore both knee stability and graft force at knee flexion of 30° while also having a much lower risk of impingement.Conclusion: Under knee flexion angle of 30°, an hourglass-shaped graft was better able to restore joint stability and graft force to a near-physiological level than columnar grafts, while also reducing the risk of notch impingement. |
first_indexed | 2024-04-11T12:30:17Z |
format | Article |
id | doaj.art-8bfafac659cc414c8ac51f97575914ec |
institution | Directory Open Access Journal |
issn | 2296-4185 |
language | English |
last_indexed | 2024-04-11T12:30:17Z |
publishDate | 2022-12-01 |
publisher | Frontiers Media S.A. |
record_format | Article |
series | Frontiers in Bioengineering and Biotechnology |
spelling | doaj.art-8bfafac659cc414c8ac51f97575914ec2022-12-22T04:23:47ZengFrontiers Media S.A.Frontiers in Bioengineering and Biotechnology2296-41852022-12-011010.3389/fbioe.2022.967411967411Hourglass-shaped grafts are superior to conventional grafts for restoring knee stability and graft force at knee flexion angle of 30° following anterior cruciate ligament reconstruction: A finite element analysisHuizhi Wang0Chaohua Fang1Chaohua Fang2Mingzhu Tao3Qinyi Shi4Kaixin He5Cheng-Kung Cheng6Engineering Research Center for Digital Medicine of the Ministry of Education, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China.Engineering Research Center for Digital Medicine of the Ministry of Education, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China.Department of Joint Surgery, The 6th Hospital of Ningbo, Ningbo, Zhejiang, ChinaEngineering Research Center for Digital Medicine of the Ministry of Education, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China.Engineering Research Center for Digital Medicine of the Ministry of Education, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China.Engineering Research Center for Digital Medicine of the Ministry of Education, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China.Engineering Research Center for Digital Medicine of the Ministry of Education, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China.Background: Anterior cruciate ligament reconstruction (ACLR) using a generally columnar graft is considered the gold standard for treating anterior cruciate ligament ruptures, but such grafts cannot replicate the geometry and mechanical properties of the native anterior cruciate ligament.Purpose: To evaluate the effectiveness of an innovative hourglass-shaped graft versus a traditional columnar graft for restoring joint stability and graft force, while avoiding notch impingement following anterior cruciate ligament reconstruction.Methods: Finite element models of a human knee were developed to simulate ① An intact state, ② anterior cruciate ligament reconstruction using columnar grafts with different diameters (7.5–12 mm in 0.5 mm increments), ③ anterior cruciate ligament reconstruction using columnar grafts with different Young’s moduli (129.4, 168.0 and 362.2 MPa) and ④ anterior cruciate ligament reconstruction using hourglass-shaped grafts with different Young’s moduli. The knee model was flexed to 30° and loaded with an anterior tibial load of 103 N, internal tibial moment of 7.5 Nm, and valgus tibial moment of 6.9 Nm. The risk of notch impingement, knee stability and graft forces were compared among the different groups.Results: This study found that columnar grafts could not simultaneously restore knee stability in different degree of freedoms (DOFs) and graft force to a level similar to that of the intact knee. The anterior tibial translation and graft force were restored to a near-normal condition when the internal tibial rotation was over-restrained and valgus tibial rotation was lax. A graft diameter of at least 10 mm was needed to restore knee stability and graft force to physiological levels, but such large grafts were found to be at high risk of notch impingement. In contrast, the hourglass-shaped graft was able to simultaneously restore both knee stability and graft force at knee flexion of 30° while also having a much lower risk of impingement.Conclusion: Under knee flexion angle of 30°, an hourglass-shaped graft was better able to restore joint stability and graft force to a near-physiological level than columnar grafts, while also reducing the risk of notch impingement.https://www.frontiersin.org/articles/10.3389/fbioe.2022.967411/fullACL reconstructiongraft geometrygraft forcenotch impingementknee stability |
spellingShingle | Huizhi Wang Chaohua Fang Chaohua Fang Mingzhu Tao Qinyi Shi Kaixin He Cheng-Kung Cheng Hourglass-shaped grafts are superior to conventional grafts for restoring knee stability and graft force at knee flexion angle of 30° following anterior cruciate ligament reconstruction: A finite element analysis Frontiers in Bioengineering and Biotechnology ACL reconstruction graft geometry graft force notch impingement knee stability |
title | Hourglass-shaped grafts are superior to conventional grafts for restoring knee stability and graft force at knee flexion angle of 30° following anterior cruciate ligament reconstruction: A finite element analysis |
title_full | Hourglass-shaped grafts are superior to conventional grafts for restoring knee stability and graft force at knee flexion angle of 30° following anterior cruciate ligament reconstruction: A finite element analysis |
title_fullStr | Hourglass-shaped grafts are superior to conventional grafts for restoring knee stability and graft force at knee flexion angle of 30° following anterior cruciate ligament reconstruction: A finite element analysis |
title_full_unstemmed | Hourglass-shaped grafts are superior to conventional grafts for restoring knee stability and graft force at knee flexion angle of 30° following anterior cruciate ligament reconstruction: A finite element analysis |
title_short | Hourglass-shaped grafts are superior to conventional grafts for restoring knee stability and graft force at knee flexion angle of 30° following anterior cruciate ligament reconstruction: A finite element analysis |
title_sort | hourglass shaped grafts are superior to conventional grafts for restoring knee stability and graft force at knee flexion angle of 30° following anterior cruciate ligament reconstruction a finite element analysis |
topic | ACL reconstruction graft geometry graft force notch impingement knee stability |
url | https://www.frontiersin.org/articles/10.3389/fbioe.2022.967411/full |
work_keys_str_mv | AT huizhiwang hourglassshapedgraftsaresuperiortoconventionalgraftsforrestoringkneestabilityandgraftforceatkneeflexionangleof30followinganteriorcruciateligamentreconstructionafiniteelementanalysis AT chaohuafang hourglassshapedgraftsaresuperiortoconventionalgraftsforrestoringkneestabilityandgraftforceatkneeflexionangleof30followinganteriorcruciateligamentreconstructionafiniteelementanalysis AT chaohuafang hourglassshapedgraftsaresuperiortoconventionalgraftsforrestoringkneestabilityandgraftforceatkneeflexionangleof30followinganteriorcruciateligamentreconstructionafiniteelementanalysis AT mingzhutao hourglassshapedgraftsaresuperiortoconventionalgraftsforrestoringkneestabilityandgraftforceatkneeflexionangleof30followinganteriorcruciateligamentreconstructionafiniteelementanalysis AT qinyishi hourglassshapedgraftsaresuperiortoconventionalgraftsforrestoringkneestabilityandgraftforceatkneeflexionangleof30followinganteriorcruciateligamentreconstructionafiniteelementanalysis AT kaixinhe hourglassshapedgraftsaresuperiortoconventionalgraftsforrestoringkneestabilityandgraftforceatkneeflexionangleof30followinganteriorcruciateligamentreconstructionafiniteelementanalysis AT chengkungcheng hourglassshapedgraftsaresuperiortoconventionalgraftsforrestoringkneestabilityandgraftforceatkneeflexionangleof30followinganteriorcruciateligamentreconstructionafiniteelementanalysis |