Experimental study of the effect of slit width and slit spacing on the thermal performance of slit-glazed collectors
An experimental study on the thermal performance of slit-glazed collectors was conducted. Here, glass panes were used as slit glazing cover, and the air was blown continuously through the gaps between them by fan (slit glazing is an uncomplicated and economical process compared to glass perforation)...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
SAGE Publishing
2017-09-01
|
Series: | Advances in Mechanical Engineering |
Online Access: | https://doi.org/10.1177/1687814017728477 |
_version_ | 1819042479456911360 |
---|---|
author | Seyed Mahdi Taheri Mousavi Fuat Egelioglu |
author_facet | Seyed Mahdi Taheri Mousavi Fuat Egelioglu |
author_sort | Seyed Mahdi Taheri Mousavi |
collection | DOAJ |
description | An experimental study on the thermal performance of slit-glazed collectors was conducted. Here, glass panes were used as slit glazing cover, and the air was blown continuously through the gaps between them by fan (slit glazing is an uncomplicated and economical process compared to glass perforation). In this study, the effect of the width of glass panes, the distance between the slits, and mass flow rates were studied on three slit-glazed collectors. A glass pane with the length of 131 cm and thickness 0.4 cm was studied for three different slit widths: 6, 5, and 4 cm. The experiments are conducted with four different gap distances between the glass panes (0.5, 1, 2, and 3 mm) and three air mass flow rates (0.014, 0.022, and 0.029 kg/s). The experimental results indicated that the maximum thermal efficiency of 75% was obtained when the gap distance was 0.5 mm, slit width was 4 cm, and the mass flow rate was 0.029 kg/s. The maximum rise in air temperature was noted as 28°C when the gap distance and slit widths were 0.5 mm and 5 cm, respectively. Hence, the best thermal performance was achieved with the smallest slit width and gap distance parameter values. |
first_indexed | 2024-12-21T09:41:33Z |
format | Article |
id | doaj.art-8c13eca8f6b7499c84a3fb279c6ae361 |
institution | Directory Open Access Journal |
issn | 1687-8140 |
language | English |
last_indexed | 2024-12-21T09:41:33Z |
publishDate | 2017-09-01 |
publisher | SAGE Publishing |
record_format | Article |
series | Advances in Mechanical Engineering |
spelling | doaj.art-8c13eca8f6b7499c84a3fb279c6ae3612022-12-21T19:08:26ZengSAGE PublishingAdvances in Mechanical Engineering1687-81402017-09-01910.1177/1687814017728477Experimental study of the effect of slit width and slit spacing on the thermal performance of slit-glazed collectorsSeyed Mahdi Taheri MousaviFuat EgeliogluAn experimental study on the thermal performance of slit-glazed collectors was conducted. Here, glass panes were used as slit glazing cover, and the air was blown continuously through the gaps between them by fan (slit glazing is an uncomplicated and economical process compared to glass perforation). In this study, the effect of the width of glass panes, the distance between the slits, and mass flow rates were studied on three slit-glazed collectors. A glass pane with the length of 131 cm and thickness 0.4 cm was studied for three different slit widths: 6, 5, and 4 cm. The experiments are conducted with four different gap distances between the glass panes (0.5, 1, 2, and 3 mm) and three air mass flow rates (0.014, 0.022, and 0.029 kg/s). The experimental results indicated that the maximum thermal efficiency of 75% was obtained when the gap distance was 0.5 mm, slit width was 4 cm, and the mass flow rate was 0.029 kg/s. The maximum rise in air temperature was noted as 28°C when the gap distance and slit widths were 0.5 mm and 5 cm, respectively. Hence, the best thermal performance was achieved with the smallest slit width and gap distance parameter values.https://doi.org/10.1177/1687814017728477 |
spellingShingle | Seyed Mahdi Taheri Mousavi Fuat Egelioglu Experimental study of the effect of slit width and slit spacing on the thermal performance of slit-glazed collectors Advances in Mechanical Engineering |
title | Experimental study of the effect of slit width and slit spacing on the thermal performance of slit-glazed collectors |
title_full | Experimental study of the effect of slit width and slit spacing on the thermal performance of slit-glazed collectors |
title_fullStr | Experimental study of the effect of slit width and slit spacing on the thermal performance of slit-glazed collectors |
title_full_unstemmed | Experimental study of the effect of slit width and slit spacing on the thermal performance of slit-glazed collectors |
title_short | Experimental study of the effect of slit width and slit spacing on the thermal performance of slit-glazed collectors |
title_sort | experimental study of the effect of slit width and slit spacing on the thermal performance of slit glazed collectors |
url | https://doi.org/10.1177/1687814017728477 |
work_keys_str_mv | AT seyedmahditaherimousavi experimentalstudyoftheeffectofslitwidthandslitspacingonthethermalperformanceofslitglazedcollectors AT fuategelioglu experimentalstudyoftheeffectofslitwidthandslitspacingonthethermalperformanceofslitglazedcollectors |