Evaluation of Retention Force of Polyetheretherketone (PEEK) and Cast Cobalt-Chromium Circumferential Clasps: A comparative study

Aims: The aim of this in-vitro study was to compare the retention force of Polyetheretherketone (PEEK) and Cobalt-Chromium (Co-Cr) clasps by mechanical cycling test simulating ten years of use. Materials and Methods: 72 clasps samples were fabricated on a standardized e-max upper right first premola...

Full description

Bibliographic Details
Main Authors: Hussein T. Abed, Aliaa W. Al-Omari
Format: Article
Language:Arabic
Published: University of Mosul, College of Dentistry 2022-03-01
Series:Al-Rafidain Dental Journal
Online Access:https://rden.mosuljournals.com/pdf_173006_506a58e5e6890d36c1efa88781cd9838.html
_version_ 1818158735206383616
author Hussein T. Abed
Aliaa W. Al-Omari
author_facet Hussein T. Abed
Aliaa W. Al-Omari
author_sort Hussein T. Abed
collection DOAJ
description Aims: The aim of this in-vitro study was to compare the retention force of Polyetheretherketone (PEEK) and Cobalt-Chromium (Co-Cr) clasps by mechanical cycling test simulating ten years of use. Materials and Methods: 72 clasps samples were fabricated on a standardized e-max upper right first premolar, it is divided into 24 Co-Cr clasps, and 48 PEEK clasps which were subdivided into 24 clasps (2.4mm width), and 24 clasps (3.00mm width).Each group was further subdivided (n=8 clasps) into amounts of abutment undercut 0.25mm, 0.50, and 0.75mm undercuts. Mechanical cycling of each clasp was performed for 15000 times on its specific abutment crown. The retention force of each clasp in newton was measured every 1500 cycles by applying a tensile force using a universal tensile machine. Results: The retention force of Co-Cr clasps was higher significantly than the PEEK clasps retention force for the three undercuts. Deeper undercut showed a significantly higher retention force for both materials. All subgroups (except 0.75mm Co-Cr group) exhibit an increase in retention force after first 1500 cycles followed by gradual decrease till the end of 15000 cycles. Conclusions: The retention force of PEEK clasps with both widths along 15000 cycles of insertion/removal were lower than Co-Cr clasps but still sufficient for clinical use at 050, and 0.75mm undercut but not enough at 0.25mm undercut.
first_indexed 2024-12-11T15:34:48Z
format Article
id doaj.art-8c1a2b60a13e4335beba75aa957bb206
institution Directory Open Access Journal
issn 1812-1217
1998-0345
language Arabic
last_indexed 2024-12-11T15:34:48Z
publishDate 2022-03-01
publisher University of Mosul, College of Dentistry
record_format Article
series Al-Rafidain Dental Journal
spelling doaj.art-8c1a2b60a13e4335beba75aa957bb2062022-12-22T00:59:59ZaraUniversity of Mosul, College of DentistryAl-Rafidain Dental Journal1812-12171998-03452022-03-012211927http://dx.doi.org/10.33899/rdenj.2021.129349.1082Evaluation of Retention Force of Polyetheretherketone (PEEK) and Cast Cobalt-Chromium Circumferential Clasps: A comparative studyHussein T. Abed0Aliaa W. Al-Omari1Ministry of Health- Ninawa Health Directorate, IraqDepartment of Prosthetic Dentistry, College of Dentistry, University of Mosul., IraqAims: The aim of this in-vitro study was to compare the retention force of Polyetheretherketone (PEEK) and Cobalt-Chromium (Co-Cr) clasps by mechanical cycling test simulating ten years of use. Materials and Methods: 72 clasps samples were fabricated on a standardized e-max upper right first premolar, it is divided into 24 Co-Cr clasps, and 48 PEEK clasps which were subdivided into 24 clasps (2.4mm width), and 24 clasps (3.00mm width).Each group was further subdivided (n=8 clasps) into amounts of abutment undercut 0.25mm, 0.50, and 0.75mm undercuts. Mechanical cycling of each clasp was performed for 15000 times on its specific abutment crown. The retention force of each clasp in newton was measured every 1500 cycles by applying a tensile force using a universal tensile machine. Results: The retention force of Co-Cr clasps was higher significantly than the PEEK clasps retention force for the three undercuts. Deeper undercut showed a significantly higher retention force for both materials. All subgroups (except 0.75mm Co-Cr group) exhibit an increase in retention force after first 1500 cycles followed by gradual decrease till the end of 15000 cycles. Conclusions: The retention force of PEEK clasps with both widths along 15000 cycles of insertion/removal were lower than Co-Cr clasps but still sufficient for clinical use at 050, and 0.75mm undercut but not enough at 0.25mm undercut.https://rden.mosuljournals.com/pdf_173006_506a58e5e6890d36c1efa88781cd9838.html
spellingShingle Hussein T. Abed
Aliaa W. Al-Omari
Evaluation of Retention Force of Polyetheretherketone (PEEK) and Cast Cobalt-Chromium Circumferential Clasps: A comparative study
Al-Rafidain Dental Journal
title Evaluation of Retention Force of Polyetheretherketone (PEEK) and Cast Cobalt-Chromium Circumferential Clasps: A comparative study
title_full Evaluation of Retention Force of Polyetheretherketone (PEEK) and Cast Cobalt-Chromium Circumferential Clasps: A comparative study
title_fullStr Evaluation of Retention Force of Polyetheretherketone (PEEK) and Cast Cobalt-Chromium Circumferential Clasps: A comparative study
title_full_unstemmed Evaluation of Retention Force of Polyetheretherketone (PEEK) and Cast Cobalt-Chromium Circumferential Clasps: A comparative study
title_short Evaluation of Retention Force of Polyetheretherketone (PEEK) and Cast Cobalt-Chromium Circumferential Clasps: A comparative study
title_sort evaluation of retention force of polyetheretherketone peek and cast cobalt chromium circumferential clasps a comparative study
url https://rden.mosuljournals.com/pdf_173006_506a58e5e6890d36c1efa88781cd9838.html
work_keys_str_mv AT husseintabed evaluationofretentionforceofpolyetheretherketonepeekandcastcobaltchromiumcircumferentialclaspsacomparativestudy
AT aliaawalomari evaluationofretentionforceofpolyetheretherketonepeekandcastcobaltchromiumcircumferentialclaspsacomparativestudy