Were carried out the selective investigation of the adult patients exposure levels during radiological diagnostic  procedures  with  the  use  of  17  CT  scanners  in  15  medical  organizations  of  Saint-Petersburg  and Leningrad region in 2009–2012. We collected the data on technical parameters...

Full description

Bibliographic Details
Main Authors: A. A. Bratilova, V. Yu. Golikov, S. A. Kalnitsky
Format: Article
Language:English
Published: Saint-Petersburg Research Institute of Radiation Hygiene after Professor P.V. Ramzaev 2015-08-01
Series:Радиационная гигиена
Subjects:
Online Access:https://www.radhyg.ru/jour/article/view/40
_version_ 1797873938869518336
author A. A. Bratilova
V. Yu. Golikov
S. A. Kalnitsky
author_facet A. A. Bratilova
V. Yu. Golikov
S. A. Kalnitsky
author_sort A. A. Bratilova
collection DOAJ
description Were carried out the selective investigation of the adult patients exposure levels during radiological diagnostic  procedures  with  the  use  of  17  CT  scanners  in  15  medical  organizations  of  Saint-Petersburg  and Leningrad region in 2009–2012. We collected the data on technical parameters of the X-ray computed tomography examinations affecting the level of patient exposure. The effective doses were calculated for scanning of different areas of the patient's body (skull, thorax, abdomen and pelvis). Their mean values were in the range from 0,2 mSv to 31 mSv per examination. The highest doses were observed during the investigation of the abdomen and pelvis. Preliminary values of diagnostic reference levels are proposed for medical organizations of Saint-Petersburg andLeningrad region on the basis of investigation results. These values are defined as the 75% quantile in the distribution  of  dose  length  product  values.  Diagnostic  reference  levels  values  obtained  in  the  investigation  are comparable with the corresponding values currently accepted in the foreign medical practice.
first_indexed 2024-04-10T01:24:01Z
format Article
id doaj.art-8c27f245b71848238910bbed2b55e643
institution Directory Open Access Journal
issn 1998-426X
language English
last_indexed 2024-04-10T01:24:01Z
publishDate 2015-08-01
publisher Saint-Petersburg Research Institute of Radiation Hygiene after Professor P.V. Ramzaev
record_format Article
series Радиационная гигиена
spelling doaj.art-8c27f245b71848238910bbed2b55e6432023-03-13T09:47:04ZengSaint-Petersburg Research Institute of Radiation Hygiene after Professor P.V. RamzaevРадиационная гигиена1998-426X2015-08-0173333839EXPOSURE LEVELS OF PATIENTS DURING COMPUTED TOMOGRAPHY IN MEDICAL ORGANIZATIONS OF SAINT-PETERSBURG AND LENINGRAD REGIONA. A. Bratilova0V. Yu. Golikov1S. A. Kalnitsky2Санкт-Петербургский научно-исследовательский институт радиационной гигиены имени профессора П.В. РамзаеваСанкт-Петербургский научно-исследовательский институт радиационной гигиены имени профессора П.В. РамзаеваСанкт-Петербургский научно-исследовательский институт радиационной гигиены имени профессора П.В. РамзаеваWere carried out the selective investigation of the adult patients exposure levels during radiological diagnostic  procedures  with  the  use  of  17  CT  scanners  in  15  medical  organizations  of  Saint-Petersburg  and Leningrad region in 2009–2012. We collected the data on technical parameters of the X-ray computed tomography examinations affecting the level of patient exposure. The effective doses were calculated for scanning of different areas of the patient's body (skull, thorax, abdomen and pelvis). Their mean values were in the range from 0,2 mSv to 31 mSv per examination. The highest doses were observed during the investigation of the abdomen and pelvis. Preliminary values of diagnostic reference levels are proposed for medical organizations of Saint-Petersburg andLeningrad region on the basis of investigation results. These values are defined as the 75% quantile in the distribution  of  dose  length  product  values.  Diagnostic  reference  levels  values  obtained  in  the  investigation  are comparable with the corresponding values currently accepted in the foreign medical practice.https://www.radhyg.ru/jour/article/view/40рентгенологические исследованиякомпьютерная томографияпациентыради-ационная защитапроизведение дозы на длину сканированияэффективная дозареферентные диагно-стические уровни
spellingShingle A. A. Bratilova
V. Yu. Golikov
S. A. Kalnitsky
EXPOSURE LEVELS OF PATIENTS DURING COMPUTED TOMOGRAPHY IN MEDICAL ORGANIZATIONS OF SAINT-PETERSBURG AND LENINGRAD REGION
Радиационная гигиена
рентгенологические исследования
компьютерная томография
пациенты
ради-ационная защита
произведение дозы на длину сканирования
эффективная доза
референтные диагно-стические уровни
title EXPOSURE LEVELS OF PATIENTS DURING COMPUTED TOMOGRAPHY IN MEDICAL ORGANIZATIONS OF SAINT-PETERSBURG AND LENINGRAD REGION
title_full EXPOSURE LEVELS OF PATIENTS DURING COMPUTED TOMOGRAPHY IN MEDICAL ORGANIZATIONS OF SAINT-PETERSBURG AND LENINGRAD REGION
title_fullStr EXPOSURE LEVELS OF PATIENTS DURING COMPUTED TOMOGRAPHY IN MEDICAL ORGANIZATIONS OF SAINT-PETERSBURG AND LENINGRAD REGION
title_full_unstemmed EXPOSURE LEVELS OF PATIENTS DURING COMPUTED TOMOGRAPHY IN MEDICAL ORGANIZATIONS OF SAINT-PETERSBURG AND LENINGRAD REGION
title_short EXPOSURE LEVELS OF PATIENTS DURING COMPUTED TOMOGRAPHY IN MEDICAL ORGANIZATIONS OF SAINT-PETERSBURG AND LENINGRAD REGION
title_sort exposure levels of patients during computed tomography in medical organizations of saint petersburg and leningrad region
topic рентгенологические исследования
компьютерная томография
пациенты
ради-ационная защита
произведение дозы на длину сканирования
эффективная доза
референтные диагно-стические уровни
url https://www.radhyg.ru/jour/article/view/40
work_keys_str_mv AT aabratilova exposurelevelsofpatientsduringcomputedtomographyinmedicalorganizationsofsaintpetersburgandleningradregion
AT vyugolikov exposurelevelsofpatientsduringcomputedtomographyinmedicalorganizationsofsaintpetersburgandleningradregion
AT sakalnitsky exposurelevelsofpatientsduringcomputedtomographyinmedicalorganizationsofsaintpetersburgandleningradregion