Analysis of Bacterial Contamination in Anesthetic Equipments in Operation Room of Vali-E-Asr Hospital of Fasa Efficiency of Disinfection Methods

Background & Objectives: Anesthetic equipments could be one of the factors transmitting infection in a surgical operation. We could be prevent infection transmission to a great extend, by providing efficient methods of disinfection of anesthetic equipments. The purpose of the present research is...

Full description

Bibliographic Details
Main Authors: Abbas Abdollahi, saeid khademi
Format: Article
Language:English
Published: Fasa University of Medical Sciences 2011-09-01
Series:Journal of Advanced Biomedical Sciences
Subjects:
Online Access:http://jabs.fums.ac.ir/article-1-63-en.pdf
_version_ 1797679700989968384
author Abbas Abdollahi
saeid khademi
author_facet Abbas Abdollahi
saeid khademi
author_sort Abbas Abdollahi
collection DOAJ
description Background & Objectives: Anesthetic equipments could be one of the factors transmitting infection in a surgical operation. We could be prevent infection transmission to a great extend, by providing efficient methods of disinfection of anesthetic equipments. The purpose of the present research is to analyze the bacterial contamination in anesthetic equipment in operation rooms of Vali-e-Asr hospital in Fasa city, Fars province, and evaluate the efficiency of the applied disinfection methods. Materials & Methods: In this cross-sectional & analytical study, sampling from anesthetic equipment was done by sterile swap and culture on nutrient media, irregularly and randomly, before and after using and washing tools. Used anesthetic equipment in such operation rooms have been washed with Betadine 7.5% by experts and technicians of anesthetic section and were prepared for the next operation. Results: Total contamination was 2.3% in 210 samples taken. 5 culture items indicated the existence of bacterial contamination, among which 2 contamination cases were observed in nasal airway (coagulase negative Staphylococcus, non pathogen Neisseria), 2 contamination cases in red rubber endotracheal tube (nonpathogen Neisseria and Klebsiella pneumonia) and 1 contamination case in oxygen mask (Escherichia coli). Conclusion: The very low level of contamination (20-85% contamination in anesthetic equipments) in our research is probably due to application of a appropriate disinfection method used by educated personnel in operation rooms. This could have a significant role in decreasing the infection rate in one hand and decreasing expenses and time on the other hand.
first_indexed 2024-03-11T23:18:42Z
format Article
id doaj.art-8ca3038d899d4473afcd5f3ec642bb81
institution Directory Open Access Journal
issn 2228-5105
2783-1523
language English
last_indexed 2024-03-11T23:18:42Z
publishDate 2011-09-01
publisher Fasa University of Medical Sciences
record_format Article
series Journal of Advanced Biomedical Sciences
spelling doaj.art-8ca3038d899d4473afcd5f3ec642bb812023-09-20T21:13:42ZengFasa University of Medical SciencesJournal of Advanced Biomedical Sciences2228-51052783-15232011-09-01121418Analysis of Bacterial Contamination in Anesthetic Equipments in Operation Room of Vali-E-Asr Hospital of Fasa Efficiency of Disinfection MethodsAbbas Abdollahi0saeid khademi1 Background & Objectives: Anesthetic equipments could be one of the factors transmitting infection in a surgical operation. We could be prevent infection transmission to a great extend, by providing efficient methods of disinfection of anesthetic equipments. The purpose of the present research is to analyze the bacterial contamination in anesthetic equipment in operation rooms of Vali-e-Asr hospital in Fasa city, Fars province, and evaluate the efficiency of the applied disinfection methods. Materials & Methods: In this cross-sectional & analytical study, sampling from anesthetic equipment was done by sterile swap and culture on nutrient media, irregularly and randomly, before and after using and washing tools. Used anesthetic equipment in such operation rooms have been washed with Betadine 7.5% by experts and technicians of anesthetic section and were prepared for the next operation. Results: Total contamination was 2.3% in 210 samples taken. 5 culture items indicated the existence of bacterial contamination, among which 2 contamination cases were observed in nasal airway (coagulase negative Staphylococcus, non pathogen Neisseria), 2 contamination cases in red rubber endotracheal tube (nonpathogen Neisseria and Klebsiella pneumonia) and 1 contamination case in oxygen mask (Escherichia coli). Conclusion: The very low level of contamination (20-85% contamination in anesthetic equipments) in our research is probably due to application of a appropriate disinfection method used by educated personnel in operation rooms. This could have a significant role in decreasing the infection rate in one hand and decreasing expenses and time on the other hand.http://jabs.fums.ac.ir/article-1-63-en.pdfhospital infectionanesthetic equipmentdisinfectionbacterial contamination
spellingShingle Abbas Abdollahi
saeid khademi
Analysis of Bacterial Contamination in Anesthetic Equipments in Operation Room of Vali-E-Asr Hospital of Fasa Efficiency of Disinfection Methods
Journal of Advanced Biomedical Sciences
hospital infection
anesthetic equipment
disinfection
bacterial contamination
title Analysis of Bacterial Contamination in Anesthetic Equipments in Operation Room of Vali-E-Asr Hospital of Fasa Efficiency of Disinfection Methods
title_full Analysis of Bacterial Contamination in Anesthetic Equipments in Operation Room of Vali-E-Asr Hospital of Fasa Efficiency of Disinfection Methods
title_fullStr Analysis of Bacterial Contamination in Anesthetic Equipments in Operation Room of Vali-E-Asr Hospital of Fasa Efficiency of Disinfection Methods
title_full_unstemmed Analysis of Bacterial Contamination in Anesthetic Equipments in Operation Room of Vali-E-Asr Hospital of Fasa Efficiency of Disinfection Methods
title_short Analysis of Bacterial Contamination in Anesthetic Equipments in Operation Room of Vali-E-Asr Hospital of Fasa Efficiency of Disinfection Methods
title_sort analysis of bacterial contamination in anesthetic equipments in operation room of vali e asr hospital of fasa efficiency of disinfection methods
topic hospital infection
anesthetic equipment
disinfection
bacterial contamination
url http://jabs.fums.ac.ir/article-1-63-en.pdf
work_keys_str_mv AT abbasabdollahi analysisofbacterialcontaminationinanestheticequipmentsinoperationroomofvalieasrhospitaloffasaefficiencyofdisinfectionmethods
AT saeidkhademi analysisofbacterialcontaminationinanestheticequipmentsinoperationroomofvalieasrhospitaloffasaefficiencyofdisinfectionmethods