Inter-rater Reliability of a Portable Ultrasound for the Quadriceps and Hamstrings Thickness Measurement in Healthy Adults
PURPOSE The purpose of this study was to examine the inter-rater reliability of a portable ultrasound device for measuring the muscle thickness of the quadriceps and hamstrings in healthy subjects. METHODS Thirty-six subjects (20 males, 16 females, age 22.2±2.0 years, mass 67.4±11.3 kg, height 171.7...
Main Authors: | , |
---|---|
Format: | Article |
Language: | Korean |
Published: |
The Korean Society of Exercise Physiology
2020-02-01
|
Series: | 운동과학 |
Subjects: | |
Online Access: | http://www.ksep-es.org/upload/pdf/es-29-1-71.pdf |
_version_ | 1818303911979646976 |
---|---|
author | Soul Cheon Eunwook Chang |
author_facet | Soul Cheon Eunwook Chang |
author_sort | Soul Cheon |
collection | DOAJ |
description | PURPOSE The purpose of this study was to examine the inter-rater reliability of a portable ultrasound device for measuring the muscle thickness of the quadriceps and hamstrings in healthy subjects. METHODS Thirty-six subjects (20 males, 16 females, age 22.2±2.0 years, mass 67.4±11.3 kg, height 171.7±9.6 cm) participated as subjects and two examiners attended. The thickness of the quadriceps was measured in order of rectus femoris (RF), vastus intermedius (VI), vastus lateralis (VL), vastus medialis (VM), and vastus medialis oblique (VMO). The hamstring thickness was measured in order of biceps femoris (BF), semitendinosus (ST), and semimembranosus (SM). Three measurements were taken for each muscle by one examiner. Using image J software, the average thickness was calculated from the measured image. Pearson’s correlation coefficient was used in order to identify inter-rater reliability, and the statistical significance level was set to p<.05. RESULTS Pearson correlation coefficient for inter-examiner reliability of ultrasound showed moderate-to-high level for all assessed muscle. In quadriceps, the values were significantly correlated ranged from 0.62 to 0.90 and in hamstrings the value were relatively low with values of 0.57 to 0.68. CONCLUSIONS The findings of this study indicated that portable ultrasound was a reliable method for measuring the quadriceps and hamstring muscle thickness. Therefore, it could be used as a useful assessment tool in future studies to assess various skeletal muscle thicknesses. |
first_indexed | 2024-12-13T06:02:20Z |
format | Article |
id | doaj.art-8ca6869ce34742debbe5c6a4eb9b8359 |
institution | Directory Open Access Journal |
issn | 1226-1726 2384-0544 |
language | Korean |
last_indexed | 2024-12-13T06:02:20Z |
publishDate | 2020-02-01 |
publisher | The Korean Society of Exercise Physiology |
record_format | Article |
series | 운동과학 |
spelling | doaj.art-8ca6869ce34742debbe5c6a4eb9b83592022-12-21T23:57:19ZkorThe Korean Society of Exercise Physiology운동과학1226-17262384-05442020-02-01291717610.15857/ksep.2020.29.1.71830Inter-rater Reliability of a Portable Ultrasound for the Quadriceps and Hamstrings Thickness Measurement in Healthy AdultsSoul Cheon0Eunwook Chang1Department of Kinesiology, Inha University, Incheon, KoreaDepartment of Kinesiology, Inha University, Incheon, KoreaPURPOSE The purpose of this study was to examine the inter-rater reliability of a portable ultrasound device for measuring the muscle thickness of the quadriceps and hamstrings in healthy subjects. METHODS Thirty-six subjects (20 males, 16 females, age 22.2±2.0 years, mass 67.4±11.3 kg, height 171.7±9.6 cm) participated as subjects and two examiners attended. The thickness of the quadriceps was measured in order of rectus femoris (RF), vastus intermedius (VI), vastus lateralis (VL), vastus medialis (VM), and vastus medialis oblique (VMO). The hamstring thickness was measured in order of biceps femoris (BF), semitendinosus (ST), and semimembranosus (SM). Three measurements were taken for each muscle by one examiner. Using image J software, the average thickness was calculated from the measured image. Pearson’s correlation coefficient was used in order to identify inter-rater reliability, and the statistical significance level was set to p<.05. RESULTS Pearson correlation coefficient for inter-examiner reliability of ultrasound showed moderate-to-high level for all assessed muscle. In quadriceps, the values were significantly correlated ranged from 0.62 to 0.90 and in hamstrings the value were relatively low with values of 0.57 to 0.68. CONCLUSIONS The findings of this study indicated that portable ultrasound was a reliable method for measuring the quadriceps and hamstring muscle thickness. Therefore, it could be used as a useful assessment tool in future studies to assess various skeletal muscle thicknesses.http://www.ksep-es.org/upload/pdf/es-29-1-71.pdfinter-rater reliabilityultrasoundquadricepshamstringsmuscle thickness |
spellingShingle | Soul Cheon Eunwook Chang Inter-rater Reliability of a Portable Ultrasound for the Quadriceps and Hamstrings Thickness Measurement in Healthy Adults 운동과학 inter-rater reliability ultrasound quadriceps hamstrings muscle thickness |
title | Inter-rater Reliability of a Portable Ultrasound for the Quadriceps and Hamstrings Thickness Measurement in Healthy Adults |
title_full | Inter-rater Reliability of a Portable Ultrasound for the Quadriceps and Hamstrings Thickness Measurement in Healthy Adults |
title_fullStr | Inter-rater Reliability of a Portable Ultrasound for the Quadriceps and Hamstrings Thickness Measurement in Healthy Adults |
title_full_unstemmed | Inter-rater Reliability of a Portable Ultrasound for the Quadriceps and Hamstrings Thickness Measurement in Healthy Adults |
title_short | Inter-rater Reliability of a Portable Ultrasound for the Quadriceps and Hamstrings Thickness Measurement in Healthy Adults |
title_sort | inter rater reliability of a portable ultrasound for the quadriceps and hamstrings thickness measurement in healthy adults |
topic | inter-rater reliability ultrasound quadriceps hamstrings muscle thickness |
url | http://www.ksep-es.org/upload/pdf/es-29-1-71.pdf |
work_keys_str_mv | AT soulcheon interraterreliabilityofaportableultrasoundforthequadricepsandhamstringsthicknessmeasurementinhealthyadults AT eunwookchang interraterreliabilityofaportableultrasoundforthequadricepsandhamstringsthicknessmeasurementinhealthyadults |