Multiple immunoassay interference in a patient with falsely elevated calcitonin

SUMMARY Calcitonin (CT) is a diagnostic and follow-up marker of medullary thyroid carcinoma. Heterophile antibodies (HAbs) may interfere during immunometric assay measurements and result in falsely high CT levels and different markers. A 50-year-old female patient was referred to our institution for...

Full description

Bibliographic Details
Main Authors: Mehmet Cagri Unal, Aslihan Cavunt Bayraktar, Tevfik Uslu, Serkan Yener
Format: Article
Language:English
Published: Brazilian Society of Endocrinology and Metabolism 2024-02-01
Series:Archives of Endocrinology and Metabolism
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S2359-39972024000101603&lng=en&tlng=en
_version_ 1797323539818217472
author Mehmet Cagri Unal
Aslihan Cavunt Bayraktar
Tevfik Uslu
Serkan Yener
author_facet Mehmet Cagri Unal
Aslihan Cavunt Bayraktar
Tevfik Uslu
Serkan Yener
author_sort Mehmet Cagri Unal
collection DOAJ
description SUMMARY Calcitonin (CT) is a diagnostic and follow-up marker of medullary thyroid carcinoma. Heterophile antibodies (HAbs) may interfere during immunometric assay measurements and result in falsely high CT levels and different markers. A 50-year-old female patient was referred to our institution for elevated CT levels (3,199 pg/mL [0-11,5]). Physical examination and thyroid ultrasonography show no thyroid nodules. Because of the discrepancy between the clinical picture and the laboratory results, various markers and hormones were examined to determine whether there was any interference in the immunometric assay. Thyroglobulin (Tg) and Adrenocorticotropic hormone (ACTH) levels were also found inaccurately elevated. After precipitation with polyethylene glycol, CT, Tg, and ACTH levels markedly decreased, showing macro-aggregates. Also, serial dilutions showed non-linearity in plasma concentrations. Additionally, CT samples were pretreated with a heterophilic blocking tube before measuring, and the CT level decreased to < 0.1 pg/mL, suggesting a HAb presence. Immunoassay interference should be considered when conflicting laboratory data are observed. This may help reduce the amount of unnecessary laboratory and imaging studies and prevent patients from complex diagnostic procedures.
first_indexed 2024-03-08T05:30:04Z
format Article
id doaj.art-8cf2a3a95b484cdf92f4f6bb983cd6fc
institution Directory Open Access Journal
issn 2359-4292
language English
last_indexed 2024-03-08T05:30:04Z
publishDate 2024-02-01
publisher Brazilian Society of Endocrinology and Metabolism
record_format Article
series Archives of Endocrinology and Metabolism
spelling doaj.art-8cf2a3a95b484cdf92f4f6bb983cd6fc2024-02-06T07:43:11ZengBrazilian Society of Endocrinology and MetabolismArchives of Endocrinology and Metabolism2359-42922024-02-016810.20945/2359-4292-2023-0074Multiple immunoassay interference in a patient with falsely elevated calcitoninMehmet Cagri Unalhttps://orcid.org/0000-0001-8000-5220Aslihan Cavunt Bayraktarhttps://orcid.org/0000-0001-9966-5122Tevfik Usluhttps://orcid.org/0009-0008-5431-4263Serkan Yenerhttps://orcid.org/0000-0003-0427-735XSUMMARY Calcitonin (CT) is a diagnostic and follow-up marker of medullary thyroid carcinoma. Heterophile antibodies (HAbs) may interfere during immunometric assay measurements and result in falsely high CT levels and different markers. A 50-year-old female patient was referred to our institution for elevated CT levels (3,199 pg/mL [0-11,5]). Physical examination and thyroid ultrasonography show no thyroid nodules. Because of the discrepancy between the clinical picture and the laboratory results, various markers and hormones were examined to determine whether there was any interference in the immunometric assay. Thyroglobulin (Tg) and Adrenocorticotropic hormone (ACTH) levels were also found inaccurately elevated. After precipitation with polyethylene glycol, CT, Tg, and ACTH levels markedly decreased, showing macro-aggregates. Also, serial dilutions showed non-linearity in plasma concentrations. Additionally, CT samples were pretreated with a heterophilic blocking tube before measuring, and the CT level decreased to < 0.1 pg/mL, suggesting a HAb presence. Immunoassay interference should be considered when conflicting laboratory data are observed. This may help reduce the amount of unnecessary laboratory and imaging studies and prevent patients from complex diagnostic procedures.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S2359-39972024000101603&lng=en&tlng=en
spellingShingle Mehmet Cagri Unal
Aslihan Cavunt Bayraktar
Tevfik Uslu
Serkan Yener
Multiple immunoassay interference in a patient with falsely elevated calcitonin
Archives of Endocrinology and Metabolism
title Multiple immunoassay interference in a patient with falsely elevated calcitonin
title_full Multiple immunoassay interference in a patient with falsely elevated calcitonin
title_fullStr Multiple immunoassay interference in a patient with falsely elevated calcitonin
title_full_unstemmed Multiple immunoassay interference in a patient with falsely elevated calcitonin
title_short Multiple immunoassay interference in a patient with falsely elevated calcitonin
title_sort multiple immunoassay interference in a patient with falsely elevated calcitonin
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S2359-39972024000101603&lng=en&tlng=en
work_keys_str_mv AT mehmetcagriunal multipleimmunoassayinterferenceinapatientwithfalselyelevatedcalcitonin
AT aslihancavuntbayraktar multipleimmunoassayinterferenceinapatientwithfalselyelevatedcalcitonin
AT tevfikuslu multipleimmunoassayinterferenceinapatientwithfalselyelevatedcalcitonin
AT serkanyener multipleimmunoassayinterferenceinapatientwithfalselyelevatedcalcitonin