Comparison of Pattern Electroretinography and Optical Coherence Tomography Parameters in Patients with Primary Open-Angle Glaucoma and Ocular Hypertension
Objectives: To investigate the correlation of visual field (VF), pattern electroretinography (PERG) and Fourier domain optical coherence tomography (FD-OCT) results in patients with ocular hypertension (OHT) and early primary open-angle glaucoma (POAG). Materials and Methods: The study included 72...
Main Authors: | , , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Galenos Yayinevi
2015-12-01
|
Series: | Türk Oftalmoloji Dergisi |
Subjects: | |
Online Access: | http://www.oftalmoloji.org/article_9919/Comparison-Of-Pattern-Electroretinography-And-Optical-Coherence-Tomography-Parameters-In-Patients-With-Primary-Open-angle-Glaucoma-And-Ocular-Hypertension |
_version_ | 1828025297434312704 |
---|---|
author | Semra Tiryaki Demir Mehmet Ersin Oba Ezgi Tuna Erdoğan Mahmut Odabaşı Ayşe Burcu Dirim Mehmet Demir Efe Can Orhan Kara Selam Yekta Şendül |
author_facet | Semra Tiryaki Demir Mehmet Ersin Oba Ezgi Tuna Erdoğan Mahmut Odabaşı Ayşe Burcu Dirim Mehmet Demir Efe Can Orhan Kara Selam Yekta Şendül |
author_sort | Semra Tiryaki Demir |
collection | DOAJ |
description | Objectives: To investigate the correlation of visual field (VF), pattern electroretinography (PERG) and Fourier domain optical coherence tomography (FD-OCT) results in patients with ocular hypertension (OHT) and early primary open-angle glaucoma (POAG).
Materials and Methods: The study included 72 eyes of 37 patients with early POAG, 76 eyes of 38 patients with OHT, and 60 eyes of 30 controls. All subjects underwent full ophthalmologic examination, VF assessment with 24-2 Humphrey standard automated perimetry (Swedish Interactive Thresholding Algorithm (SITA)-Standard), retinal nerve fiber layer (RNFL) and ganglion cell complex (GCC) thickness measurement with FD-OCT, and PERG P50 and N95 wave latency and amplitude measurements with electroretinography (Nihon Kohden).
Results: With the exception of the nasal quadrant, all GCC parameters and RNFL results were significantly lower in the POAG group compared to the OHT and control groups. There was no statistically significant difference between the OHT and control group. PERG amplitudes were lower in the POAG and OHT groups than in the control group. Reduction in N95 amplitude was greater than that of P50 amplitude. No difference was detected in PERG latencies among groups. GCC was significantly correlated with VF and RNFL in the POAG group.
Conclusion: Significant thinning of the GCC and RNFL occurs in addition to VF pathologies in patients with early POAG, and these examinations should be concomitantly evaluated. During diagnostic assessment of patients with early POAG, GCC and RNFL analysis by FD-OCT are highly effective. GCC is as reliable as RNLF in the early diagnosis of glaucoma and there is a highly significant correlation between them. Dysfunction of ganglion cells in patients with OHT may be detected earlier using PERG amplitude analysis. |
first_indexed | 2024-04-10T12:58:17Z |
format | Article |
id | doaj.art-8cfbfd885c174330989368bb419c7b35 |
institution | Directory Open Access Journal |
issn | 1300-0659 2147-2661 |
language | English |
last_indexed | 2024-04-10T12:58:17Z |
publishDate | 2015-12-01 |
publisher | Galenos Yayinevi |
record_format | Article |
series | Türk Oftalmoloji Dergisi |
spelling | doaj.art-8cfbfd885c174330989368bb419c7b352023-02-15T16:13:19ZengGalenos YayineviTürk Oftalmoloji Dergisi1300-06592147-26612015-12-0145622923410.4274/tjo.39260Comparison of Pattern Electroretinography and Optical Coherence Tomography Parameters in Patients with Primary Open-Angle Glaucoma and Ocular HypertensionSemra Tiryaki Demir0Mehmet Ersin Oba1Ezgi Tuna Erdoğan2Mahmut Odabaşı3Ayşe Burcu Dirim4Mehmet Demir5Efe Can6Orhan Kara7Selam Yekta Şendül8Şişli Etfal Training and Research Hospital, Clinic of Ophthalmology, İstanbul, TurkeyKafkas University Faculty of Medicine, Department of Ophthalmology, Kars, Turkeyİstanbul University İstanbul Faculty of Medicine, Department of Physiology, İstanbul, TurkeyMedipol University Faculty of Medicine, Department of Ophthalmology, İstanbul, TurkeyŞişli Etfal Training and Research Hospital, Clinic of Ophthalmology, İstanbul, TurkeyŞişli Etfal Training and Research Hospital, Clinic of Ophthalmology, İstanbul, TurkeyŞişli Etfal Training and Research Hospital, Clinic of Ophthalmology, İstanbul, TurkeyŞişli Etfal Training and Research Hospital, Clinic of Ophthalmology, İstanbul, TurkeyŞişli Etfal Training and Research Hospital, Clinic of Ophthalmology, İstanbul, TurkeyObjectives: To investigate the correlation of visual field (VF), pattern electroretinography (PERG) and Fourier domain optical coherence tomography (FD-OCT) results in patients with ocular hypertension (OHT) and early primary open-angle glaucoma (POAG). Materials and Methods: The study included 72 eyes of 37 patients with early POAG, 76 eyes of 38 patients with OHT, and 60 eyes of 30 controls. All subjects underwent full ophthalmologic examination, VF assessment with 24-2 Humphrey standard automated perimetry (Swedish Interactive Thresholding Algorithm (SITA)-Standard), retinal nerve fiber layer (RNFL) and ganglion cell complex (GCC) thickness measurement with FD-OCT, and PERG P50 and N95 wave latency and amplitude measurements with electroretinography (Nihon Kohden). Results: With the exception of the nasal quadrant, all GCC parameters and RNFL results were significantly lower in the POAG group compared to the OHT and control groups. There was no statistically significant difference between the OHT and control group. PERG amplitudes were lower in the POAG and OHT groups than in the control group. Reduction in N95 amplitude was greater than that of P50 amplitude. No difference was detected in PERG latencies among groups. GCC was significantly correlated with VF and RNFL in the POAG group. Conclusion: Significant thinning of the GCC and RNFL occurs in addition to VF pathologies in patients with early POAG, and these examinations should be concomitantly evaluated. During diagnostic assessment of patients with early POAG, GCC and RNFL analysis by FD-OCT are highly effective. GCC is as reliable as RNLF in the early diagnosis of glaucoma and there is a highly significant correlation between them. Dysfunction of ganglion cells in patients with OHT may be detected earlier using PERG amplitude analysis.http://www.oftalmoloji.org/article_9919/Comparison-Of-Pattern-Electroretinography-And-Optical-Coherence-Tomography-Parameters-In-Patients-With-Primary-Open-angle-Glaucoma-And-Ocular-HypertensionPrimary open-angle glaucomaocular hypertensionretinal nerve fiber layerganglion cell complexpattern electroretinogram |
spellingShingle | Semra Tiryaki Demir Mehmet Ersin Oba Ezgi Tuna Erdoğan Mahmut Odabaşı Ayşe Burcu Dirim Mehmet Demir Efe Can Orhan Kara Selam Yekta Şendül Comparison of Pattern Electroretinography and Optical Coherence Tomography Parameters in Patients with Primary Open-Angle Glaucoma and Ocular Hypertension Türk Oftalmoloji Dergisi Primary open-angle glaucoma ocular hypertension retinal nerve fiber layer ganglion cell complex pattern electroretinogram |
title | Comparison of Pattern Electroretinography and Optical Coherence Tomography Parameters in Patients with Primary Open-Angle Glaucoma and Ocular Hypertension |
title_full | Comparison of Pattern Electroretinography and Optical Coherence Tomography Parameters in Patients with Primary Open-Angle Glaucoma and Ocular Hypertension |
title_fullStr | Comparison of Pattern Electroretinography and Optical Coherence Tomography Parameters in Patients with Primary Open-Angle Glaucoma and Ocular Hypertension |
title_full_unstemmed | Comparison of Pattern Electroretinography and Optical Coherence Tomography Parameters in Patients with Primary Open-Angle Glaucoma and Ocular Hypertension |
title_short | Comparison of Pattern Electroretinography and Optical Coherence Tomography Parameters in Patients with Primary Open-Angle Glaucoma and Ocular Hypertension |
title_sort | comparison of pattern electroretinography and optical coherence tomography parameters in patients with primary open angle glaucoma and ocular hypertension |
topic | Primary open-angle glaucoma ocular hypertension retinal nerve fiber layer ganglion cell complex pattern electroretinogram |
url | http://www.oftalmoloji.org/article_9919/Comparison-Of-Pattern-Electroretinography-And-Optical-Coherence-Tomography-Parameters-In-Patients-With-Primary-Open-angle-Glaucoma-And-Ocular-Hypertension |
work_keys_str_mv | AT semratiryakidemir comparisonofpatternelectroretinographyandopticalcoherencetomographyparametersinpatientswithprimaryopenangleglaucomaandocularhypertension AT mehmetersinoba comparisonofpatternelectroretinographyandopticalcoherencetomographyparametersinpatientswithprimaryopenangleglaucomaandocularhypertension AT ezgitunaerdogan comparisonofpatternelectroretinographyandopticalcoherencetomographyparametersinpatientswithprimaryopenangleglaucomaandocularhypertension AT mahmutodabası comparisonofpatternelectroretinographyandopticalcoherencetomographyparametersinpatientswithprimaryopenangleglaucomaandocularhypertension AT ayseburcudirim comparisonofpatternelectroretinographyandopticalcoherencetomographyparametersinpatientswithprimaryopenangleglaucomaandocularhypertension AT mehmetdemir comparisonofpatternelectroretinographyandopticalcoherencetomographyparametersinpatientswithprimaryopenangleglaucomaandocularhypertension AT efecan comparisonofpatternelectroretinographyandopticalcoherencetomographyparametersinpatientswithprimaryopenangleglaucomaandocularhypertension AT orhankara comparisonofpatternelectroretinographyandopticalcoherencetomographyparametersinpatientswithprimaryopenangleglaucomaandocularhypertension AT selamyektasendul comparisonofpatternelectroretinographyandopticalcoherencetomographyparametersinpatientswithprimaryopenangleglaucomaandocularhypertension |