Research on Droplets Deposition Characteristics of Anti-Drift Spray Device with Multi-Airflow Synergy Based on CFD Simulation

With the increase in orchard areas and the transfer of rural labor, various air-assisted sprayers have been widely used in China. However, the problem of off-target drift still exists, which has caused pesticide waste and environmental pollution. In order to improve the droplet deposition in the can...

Full description

Bibliographic Details
Main Authors: Guiju Fan, Siyu Wang, Peng Bai, Dongwei Wang, Wenjie Shi, Chengqiang Niu
Format: Article
Language:English
Published: MDPI AG 2022-07-01
Series:Applied Sciences
Subjects:
Online Access:https://www.mdpi.com/2076-3417/12/14/7082
_version_ 1827598090653138944
author Guiju Fan
Siyu Wang
Peng Bai
Dongwei Wang
Wenjie Shi
Chengqiang Niu
author_facet Guiju Fan
Siyu Wang
Peng Bai
Dongwei Wang
Wenjie Shi
Chengqiang Niu
author_sort Guiju Fan
collection DOAJ
description With the increase in orchard areas and the transfer of rural labor, various air-assisted sprayers have been widely used in China. However, the problem of off-target drift still exists, which has caused pesticide waste and environmental pollution. In order to improve the droplet deposition in the canopy of fruit trees, a V-shaped anti-drift spray device with multi-airflow synergy was designed in this paper. A droplet spatial motion model was constructed, and the anti-drift mechanism of multi-airflow synergy was clarified based on particle dynamics analysis. The influences of spray pressure and V-shaped wind speed on droplet movement were investigated by Matlab, and the experimental results showed that the machine’s anti-drift effect was better when the V-shaped wind speed ranged from 15 m/s to 25 m/s. According to modern orchards with low root stock in a high-density planting, a simulation model of the flow field between the spray device and the fruit trees canopy was established by the method of computational fluid mechanics (CFD). By considering crosswind speed, V-shaped wind speed, and spray pressure, three-level simulation experiments of droplet deposition were designed for each factor using a partial multivariate orthogonal regression method. The influence of V-shaped wind speed on the droplets’ spatial distribution was analyzed, and the prediction model of the drift distance of the droplets’ deposition center was established. The simulation results showed that the three factors had a significant influence on the droplets’ deposition characteristics, and the degree from big to small was V-shaped wind speed, crosswind speed, and spray pressure. The fitting degree of the prediction model was high, and the correlation coefficient was 0.998. The anti-drift experiments of the machine were carried out, and the results showed that when the crosswind speed, the spray pressure, and V-shaped wind speed were 2.2 m/s, 0.52 MPa, and 20.8 m/s, respectively, the droplet drift rate was 29.2% lower than that of single-airflow. The drift distance of the droplets deposition center was 5.0 cm, which was consistent with the prediction model. The research can provide a basis for the design and parameters optimization of the similar sprayers used in modern orchards with low root stock in a high-density planting.
first_indexed 2024-03-09T03:44:36Z
format Article
id doaj.art-8d0768471b64423885ed6edb31cd8b4d
institution Directory Open Access Journal
issn 2076-3417
language English
last_indexed 2024-03-09T03:44:36Z
publishDate 2022-07-01
publisher MDPI AG
record_format Article
series Applied Sciences
spelling doaj.art-8d0768471b64423885ed6edb31cd8b4d2023-12-03T14:36:15ZengMDPI AGApplied Sciences2076-34172022-07-011214708210.3390/app12147082Research on Droplets Deposition Characteristics of Anti-Drift Spray Device with Multi-Airflow Synergy Based on CFD SimulationGuiju Fan0Siyu Wang1Peng Bai2Dongwei Wang3Wenjie Shi4Chengqiang Niu5College of Mechanical and Electrical Engineering, Shandong Agricultural University, Taian 271018, ChinaCollege of Mechanical and Electrical Engineering, Shandong Agricultural University, Taian 271018, ChinaMining Training Center, Shandong University of Science and Technology, Taian 271018, ChinaCollege of Mechanical and Electrical Engineering, Qingdao Agricultural University, Qingdao 266109, ChinaCollege of Mechanical and Electrical Engineering, Shandong Agricultural University, Taian 271018, ChinaCollege of Engineering, Huazhong Agricultural University, Wuhan 430070, ChinaWith the increase in orchard areas and the transfer of rural labor, various air-assisted sprayers have been widely used in China. However, the problem of off-target drift still exists, which has caused pesticide waste and environmental pollution. In order to improve the droplet deposition in the canopy of fruit trees, a V-shaped anti-drift spray device with multi-airflow synergy was designed in this paper. A droplet spatial motion model was constructed, and the anti-drift mechanism of multi-airflow synergy was clarified based on particle dynamics analysis. The influences of spray pressure and V-shaped wind speed on droplet movement were investigated by Matlab, and the experimental results showed that the machine’s anti-drift effect was better when the V-shaped wind speed ranged from 15 m/s to 25 m/s. According to modern orchards with low root stock in a high-density planting, a simulation model of the flow field between the spray device and the fruit trees canopy was established by the method of computational fluid mechanics (CFD). By considering crosswind speed, V-shaped wind speed, and spray pressure, three-level simulation experiments of droplet deposition were designed for each factor using a partial multivariate orthogonal regression method. The influence of V-shaped wind speed on the droplets’ spatial distribution was analyzed, and the prediction model of the drift distance of the droplets’ deposition center was established. The simulation results showed that the three factors had a significant influence on the droplets’ deposition characteristics, and the degree from big to small was V-shaped wind speed, crosswind speed, and spray pressure. The fitting degree of the prediction model was high, and the correlation coefficient was 0.998. The anti-drift experiments of the machine were carried out, and the results showed that when the crosswind speed, the spray pressure, and V-shaped wind speed were 2.2 m/s, 0.52 MPa, and 20.8 m/s, respectively, the droplet drift rate was 29.2% lower than that of single-airflow. The drift distance of the droplets deposition center was 5.0 cm, which was consistent with the prediction model. The research can provide a basis for the design and parameters optimization of the similar sprayers used in modern orchards with low root stock in a high-density planting.https://www.mdpi.com/2076-3417/12/14/7082orchard sprayermulti-flow synergyanti-drift sprayfluent DPMdroplet deposition
spellingShingle Guiju Fan
Siyu Wang
Peng Bai
Dongwei Wang
Wenjie Shi
Chengqiang Niu
Research on Droplets Deposition Characteristics of Anti-Drift Spray Device with Multi-Airflow Synergy Based on CFD Simulation
Applied Sciences
orchard sprayer
multi-flow synergy
anti-drift spray
fluent DPM
droplet deposition
title Research on Droplets Deposition Characteristics of Anti-Drift Spray Device with Multi-Airflow Synergy Based on CFD Simulation
title_full Research on Droplets Deposition Characteristics of Anti-Drift Spray Device with Multi-Airflow Synergy Based on CFD Simulation
title_fullStr Research on Droplets Deposition Characteristics of Anti-Drift Spray Device with Multi-Airflow Synergy Based on CFD Simulation
title_full_unstemmed Research on Droplets Deposition Characteristics of Anti-Drift Spray Device with Multi-Airflow Synergy Based on CFD Simulation
title_short Research on Droplets Deposition Characteristics of Anti-Drift Spray Device with Multi-Airflow Synergy Based on CFD Simulation
title_sort research on droplets deposition characteristics of anti drift spray device with multi airflow synergy based on cfd simulation
topic orchard sprayer
multi-flow synergy
anti-drift spray
fluent DPM
droplet deposition
url https://www.mdpi.com/2076-3417/12/14/7082
work_keys_str_mv AT guijufan researchondropletsdepositioncharacteristicsofantidriftspraydevicewithmultiairflowsynergybasedoncfdsimulation
AT siyuwang researchondropletsdepositioncharacteristicsofantidriftspraydevicewithmultiairflowsynergybasedoncfdsimulation
AT pengbai researchondropletsdepositioncharacteristicsofantidriftspraydevicewithmultiairflowsynergybasedoncfdsimulation
AT dongweiwang researchondropletsdepositioncharacteristicsofantidriftspraydevicewithmultiairflowsynergybasedoncfdsimulation
AT wenjieshi researchondropletsdepositioncharacteristicsofantidriftspraydevicewithmultiairflowsynergybasedoncfdsimulation
AT chengqiangniu researchondropletsdepositioncharacteristicsofantidriftspraydevicewithmultiairflowsynergybasedoncfdsimulation