Detecção de Escherichia coli O157:H7 inoculada experimentalmente em amostras de leite cru por método convencional e PCR multiplex Detection of E. coli O157:H7 experimentally inoculated in raw milk samples by conventional method and multiplex PCR

Padronizou-se um método de reação em cadeia da polimerase (PCR) multiplex para detecção de Escherichia coli O157:H7 e avaliou-se a eficiência da PCR e de um método de cultivo convencional em placas na detecção desse patógeno experimentalmente adicionado em leite estéril e em leite cru com baixa cont...

Full description

Bibliographic Details
Main Authors: P.M. Garcia, E.F. Arcuri, M.A.V.P. Brito, C.C. Lange, J.R.F. Brito, M.M.O.P. Cerqueira
Format: Article
Language:English
Published: Universidade Federal de Minas Gerais 2008-10-01
Series:Arquivo Brasileiro de Medicina Veterinária e Zootecnia
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0102-09352008000500029
_version_ 1819065777487085568
author P.M. Garcia
E.F. Arcuri
M.A.V.P. Brito
C.C. Lange
J.R.F. Brito
M.M.O.P. Cerqueira
author_facet P.M. Garcia
E.F. Arcuri
M.A.V.P. Brito
C.C. Lange
J.R.F. Brito
M.M.O.P. Cerqueira
author_sort P.M. Garcia
collection DOAJ
description Padronizou-se um método de reação em cadeia da polimerase (PCR) multiplex para detecção de Escherichia coli O157:H7 e avaliou-se a eficiência da PCR e de um método de cultivo convencional em placas na detecção desse patógeno experimentalmente adicionado em leite estéril e em leite cru com baixa contagem bacteriana total (média de 4,01 x 10³ UFC/ml) e com alta contagem bacteriana (média de 2,10 x 10(6) UFC/ml). Foram padronizadas duas reações de PCR com o uso dos primers: "A" (RfbF; RfbR e FLICh7F/FLICh7R) e "B" (SLT-IF/SLTIR e SLT-IIF/SLT-IIR). A detecção de E. coli O157:H7 (1UFC/ml) a partir do leite estéril e do leite cru com baixa contaminação bacteriana foi possível quando se utilizou o método de contagem em placas e a PCR. A sensibilidade dos dois métodos foi menor quando se testou o leite cru com alta contaminação microbiana, sendo o método convencional mais sensível. Os resultados indicam que a presença de outros microrganismos, em alta quantidade no leite, dificulta a detecção de E. coli O157:H7 pelos métodos utilizados.<br>This experiment was carried out in order to evaluate the effect of the raw milk bacterial count on the efficiency of a multiplex polymerase chain reaction and a conventional plate count method for detection of Escherichia coli O157:H7. This pathogen was experimentally inoculated into sterile milk, raw milk with low bacterial count (count mean of 4.01 x 10³ cfu/ml) and, raw milk with high bacterial count (mean 2.10 x 10(6) cfu/ml). Two protocols of PCR were standardized using primers "A" (Rfbf and Rfbr and FLICh7F/FLICh7R) and "B" (SLT-IF/SLTIR and SLT-IIF/SLT-IIR). Both conventional plate count and PCR methods were able to detect the presence of E. coli O157:H7 in either sterile milk or raw milk with low bacterial count initially inoculated with 1cfu of E. coli O157:H7 per ml. The sensibility of both methods for high-contaminated raw milk samples was lower, being the conventional approach more sensitive. These results indicate that high bacterial count in raw milk can affect E. coli O157:H7 detection.
first_indexed 2024-12-21T15:51:51Z
format Article
id doaj.art-8d07a95cf1a44910a256e4fa2a119a52
institution Directory Open Access Journal
issn 0102-0935
1678-4162
language English
last_indexed 2024-12-21T15:51:51Z
publishDate 2008-10-01
publisher Universidade Federal de Minas Gerais
record_format Article
series Arquivo Brasileiro de Medicina Veterinária e Zootecnia
spelling doaj.art-8d07a95cf1a44910a256e4fa2a119a522022-12-21T18:58:12ZengUniversidade Federal de Minas GeraisArquivo Brasileiro de Medicina Veterinária e Zootecnia0102-09351678-41622008-10-016051241124910.1590/S0102-09352008000500029Detecção de Escherichia coli O157:H7 inoculada experimentalmente em amostras de leite cru por método convencional e PCR multiplex Detection of E. coli O157:H7 experimentally inoculated in raw milk samples by conventional method and multiplex PCRP.M. GarciaE.F. ArcuriM.A.V.P. BritoC.C. LangeJ.R.F. BritoM.M.O.P. CerqueiraPadronizou-se um método de reação em cadeia da polimerase (PCR) multiplex para detecção de Escherichia coli O157:H7 e avaliou-se a eficiência da PCR e de um método de cultivo convencional em placas na detecção desse patógeno experimentalmente adicionado em leite estéril e em leite cru com baixa contagem bacteriana total (média de 4,01 x 10³ UFC/ml) e com alta contagem bacteriana (média de 2,10 x 10(6) UFC/ml). Foram padronizadas duas reações de PCR com o uso dos primers: "A" (RfbF; RfbR e FLICh7F/FLICh7R) e "B" (SLT-IF/SLTIR e SLT-IIF/SLT-IIR). A detecção de E. coli O157:H7 (1UFC/ml) a partir do leite estéril e do leite cru com baixa contaminação bacteriana foi possível quando se utilizou o método de contagem em placas e a PCR. A sensibilidade dos dois métodos foi menor quando se testou o leite cru com alta contaminação microbiana, sendo o método convencional mais sensível. Os resultados indicam que a presença de outros microrganismos, em alta quantidade no leite, dificulta a detecção de E. coli O157:H7 pelos métodos utilizados.<br>This experiment was carried out in order to evaluate the effect of the raw milk bacterial count on the efficiency of a multiplex polymerase chain reaction and a conventional plate count method for detection of Escherichia coli O157:H7. This pathogen was experimentally inoculated into sterile milk, raw milk with low bacterial count (count mean of 4.01 x 10³ cfu/ml) and, raw milk with high bacterial count (mean 2.10 x 10(6) cfu/ml). Two protocols of PCR were standardized using primers "A" (Rfbf and Rfbr and FLICh7F/FLICh7R) and "B" (SLT-IF/SLTIR and SLT-IIF/SLT-IIR). Both conventional plate count and PCR methods were able to detect the presence of E. coli O157:H7 in either sterile milk or raw milk with low bacterial count initially inoculated with 1cfu of E. coli O157:H7 per ml. The sensibility of both methods for high-contaminated raw milk samples was lower, being the conventional approach more sensitive. These results indicate that high bacterial count in raw milk can affect E. coli O157:H7 detection.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0102-09352008000500029PCR multiplexE. coli O157:H7antígeno O157antígeno H7genes para toxina tipo-shigaPCR multiplexE. coli O157:H7O157 antigenH7 antigenshiga-like toxin genes
spellingShingle P.M. Garcia
E.F. Arcuri
M.A.V.P. Brito
C.C. Lange
J.R.F. Brito
M.M.O.P. Cerqueira
Detecção de Escherichia coli O157:H7 inoculada experimentalmente em amostras de leite cru por método convencional e PCR multiplex Detection of E. coli O157:H7 experimentally inoculated in raw milk samples by conventional method and multiplex PCR
Arquivo Brasileiro de Medicina Veterinária e Zootecnia
PCR multiplex
E. coli O157:H7
antígeno O157
antígeno H7
genes para toxina tipo-shiga
PCR multiplex
E. coli O157:H7
O157 antigen
H7 antigen
shiga-like toxin genes
title Detecção de Escherichia coli O157:H7 inoculada experimentalmente em amostras de leite cru por método convencional e PCR multiplex Detection of E. coli O157:H7 experimentally inoculated in raw milk samples by conventional method and multiplex PCR
title_full Detecção de Escherichia coli O157:H7 inoculada experimentalmente em amostras de leite cru por método convencional e PCR multiplex Detection of E. coli O157:H7 experimentally inoculated in raw milk samples by conventional method and multiplex PCR
title_fullStr Detecção de Escherichia coli O157:H7 inoculada experimentalmente em amostras de leite cru por método convencional e PCR multiplex Detection of E. coli O157:H7 experimentally inoculated in raw milk samples by conventional method and multiplex PCR
title_full_unstemmed Detecção de Escherichia coli O157:H7 inoculada experimentalmente em amostras de leite cru por método convencional e PCR multiplex Detection of E. coli O157:H7 experimentally inoculated in raw milk samples by conventional method and multiplex PCR
title_short Detecção de Escherichia coli O157:H7 inoculada experimentalmente em amostras de leite cru por método convencional e PCR multiplex Detection of E. coli O157:H7 experimentally inoculated in raw milk samples by conventional method and multiplex PCR
title_sort deteccao de escherichia coli o157 h7 inoculada experimentalmente em amostras de leite cru por metodo convencional e pcr multiplex detection of e coli o157 h7 experimentally inoculated in raw milk samples by conventional method and multiplex pcr
topic PCR multiplex
E. coli O157:H7
antígeno O157
antígeno H7
genes para toxina tipo-shiga
PCR multiplex
E. coli O157:H7
O157 antigen
H7 antigen
shiga-like toxin genes
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0102-09352008000500029
work_keys_str_mv AT pmgarcia deteccaodeescherichiacolio157h7inoculadaexperimentalmenteemamostrasdeleitecrupormetodoconvencionalepcrmultiplexdetectionofecolio157h7experimentallyinoculatedinrawmilksamplesbyconventionalmethodandmultiplexpcr
AT efarcuri deteccaodeescherichiacolio157h7inoculadaexperimentalmenteemamostrasdeleitecrupormetodoconvencionalepcrmultiplexdetectionofecolio157h7experimentallyinoculatedinrawmilksamplesbyconventionalmethodandmultiplexpcr
AT mavpbrito deteccaodeescherichiacolio157h7inoculadaexperimentalmenteemamostrasdeleitecrupormetodoconvencionalepcrmultiplexdetectionofecolio157h7experimentallyinoculatedinrawmilksamplesbyconventionalmethodandmultiplexpcr
AT cclange deteccaodeescherichiacolio157h7inoculadaexperimentalmenteemamostrasdeleitecrupormetodoconvencionalepcrmultiplexdetectionofecolio157h7experimentallyinoculatedinrawmilksamplesbyconventionalmethodandmultiplexpcr
AT jrfbrito deteccaodeescherichiacolio157h7inoculadaexperimentalmenteemamostrasdeleitecrupormetodoconvencionalepcrmultiplexdetectionofecolio157h7experimentallyinoculatedinrawmilksamplesbyconventionalmethodandmultiplexpcr
AT mmopcerqueira deteccaodeescherichiacolio157h7inoculadaexperimentalmenteemamostrasdeleitecrupormetodoconvencionalepcrmultiplexdetectionofecolio157h7experimentallyinoculatedinrawmilksamplesbyconventionalmethodandmultiplexpcr