Accuracy of Evaluation of Fatty Liver with Third-Generation Unenhanced Dual-Energy CT and MRI: Prospective Comparison with MR Spectroscopy

Background and Objectives The purpose of this study is to evaluate and establish the accuracy of noninvasive methods, including third-generation dual-source dual-energy computed tomography (DECT) and proton density fat (PDF) fraction on magnetic resonance imaging (MRI) using three-dimensional multie...

Full description

Bibliographic Details
Main Authors: S. Rajesh, Venkatesh Kasi Arunachalam, Gopinath Periaswamy, Gobi Kalyan, Rupa Renganathan, Gowtham SM, Mathew Cherian
Format: Article
Language:English
Published: Thieme Medical and Scientific Publishers Pvt. Ltd. 2023-05-01
Series:Journal of Gastrointestinal and Abdominal Radiology
Subjects:
Online Access:http://www.thieme-connect.de/DOI/DOI?10.1055/s-0043-1763483
_version_ 1797804894693883904
author S. Rajesh
Venkatesh Kasi Arunachalam
Gopinath Periaswamy
Gobi Kalyan
Rupa Renganathan
Gowtham SM
Mathew Cherian
author_facet S. Rajesh
Venkatesh Kasi Arunachalam
Gopinath Periaswamy
Gobi Kalyan
Rupa Renganathan
Gowtham SM
Mathew Cherian
author_sort S. Rajesh
collection DOAJ
description Background and Objectives The purpose of this study is to evaluate and establish the accuracy of noninvasive methods, including third-generation dual-source dual-energy computed tomography (DECT) and proton density fat (PDF) fraction on magnetic resonance imaging (MRI) using three-dimensional multiecho multipoint chemical shift-encoded spoiled gradient echo (q-Dixon) sequence in the quantification of hepatic steatosis; with H1-MR spectroscopy (MRS) as the reference standard. Materials and Methods A total of 47 patients were included in this prospective study. We studied the accuracy of fatty liver detection using third-generation DECT using mixed set images (MSIs), virtual monochromatic images (VMIs), and MRI q-Dixon. The results were compared with H1-MRS. Data were analyzed using linear regression for each technique compared with MRS. Results Our study's correlation and linear regression analysis showed a good correlation between PDF values obtained by H1-MRS and MR q-Dixon methods (r = 0.821, r 2 = 0.674, p < 0.001). On MSI, H1-MRS showed a low correlation with average liver attenuation (r 2 = 0.379, p < 0.001) and a moderate correlation with liver attenuation index (r 2 = 0.508, p < 0.001) noted. There was a moderate correlation between H1-MRS and average liver attenuation and liver attenuation index on VMI at 80 to 120 keV with r 2 = 0.434, p < 0.001, and r 2 = 0.485, p < 0.001, respectively. Conclusion MRI q-Dixon is the method of choice for evaluating fat quantification in the absence of H1 MRS. Among DECT images, VMI is valuable in the evaluation of hepatic fat as compared with the mixed set of images.
first_indexed 2024-03-13T05:42:48Z
format Article
id doaj.art-8d1314f9c7fc4b80b8731333cdc3ce7c
institution Directory Open Access Journal
issn 2581-9178
language English
last_indexed 2024-03-13T05:42:48Z
publishDate 2023-05-01
publisher Thieme Medical and Scientific Publishers Pvt. Ltd.
record_format Article
series Journal of Gastrointestinal and Abdominal Radiology
spelling doaj.art-8d1314f9c7fc4b80b8731333cdc3ce7c2023-06-13T23:16:42ZengThieme Medical and Scientific Publishers Pvt. Ltd.Journal of Gastrointestinal and Abdominal Radiology2581-91782023-05-01060207908810.1055/s-0043-1763483Accuracy of Evaluation of Fatty Liver with Third-Generation Unenhanced Dual-Energy CT and MRI: Prospective Comparison with MR SpectroscopyS. Rajesh0Venkatesh Kasi Arunachalam1Gopinath Periaswamy2Gobi Kalyan3Rupa Renganathan4Gowtham SM5Mathew Cherian6Department of Radiology, Kovai Medical Center and Hospital, Coimbatore, Tamil Nadu, IndiaDepartment of Radiology, Kovai Medical Center and Hospital, Coimbatore, Tamil Nadu, IndiaDepartment of Radiology, Kovai Medical Center and Hospital, Coimbatore, Tamil Nadu, IndiaDepartment of Radiology, Kovai Medical Center and Hospital, Coimbatore, Tamil Nadu, IndiaDepartment of Radiology, Kovai Medical Center and Hospital, Coimbatore, Tamil Nadu, IndiaDepartment of Radiology, Kovai Medical Center and Hospital, Coimbatore, Tamil Nadu, IndiaDepartment of Radiology, Kovai Medical Center and Hospital, Coimbatore, Tamil Nadu, IndiaBackground and Objectives The purpose of this study is to evaluate and establish the accuracy of noninvasive methods, including third-generation dual-source dual-energy computed tomography (DECT) and proton density fat (PDF) fraction on magnetic resonance imaging (MRI) using three-dimensional multiecho multipoint chemical shift-encoded spoiled gradient echo (q-Dixon) sequence in the quantification of hepatic steatosis; with H1-MR spectroscopy (MRS) as the reference standard. Materials and Methods A total of 47 patients were included in this prospective study. We studied the accuracy of fatty liver detection using third-generation DECT using mixed set images (MSIs), virtual monochromatic images (VMIs), and MRI q-Dixon. The results were compared with H1-MRS. Data were analyzed using linear regression for each technique compared with MRS. Results Our study's correlation and linear regression analysis showed a good correlation between PDF values obtained by H1-MRS and MR q-Dixon methods (r = 0.821, r 2 = 0.674, p < 0.001). On MSI, H1-MRS showed a low correlation with average liver attenuation (r 2 = 0.379, p < 0.001) and a moderate correlation with liver attenuation index (r 2 = 0.508, p < 0.001) noted. There was a moderate correlation between H1-MRS and average liver attenuation and liver attenuation index on VMI at 80 to 120 keV with r 2 = 0.434, p < 0.001, and r 2 = 0.485, p < 0.001, respectively. Conclusion MRI q-Dixon is the method of choice for evaluating fat quantification in the absence of H1 MRS. Among DECT images, VMI is valuable in the evaluation of hepatic fat as compared with the mixed set of images.http://www.thieme-connect.de/DOI/DOI?10.1055/s-0043-1763483virtual monochromaticthird generationdual-sourcedual-energypdffq-dixonfat quantificationnoncontrast
spellingShingle S. Rajesh
Venkatesh Kasi Arunachalam
Gopinath Periaswamy
Gobi Kalyan
Rupa Renganathan
Gowtham SM
Mathew Cherian
Accuracy of Evaluation of Fatty Liver with Third-Generation Unenhanced Dual-Energy CT and MRI: Prospective Comparison with MR Spectroscopy
Journal of Gastrointestinal and Abdominal Radiology
virtual monochromatic
third generation
dual-source
dual-energy
pdff
q-dixon
fat quantification
noncontrast
title Accuracy of Evaluation of Fatty Liver with Third-Generation Unenhanced Dual-Energy CT and MRI: Prospective Comparison with MR Spectroscopy
title_full Accuracy of Evaluation of Fatty Liver with Third-Generation Unenhanced Dual-Energy CT and MRI: Prospective Comparison with MR Spectroscopy
title_fullStr Accuracy of Evaluation of Fatty Liver with Third-Generation Unenhanced Dual-Energy CT and MRI: Prospective Comparison with MR Spectroscopy
title_full_unstemmed Accuracy of Evaluation of Fatty Liver with Third-Generation Unenhanced Dual-Energy CT and MRI: Prospective Comparison with MR Spectroscopy
title_short Accuracy of Evaluation of Fatty Liver with Third-Generation Unenhanced Dual-Energy CT and MRI: Prospective Comparison with MR Spectroscopy
title_sort accuracy of evaluation of fatty liver with third generation unenhanced dual energy ct and mri prospective comparison with mr spectroscopy
topic virtual monochromatic
third generation
dual-source
dual-energy
pdff
q-dixon
fat quantification
noncontrast
url http://www.thieme-connect.de/DOI/DOI?10.1055/s-0043-1763483
work_keys_str_mv AT srajesh accuracyofevaluationoffattyliverwiththirdgenerationunenhanceddualenergyctandmriprospectivecomparisonwithmrspectroscopy
AT venkateshkasiarunachalam accuracyofevaluationoffattyliverwiththirdgenerationunenhanceddualenergyctandmriprospectivecomparisonwithmrspectroscopy
AT gopinathperiaswamy accuracyofevaluationoffattyliverwiththirdgenerationunenhanceddualenergyctandmriprospectivecomparisonwithmrspectroscopy
AT gobikalyan accuracyofevaluationoffattyliverwiththirdgenerationunenhanceddualenergyctandmriprospectivecomparisonwithmrspectroscopy
AT ruparenganathan accuracyofevaluationoffattyliverwiththirdgenerationunenhanceddualenergyctandmriprospectivecomparisonwithmrspectroscopy
AT gowthamsm accuracyofevaluationoffattyliverwiththirdgenerationunenhanceddualenergyctandmriprospectivecomparisonwithmrspectroscopy
AT mathewcherian accuracyofevaluationoffattyliverwiththirdgenerationunenhanceddualenergyctandmriprospectivecomparisonwithmrspectroscopy