In this research the behavior of reactive powder concrete short (RPC) columns with and without reinforcement was reported. Eight specimens of RPC short columns with reinforcing steel and without reinforcing steel are examined and compared with eight specimens of high strength reinforced concrete (H...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | Arabic |
Published: |
Mustansiriyah University/College of Engineering
2013-06-01
|
Series: | Journal of Engineering and Sustainable Development |
Subjects: | |
Online Access: | https://jeasd.uomustansiriyah.edu.iq/index.php/jeasd/article/view/1124 |
_version_ | 1817975838432296960 |
---|---|
author | Maha M.S. Ridha Taghreed K. Mohammad Ali Zeena W. Abbawi |
author_facet | Maha M.S. Ridha Taghreed K. Mohammad Ali Zeena W. Abbawi |
author_sort | Maha M.S. Ridha |
collection | DOAJ |
description |
In this research the behavior of reactive powder concrete short (RPC) columns with and without reinforcement was reported. Eight specimens of RPC short columns with reinforcing steel and without reinforcing steel are examined and compared with eight specimens of high strength reinforced concrete (HSC) short columns. The columns samples are divided into two groups. The dimensions of the first group are (100 *100* 400) mm and the dimensions of the second group are (70*70*400) mm. The lateral reinforcing steel, which are used in the reinforced concrete short columns, that are tied or spirally reinforced. Experimental data for strength, lateral and axial deformation, ductility and the failure mode were obtained for each test. The failure load of RPC short columns without reinforcing steel is more than the failure load of RPC short columns with reinforcing steel by about 1.222 time for the two groups. The failure mode of RPC short columns without reinforcing steel is shear failure, while the failure mode of RPC short columns with reinforcing steel is rupture of some ties. The carrying capacity of RPC columns with and without reinforcing steel as compared to corresponding HSC columns is about 3.6 and 4.4 times respectively
|
first_indexed | 2024-04-13T21:55:36Z |
format | Article |
id | doaj.art-8de319121df24d9999230215c53d8e0e |
institution | Directory Open Access Journal |
issn | 2520-0917 2520-0925 |
language | Arabic |
last_indexed | 2024-04-13T21:55:36Z |
publishDate | 2013-06-01 |
publisher | Mustansiriyah University/College of Engineering |
record_format | Article |
series | Journal of Engineering and Sustainable Development |
spelling | doaj.art-8de319121df24d9999230215c53d8e0e2022-12-22T02:28:16ZaraMustansiriyah University/College of EngineeringJournal of Engineering and Sustainable Development2520-09172520-09252013-06-01172Behavior of Axially Loaded Reactive Powder Concrete ColumnsMaha M.S. Ridha0Taghreed K. Mohammad Ali1Zeena W. Abbawi 2University Technology, Baghdad, IraqUniversity of Koya, Kurdistan, IraqUniversity Technology, Baghdad, Iraq In this research the behavior of reactive powder concrete short (RPC) columns with and without reinforcement was reported. Eight specimens of RPC short columns with reinforcing steel and without reinforcing steel are examined and compared with eight specimens of high strength reinforced concrete (HSC) short columns. The columns samples are divided into two groups. The dimensions of the first group are (100 *100* 400) mm and the dimensions of the second group are (70*70*400) mm. The lateral reinforcing steel, which are used in the reinforced concrete short columns, that are tied or spirally reinforced. Experimental data for strength, lateral and axial deformation, ductility and the failure mode were obtained for each test. The failure load of RPC short columns without reinforcing steel is more than the failure load of RPC short columns with reinforcing steel by about 1.222 time for the two groups. The failure mode of RPC short columns without reinforcing steel is shear failure, while the failure mode of RPC short columns with reinforcing steel is rupture of some ties. The carrying capacity of RPC columns with and without reinforcing steel as compared to corresponding HSC columns is about 3.6 and 4.4 times respectively https://jeasd.uomustansiriyah.edu.iq/index.php/jeasd/article/view/11240 |
spellingShingle | Maha M.S. Ridha Taghreed K. Mohammad Ali Zeena W. Abbawi Behavior of Axially Loaded Reactive Powder Concrete Columns Journal of Engineering and Sustainable Development 0 |
title | Behavior of Axially Loaded Reactive Powder Concrete Columns |
title_full | Behavior of Axially Loaded Reactive Powder Concrete Columns |
title_fullStr | Behavior of Axially Loaded Reactive Powder Concrete Columns |
title_full_unstemmed | Behavior of Axially Loaded Reactive Powder Concrete Columns |
title_short | Behavior of Axially Loaded Reactive Powder Concrete Columns |
title_sort | behavior of axially loaded reactive powder concrete columns |
topic | 0 |
url | https://jeasd.uomustansiriyah.edu.iq/index.php/jeasd/article/view/1124 |
work_keys_str_mv | AT mahamsridha behaviorofaxiallyloadedreactivepowderconcretecolumns AT taghreedkmohammadali behaviorofaxiallyloadedreactivepowderconcretecolumns AT zeenawabbawi behaviorofaxiallyloadedreactivepowderconcretecolumns |