Behavior of Axially Loaded Reactive Powder Concrete Columns

In this research the behavior of reactive powder concrete short (RPC) columns with and without reinforcement was reported. Eight specimens of RPC short columns with reinforcing steel and without reinforcing steel are examined and compared with eight specimens of high strength reinforced concrete (H...

Full description

Bibliographic Details
Main Authors: Maha M.S. Ridha, Taghreed K. Mohammad Ali, Zeena W. Abbawi
Format: Article
Language:Arabic
Published: Mustansiriyah University/College of Engineering 2013-06-01
Series:Journal of Engineering and Sustainable Development
Subjects:
0
Online Access:https://jeasd.uomustansiriyah.edu.iq/index.php/jeasd/article/view/1124
_version_ 1817975838432296960
author Maha M.S. Ridha
Taghreed K. Mohammad Ali
Zeena W. Abbawi
author_facet Maha M.S. Ridha
Taghreed K. Mohammad Ali
Zeena W. Abbawi
author_sort Maha M.S. Ridha
collection DOAJ
description In this research the behavior of reactive powder concrete short (RPC) columns with and without reinforcement was reported. Eight specimens of RPC short columns with reinforcing steel and without reinforcing steel are examined and compared with eight specimens of high strength reinforced concrete (HSC) short columns. The columns samples are divided into two groups. The dimensions of the first group are (100 *100* 400) mm and the dimensions of the second group are (70*70*400) mm. The lateral reinforcing steel, which are used in the reinforced concrete short columns, that are tied or spirally reinforced. Experimental data for strength, lateral and axial deformation, ductility and the failure mode were obtained for each test. The failure load of RPC short columns without reinforcing steel is more than the failure load of RPC short columns with reinforcing steel by about 1.222 time for the two groups. The failure mode of RPC short columns without reinforcing steel is shear failure, while the failure mode of RPC short columns with reinforcing steel is rupture of some ties. The carrying capacity of RPC columns with and without reinforcing steel as compared to corresponding HSC columns is about 3.6 and 4.4 times respectively
first_indexed 2024-04-13T21:55:36Z
format Article
id doaj.art-8de319121df24d9999230215c53d8e0e
institution Directory Open Access Journal
issn 2520-0917
2520-0925
language Arabic
last_indexed 2024-04-13T21:55:36Z
publishDate 2013-06-01
publisher Mustansiriyah University/College of Engineering
record_format Article
series Journal of Engineering and Sustainable Development
spelling doaj.art-8de319121df24d9999230215c53d8e0e2022-12-22T02:28:16ZaraMustansiriyah University/College of EngineeringJournal of Engineering and Sustainable Development2520-09172520-09252013-06-01172Behavior of Axially Loaded Reactive Powder Concrete ColumnsMaha M.S. Ridha0Taghreed K. Mohammad Ali1Zeena W. Abbawi 2University Technology, Baghdad, IraqUniversity of Koya, Kurdistan, IraqUniversity Technology, Baghdad, Iraq In this research the behavior of reactive powder concrete short (RPC) columns with and without reinforcement was reported. Eight specimens of RPC short columns with reinforcing steel and without reinforcing steel are examined and compared with eight specimens of high strength reinforced concrete (HSC) short columns. The columns samples are divided into two groups. The dimensions of the first group are (100 *100* 400) mm and the dimensions of the second group are (70*70*400) mm. The lateral reinforcing steel, which are used in the reinforced concrete short columns, that are tied or spirally reinforced. Experimental data for strength, lateral and axial deformation, ductility and the failure mode were obtained for each test. The failure load of RPC short columns without reinforcing steel is more than the failure load of RPC short columns with reinforcing steel by about 1.222 time for the two groups. The failure mode of RPC short columns without reinforcing steel is shear failure, while the failure mode of RPC short columns with reinforcing steel is rupture of some ties. The carrying capacity of RPC columns with and without reinforcing steel as compared to corresponding HSC columns is about 3.6 and 4.4 times respectively https://jeasd.uomustansiriyah.edu.iq/index.php/jeasd/article/view/11240
spellingShingle Maha M.S. Ridha
Taghreed K. Mohammad Ali
Zeena W. Abbawi
Behavior of Axially Loaded Reactive Powder Concrete Columns
Journal of Engineering and Sustainable Development
0
title Behavior of Axially Loaded Reactive Powder Concrete Columns
title_full Behavior of Axially Loaded Reactive Powder Concrete Columns
title_fullStr Behavior of Axially Loaded Reactive Powder Concrete Columns
title_full_unstemmed Behavior of Axially Loaded Reactive Powder Concrete Columns
title_short Behavior of Axially Loaded Reactive Powder Concrete Columns
title_sort behavior of axially loaded reactive powder concrete columns
topic 0
url https://jeasd.uomustansiriyah.edu.iq/index.php/jeasd/article/view/1124
work_keys_str_mv AT mahamsridha behaviorofaxiallyloadedreactivepowderconcretecolumns
AT taghreedkmohammadali behaviorofaxiallyloadedreactivepowderconcretecolumns
AT zeenawabbawi behaviorofaxiallyloadedreactivepowderconcretecolumns