Comparison of Shear Bond Strength, Adhesive Remnant and Precision Fit between Conventional Lingual Retainers and Customised CAD/CAM Fabricated Lingual Retainers: An In-vitro Study

Introduction: Fixed lingual bonded retainers offer the comfort of aesthetics and reduced tissue irritation after orthodontic treatment but are wrought with frequent bond failures. Numerous techniques have been used to adapt the retainer to the lingual surface of the lower anterior teeth, but researc...

Full description

Bibliographic Details
Main Authors: B Mohamed Sohail, Poornima R Jnaneshwar, Dilip Srinivasan, Ravi Kannan
Format: Article
Language:English
Published: JCDR Research and Publications Private Limited 2024-04-01
Series:Journal of Clinical and Diagnostic Research
Subjects:
Online Access:https://www.jcdr.net/articles/PDF/19321/66699_CE[Ra1]_F(IS)_QC(AnK_RDW_IS)_PF1(RI_DK_OM)_PFA(RI_KM)_PN(KM).pdf
_version_ 1797209839269576704
author B Mohamed Sohail
Poornima R Jnaneshwar
Dilip Srinivasan
Ravi Kannan
author_facet B Mohamed Sohail
Poornima R Jnaneshwar
Dilip Srinivasan
Ravi Kannan
author_sort B Mohamed Sohail
collection DOAJ
description Introduction: Fixed lingual bonded retainers offer the comfort of aesthetics and reduced tissue irritation after orthodontic treatment but are wrought with frequent bond failures. Numerous techniques have been used to adapt the retainer to the lingual surface of the lower anterior teeth, but research on customised lower lingual retainers is scarce. Aim: To evaluate and compare the Shear Bond Strength (SBS), Adhesive Remnant Index scores (ARI), and precision fit of a novel Computer-aided Designing-Computer-aided Machining/Manufacturing (CAD-CAM) fabricated retainer and conventional retainers. Materials and Methods: This invitro study was conducted at the Department of Orthodontics, and Dentofacial Orthopaedics, SRM Dental College, Ramapuram, Chennai-89 from June 2022 to February 2023. It included a total of 360 human mandibular anterior teeth were collected and embedded in acrylic blocks in groups of six to simulate the mandibular anterior arch form. A total of 60 retainers made of braided Stainless Steel (SS) wires, co-axial wires, customised through CAD/CAM technology were evaluated. The retainers were bonded to the lingual aspect of the teeth using composite resin. A universal testing machine was used for testing SBS. Precision fit was observed using Exocad software. Statistical analysis included one-way Analysis of Variance (ANOVA) for SBS, Kruskal-Wallis for ARI score, and Mann-Whitney U test for precision fit. Results: The CAD-CAM retainers had a more precise fit when compared to conventional retainers (p=0.009). SBS was highest for CAD-CAM fabricated retainer and lowest in the co-axial retainer, and this finding was statistically significant (p<0.001). The CAD-CAM retainer had the highest mean rank in ARI scores (33.90) when compared to braided SS and co-axial wire. Conclusion: The CAD-CAM fabricated retainers would be more effective clinically, as higher bond strength due to precise fit would reduce the failure rate, thus preventing relapse and minimising chairside time.
first_indexed 2024-04-24T10:01:04Z
format Article
id doaj.art-8e3172dc353b43319c5adf3f4aa43a68
institution Directory Open Access Journal
issn 2249-782X
0973-709X
language English
last_indexed 2024-04-24T10:01:04Z
publishDate 2024-04-01
publisher JCDR Research and Publications Private Limited
record_format Article
series Journal of Clinical and Diagnostic Research
spelling doaj.art-8e3172dc353b43319c5adf3f4aa43a682024-04-13T11:44:30ZengJCDR Research and Publications Private LimitedJournal of Clinical and Diagnostic Research2249-782X0973-709X2024-04-011804010510.7860/JCDR/2024/66699.19321Comparison of Shear Bond Strength, Adhesive Remnant and Precision Fit between Conventional Lingual Retainers and Customised CAD/CAM Fabricated Lingual Retainers: An In-vitro StudyB Mohamed Sohail0Poornima R Jnaneshwar1Dilip Srinivasan2Ravi Kannan3Postgraduate Student, Department of Orthodontics and Dentofacial Orthopaedics, SRM Dental College, Ramapuram Chennai, Tamil Nadu, India.Professor, Department of Orthodontics and Dentofacial Orthopaedics, SRM Dental College, Ramapuram, Chennai, Tamil Nadu, India.Professor, Department of Orthodontics and Dentofacial Orthopaedics, SRM Dental College, Ramapuram, Chennai, Tamil Nadu, India.Dean and Head, Department of Orthodontics and Dentofacial Orthopaedics, SRM Dental College, Ramapuram, Chennai, Tamil Nadu, India.Introduction: Fixed lingual bonded retainers offer the comfort of aesthetics and reduced tissue irritation after orthodontic treatment but are wrought with frequent bond failures. Numerous techniques have been used to adapt the retainer to the lingual surface of the lower anterior teeth, but research on customised lower lingual retainers is scarce. Aim: To evaluate and compare the Shear Bond Strength (SBS), Adhesive Remnant Index scores (ARI), and precision fit of a novel Computer-aided Designing-Computer-aided Machining/Manufacturing (CAD-CAM) fabricated retainer and conventional retainers. Materials and Methods: This invitro study was conducted at the Department of Orthodontics, and Dentofacial Orthopaedics, SRM Dental College, Ramapuram, Chennai-89 from June 2022 to February 2023. It included a total of 360 human mandibular anterior teeth were collected and embedded in acrylic blocks in groups of six to simulate the mandibular anterior arch form. A total of 60 retainers made of braided Stainless Steel (SS) wires, co-axial wires, customised through CAD/CAM technology were evaluated. The retainers were bonded to the lingual aspect of the teeth using composite resin. A universal testing machine was used for testing SBS. Precision fit was observed using Exocad software. Statistical analysis included one-way Analysis of Variance (ANOVA) for SBS, Kruskal-Wallis for ARI score, and Mann-Whitney U test for precision fit. Results: The CAD-CAM retainers had a more precise fit when compared to conventional retainers (p=0.009). SBS was highest for CAD-CAM fabricated retainer and lowest in the co-axial retainer, and this finding was statistically significant (p<0.001). The CAD-CAM retainer had the highest mean rank in ARI scores (33.90) when compared to braided SS and co-axial wire. Conclusion: The CAD-CAM fabricated retainers would be more effective clinically, as higher bond strength due to precise fit would reduce the failure rate, thus preventing relapse and minimising chairside time.https://www.jcdr.net/articles/PDF/19321/66699_CE[Ra1]_F(IS)_QC(AnK_RDW_IS)_PF1(RI_DK_OM)_PFA(RI_KM)_PN(KM).pdfbond failure of lingual retainerscomputer-aided designing-computer-aided machining/manufacturingfixed lingual retainerorthodontic retention
spellingShingle B Mohamed Sohail
Poornima R Jnaneshwar
Dilip Srinivasan
Ravi Kannan
Comparison of Shear Bond Strength, Adhesive Remnant and Precision Fit between Conventional Lingual Retainers and Customised CAD/CAM Fabricated Lingual Retainers: An In-vitro Study
Journal of Clinical and Diagnostic Research
bond failure of lingual retainers
computer-aided designing-computer-aided machining/manufacturing
fixed lingual retainer
orthodontic retention
title Comparison of Shear Bond Strength, Adhesive Remnant and Precision Fit between Conventional Lingual Retainers and Customised CAD/CAM Fabricated Lingual Retainers: An In-vitro Study
title_full Comparison of Shear Bond Strength, Adhesive Remnant and Precision Fit between Conventional Lingual Retainers and Customised CAD/CAM Fabricated Lingual Retainers: An In-vitro Study
title_fullStr Comparison of Shear Bond Strength, Adhesive Remnant and Precision Fit between Conventional Lingual Retainers and Customised CAD/CAM Fabricated Lingual Retainers: An In-vitro Study
title_full_unstemmed Comparison of Shear Bond Strength, Adhesive Remnant and Precision Fit between Conventional Lingual Retainers and Customised CAD/CAM Fabricated Lingual Retainers: An In-vitro Study
title_short Comparison of Shear Bond Strength, Adhesive Remnant and Precision Fit between Conventional Lingual Retainers and Customised CAD/CAM Fabricated Lingual Retainers: An In-vitro Study
title_sort comparison of shear bond strength adhesive remnant and precision fit between conventional lingual retainers and customised cad cam fabricated lingual retainers an in vitro study
topic bond failure of lingual retainers
computer-aided designing-computer-aided machining/manufacturing
fixed lingual retainer
orthodontic retention
url https://www.jcdr.net/articles/PDF/19321/66699_CE[Ra1]_F(IS)_QC(AnK_RDW_IS)_PF1(RI_DK_OM)_PFA(RI_KM)_PN(KM).pdf
work_keys_str_mv AT bmohamedsohail comparisonofshearbondstrengthadhesiveremnantandprecisionfitbetweenconventionallingualretainersandcustomisedcadcamfabricatedlingualretainersaninvitrostudy
AT poornimarjnaneshwar comparisonofshearbondstrengthadhesiveremnantandprecisionfitbetweenconventionallingualretainersandcustomisedcadcamfabricatedlingualretainersaninvitrostudy
AT dilipsrinivasan comparisonofshearbondstrengthadhesiveremnantandprecisionfitbetweenconventionallingualretainersandcustomisedcadcamfabricatedlingualretainersaninvitrostudy
AT ravikannan comparisonofshearbondstrengthadhesiveremnantandprecisionfitbetweenconventionallingualretainersandcustomisedcadcamfabricatedlingualretainersaninvitrostudy