Numerical Analysis of Heat Transfer Enhancement of Solar Air Heater using Discrete Triangle Wave Corrugations

Enhancement of heat transfer in solar air heater systems using corrugations has the dual benefit of enhanced heat transfer area and enhanced flow turbulence. This work presents two-dimensional computational fluid dynamics (CFD) analysis to evaluate the effect of discrete triangle wave corrugations o...

Full description

Bibliographic Details
Main Authors: Vansh Ratna Sharma, Sai Sankalp S, Dolfred Vijay Fernandes, Manjunath M S
Format: Article
Language:English
Published: Taylor & Francis Group 2022-12-01
Series:Cogent Engineering
Subjects:
Online Access:https://www.tandfonline.com/doi/10.1080/23311916.2022.2051312
_version_ 1797760016623599616
author Vansh Ratna Sharma
Sai Sankalp S
Dolfred Vijay Fernandes
Manjunath M S
author_facet Vansh Ratna Sharma
Sai Sankalp S
Dolfred Vijay Fernandes
Manjunath M S
author_sort Vansh Ratna Sharma
collection DOAJ
description Enhancement of heat transfer in solar air heater systems using corrugations has the dual benefit of enhanced heat transfer area and enhanced flow turbulence. This work presents two-dimensional computational fluid dynamics (CFD) analysis to evaluate the effect of discrete triangle wave corrugations on the absorber plate for different flow Reynolds numbers of 6000–24000. The geometric parameters of corrugation such as the non-dimensional amplitude (A = 0.025, 0.05 and 0.1) and non-dimensional wavelength (WL = 0.113, 0.226 and 0.453) are varied to establish the thermo-hydraulic performance. The CFD results reveal that the presence of discrete triangle wave corrugations significantly affect the flow structure near the absorber surface and exhibit enhanced fluid turbulence levels. The highest increase in the Nusselt number is found to be about 2.082 times higher than that of the smooth duct for A = 0.1 and WL = 0.453 at Re = 6000. The maximum rise in friction factor is about 2.568 times that of the smooth duct at Re = 6000 for the configuration of WL = 0.113 and A = 0.1. The configuration having A = 0.1 and WL = 0.453 can be particularly useful for lower flow rate requirements and exhibits the highest thermal enhancement factor (TEF) of about 1.612 at Re = 6000 among all the configurations considered in the present study. However, the configuration having A = 0.05 and WL = 0.453 provides a relatively steady TEF performance for a wider range of flow rates with a maximum TEF of 1.473 at Re = 12,000.
first_indexed 2024-03-12T18:52:42Z
format Article
id doaj.art-8e422aac047c4bc6b39347a5e88eaad9
institution Directory Open Access Journal
issn 2331-1916
language English
last_indexed 2024-03-12T18:52:42Z
publishDate 2022-12-01
publisher Taylor & Francis Group
record_format Article
series Cogent Engineering
spelling doaj.art-8e422aac047c4bc6b39347a5e88eaad92023-08-02T07:04:07ZengTaylor & Francis GroupCogent Engineering2331-19162022-12-019110.1080/23311916.2022.2051312Numerical Analysis of Heat Transfer Enhancement of Solar Air Heater using Discrete Triangle Wave CorrugationsVansh Ratna Sharma0Sai Sankalp S1Dolfred Vijay Fernandes2Manjunath M S3Department of Mechanical and Industrial Engineering, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, India-576104Department of Aeronautical and Automobile Engineering, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, India-576104Department of Mechanical and Industrial Engineering, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, India-576104Department of Mechanical and Industrial Engineering, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, India-576104Enhancement of heat transfer in solar air heater systems using corrugations has the dual benefit of enhanced heat transfer area and enhanced flow turbulence. This work presents two-dimensional computational fluid dynamics (CFD) analysis to evaluate the effect of discrete triangle wave corrugations on the absorber plate for different flow Reynolds numbers of 6000–24000. The geometric parameters of corrugation such as the non-dimensional amplitude (A = 0.025, 0.05 and 0.1) and non-dimensional wavelength (WL = 0.113, 0.226 and 0.453) are varied to establish the thermo-hydraulic performance. The CFD results reveal that the presence of discrete triangle wave corrugations significantly affect the flow structure near the absorber surface and exhibit enhanced fluid turbulence levels. The highest increase in the Nusselt number is found to be about 2.082 times higher than that of the smooth duct for A = 0.1 and WL = 0.453 at Re = 6000. The maximum rise in friction factor is about 2.568 times that of the smooth duct at Re = 6000 for the configuration of WL = 0.113 and A = 0.1. The configuration having A = 0.1 and WL = 0.453 can be particularly useful for lower flow rate requirements and exhibits the highest thermal enhancement factor (TEF) of about 1.612 at Re = 6000 among all the configurations considered in the present study. However, the configuration having A = 0.05 and WL = 0.453 provides a relatively steady TEF performance for a wider range of flow rates with a maximum TEF of 1.473 at Re = 12,000.https://www.tandfonline.com/doi/10.1080/23311916.2022.2051312Triangle wave corrugationssolar energyTEFturbulence
spellingShingle Vansh Ratna Sharma
Sai Sankalp S
Dolfred Vijay Fernandes
Manjunath M S
Numerical Analysis of Heat Transfer Enhancement of Solar Air Heater using Discrete Triangle Wave Corrugations
Cogent Engineering
Triangle wave corrugations
solar energy
TEF
turbulence
title Numerical Analysis of Heat Transfer Enhancement of Solar Air Heater using Discrete Triangle Wave Corrugations
title_full Numerical Analysis of Heat Transfer Enhancement of Solar Air Heater using Discrete Triangle Wave Corrugations
title_fullStr Numerical Analysis of Heat Transfer Enhancement of Solar Air Heater using Discrete Triangle Wave Corrugations
title_full_unstemmed Numerical Analysis of Heat Transfer Enhancement of Solar Air Heater using Discrete Triangle Wave Corrugations
title_short Numerical Analysis of Heat Transfer Enhancement of Solar Air Heater using Discrete Triangle Wave Corrugations
title_sort numerical analysis of heat transfer enhancement of solar air heater using discrete triangle wave corrugations
topic Triangle wave corrugations
solar energy
TEF
turbulence
url https://www.tandfonline.com/doi/10.1080/23311916.2022.2051312
work_keys_str_mv AT vanshratnasharma numericalanalysisofheattransferenhancementofsolarairheaterusingdiscretetrianglewavecorrugations
AT saisankalps numericalanalysisofheattransferenhancementofsolarairheaterusingdiscretetrianglewavecorrugations
AT dolfredvijayfernandes numericalanalysisofheattransferenhancementofsolarairheaterusingdiscretetrianglewavecorrugations
AT manjunathms numericalanalysisofheattransferenhancementofsolarairheaterusingdiscretetrianglewavecorrugations