Cooperative Control with Ultrasound Guidance for Radiation Therapy

Radiation therapy typically begins with the acquisition of a CT scan of the patient for planning, followed by multiple days where radiation is delivered according to the plan. This requires that the patient be reproducibly positioned (set up) on the radiation therapy device (linear accelerator) such...

Full description

Bibliographic Details
Main Authors: Hasan Tutkun Sen, Alexis Cheng, Kai Ding, Emad Boctor, John Wong, Iulian Iordachita, Peter Kazanzides
Format: Article
Language:English
Published: Frontiers Media S.A. 2016-08-01
Series:Frontiers in Robotics and AI
Subjects:
Online Access:http://journal.frontiersin.org/Journal/10.3389/frobt.2016.00049/full
_version_ 1818476318061232128
author Hasan Tutkun Sen
Alexis Cheng
Kai Ding
Emad Boctor
John Wong
Iulian Iordachita
Peter Kazanzides
author_facet Hasan Tutkun Sen
Alexis Cheng
Kai Ding
Emad Boctor
John Wong
Iulian Iordachita
Peter Kazanzides
author_sort Hasan Tutkun Sen
collection DOAJ
description Radiation therapy typically begins with the acquisition of a CT scan of the patient for planning, followed by multiple days where radiation is delivered according to the plan. This requires that the patient be reproducibly positioned (set up) on the radiation therapy device (linear accelerator) such that the radiation beams pass through the target. Modern linear accelerators provide cone-beam computed tomography (CBCT) imaging, but this does not provide sufficient contrast to discriminate many abdominal soft-tissue targets and therefore patient setup is often done by aligning bony anatomy or implanted fiducials. Ultrasound (US) can be used to both assist with patient setup and to provide real-time monitoring of soft-tissue targets. One challenge, however, is that the ultrasound probe contact pressure can deform the target area and cause discrepancies with the treatment plan. Another challenge is that radiation therapists typically do not have ultrasound experience and therefore cannot easily find the target in the US image. We propose cooperative control strategies to address both challenges. First, we use cooperative control with virtual fixtures (VFs) to enable acquisition of a planning CT that includes the soft-tissue deformation. Then, for the patient setup during the treatment sessions, we propose to use real-time US image feedback to dynamically update the VFs; this co-manipulation strategy provides haptic cues that guide the therapist to correctly place the US probe. A phantom study is performed to demonstrate that the co-manipulation strategy enables inexperienced operators to quickly and accurately place the probe on a phantom to reproduce a desired reference image. This is a necessary step for patient setup and, by reproducing the reference image, creates soft-tissue deformations that are consistent with the treatment plan, thereby enabling real-time monitoring during treatment delivery.
first_indexed 2024-12-10T09:24:04Z
format Article
id doaj.art-8e494dea1ad743a0bf13767a1382c77c
institution Directory Open Access Journal
issn 2296-9144
language English
last_indexed 2024-12-10T09:24:04Z
publishDate 2016-08-01
publisher Frontiers Media S.A.
record_format Article
series Frontiers in Robotics and AI
spelling doaj.art-8e494dea1ad743a0bf13767a1382c77c2022-12-22T01:54:36ZengFrontiers Media S.A.Frontiers in Robotics and AI2296-91442016-08-01310.3389/frobt.2016.00049204220Cooperative Control with Ultrasound Guidance for Radiation TherapyHasan Tutkun Sen0Alexis Cheng1Kai Ding2Emad Boctor3John Wong4Iulian Iordachita5Peter Kazanzides6Johns Hopkins UniversityJohns Hopkins UniversityJohns Hopkins UniversityJohns Hopkins UniversityJohns Hopkins UniversityJohns Hopkins UniversityJohns Hopkins UniversityRadiation therapy typically begins with the acquisition of a CT scan of the patient for planning, followed by multiple days where radiation is delivered according to the plan. This requires that the patient be reproducibly positioned (set up) on the radiation therapy device (linear accelerator) such that the radiation beams pass through the target. Modern linear accelerators provide cone-beam computed tomography (CBCT) imaging, but this does not provide sufficient contrast to discriminate many abdominal soft-tissue targets and therefore patient setup is often done by aligning bony anatomy or implanted fiducials. Ultrasound (US) can be used to both assist with patient setup and to provide real-time monitoring of soft-tissue targets. One challenge, however, is that the ultrasound probe contact pressure can deform the target area and cause discrepancies with the treatment plan. Another challenge is that radiation therapists typically do not have ultrasound experience and therefore cannot easily find the target in the US image. We propose cooperative control strategies to address both challenges. First, we use cooperative control with virtual fixtures (VFs) to enable acquisition of a planning CT that includes the soft-tissue deformation. Then, for the patient setup during the treatment sessions, we propose to use real-time US image feedback to dynamically update the VFs; this co-manipulation strategy provides haptic cues that guide the therapist to correctly place the US probe. A phantom study is performed to demonstrate that the co-manipulation strategy enables inexperienced operators to quickly and accurately place the probe on a phantom to reproduce a desired reference image. This is a necessary step for patient setup and, by reproducing the reference image, creates soft-tissue deformations that are consistent with the treatment plan, thereby enabling real-time monitoring during treatment delivery.http://journal.frontiersin.org/Journal/10.3389/frobt.2016.00049/fullCooperative ControlVirtual fixturesHuman-in-the-loop Image ServoingRobot Assisted RadiotherapyUltrasound Guided Radiotherapy
spellingShingle Hasan Tutkun Sen
Alexis Cheng
Kai Ding
Emad Boctor
John Wong
Iulian Iordachita
Peter Kazanzides
Cooperative Control with Ultrasound Guidance for Radiation Therapy
Frontiers in Robotics and AI
Cooperative Control
Virtual fixtures
Human-in-the-loop Image Servoing
Robot Assisted Radiotherapy
Ultrasound Guided Radiotherapy
title Cooperative Control with Ultrasound Guidance for Radiation Therapy
title_full Cooperative Control with Ultrasound Guidance for Radiation Therapy
title_fullStr Cooperative Control with Ultrasound Guidance for Radiation Therapy
title_full_unstemmed Cooperative Control with Ultrasound Guidance for Radiation Therapy
title_short Cooperative Control with Ultrasound Guidance for Radiation Therapy
title_sort cooperative control with ultrasound guidance for radiation therapy
topic Cooperative Control
Virtual fixtures
Human-in-the-loop Image Servoing
Robot Assisted Radiotherapy
Ultrasound Guided Radiotherapy
url http://journal.frontiersin.org/Journal/10.3389/frobt.2016.00049/full
work_keys_str_mv AT hasantutkunsen cooperativecontrolwithultrasoundguidanceforradiationtherapy
AT alexischeng cooperativecontrolwithultrasoundguidanceforradiationtherapy
AT kaiding cooperativecontrolwithultrasoundguidanceforradiationtherapy
AT emadboctor cooperativecontrolwithultrasoundguidanceforradiationtherapy
AT johnwong cooperativecontrolwithultrasoundguidanceforradiationtherapy
AT iulianiordachita cooperativecontrolwithultrasoundguidanceforradiationtherapy
AT peterkazanzides cooperativecontrolwithultrasoundguidanceforradiationtherapy