Application of Distributed Measuring System of Ventilator Performance in Coal Mine and Its Analysis

A distributed measuring system of ventilator performance was used to measure performance of two main ventilators of west airshaft in Dongtan Coal Mine, and curves of blastvolume-air pressure, blastvolume-power and blastvolume-efficiency were drawn according to the measured data. Ventilation abilitie...

Full description

Bibliographic Details
Main Authors: JIANG Shu-guang, JIN Fu, WU Zheng-yan, LI Hui-ming, MIAO Shuang-tao
Format: Article
Language:zho
Published: Editorial Department of Industry and Mine Automation 2011-02-01
Series:Gong-kuang zidonghua
Subjects:
Online Access:http://www.gkzdh.cn/article/id/2457
_version_ 1797868438636462080
author JIANG Shu-guang
JIN Fu
WU Zheng-yan
LI Hui-ming
MIAO Shuang-tao
author_facet JIANG Shu-guang
JIN Fu
WU Zheng-yan
LI Hui-ming
MIAO Shuang-tao
author_sort JIANG Shu-guang
collection DOAJ
description A distributed measuring system of ventilator performance was used to measure performance of two main ventilators of west airshaft in Dongtan Coal Mine, and curves of blastvolume-air pressure, blastvolume-power and blastvolume-efficiency were drawn according to the measured data. Ventilation abilities of main standby ventilator in different condition and different blade angle were analyzed. The practical application showed that the system greatly reduces time needed for field testing and is effective and accurate in data processing.
first_indexed 2024-04-09T23:55:54Z
format Article
id doaj.art-8e9de72585844b77b4fbdcce3b3d9193
institution Directory Open Access Journal
issn 1671-251X
language zho
last_indexed 2024-04-09T23:55:54Z
publishDate 2011-02-01
publisher Editorial Department of Industry and Mine Automation
record_format Article
series Gong-kuang zidonghua
spelling doaj.art-8e9de72585844b77b4fbdcce3b3d91932023-03-17T02:41:49ZzhoEditorial Department of Industry and Mine AutomationGong-kuang zidonghua1671-251X2011-02-013727780Application of Distributed Measuring System of Ventilator Performance in Coal Mine and Its AnalysisJIANG Shu-guangJIN FuWU Zheng-yanLI Hui-mingMIAO Shuang-taoA distributed measuring system of ventilator performance was used to measure performance of two main ventilators of west airshaft in Dongtan Coal Mine, and curves of blastvolume-air pressure, blastvolume-power and blastvolume-efficiency were drawn according to the measured data. Ventilation abilities of main standby ventilator in different condition and different blade angle were analyzed. The practical application showed that the system greatly reduces time needed for field testing and is effective and accurate in data processing.http://www.gkzdh.cn/article/id/2457mine ventilator, air volume, negative pressure, performance measurement, distributed system
spellingShingle JIANG Shu-guang
JIN Fu
WU Zheng-yan
LI Hui-ming
MIAO Shuang-tao
Application of Distributed Measuring System of Ventilator Performance in Coal Mine and Its Analysis
Gong-kuang zidonghua
mine ventilator, air volume, negative pressure, performance measurement, distributed system
title Application of Distributed Measuring System of Ventilator Performance in Coal Mine and Its Analysis
title_full Application of Distributed Measuring System of Ventilator Performance in Coal Mine and Its Analysis
title_fullStr Application of Distributed Measuring System of Ventilator Performance in Coal Mine and Its Analysis
title_full_unstemmed Application of Distributed Measuring System of Ventilator Performance in Coal Mine and Its Analysis
title_short Application of Distributed Measuring System of Ventilator Performance in Coal Mine and Its Analysis
title_sort application of distributed measuring system of ventilator performance in coal mine and its analysis
topic mine ventilator, air volume, negative pressure, performance measurement, distributed system
url http://www.gkzdh.cn/article/id/2457
work_keys_str_mv AT jiangshuguang applicationofdistributedmeasuringsystemofventilatorperformanceincoalmineanditsanalysis
AT jinfu applicationofdistributedmeasuringsystemofventilatorperformanceincoalmineanditsanalysis
AT wuzhengyan applicationofdistributedmeasuringsystemofventilatorperformanceincoalmineanditsanalysis
AT lihuiming applicationofdistributedmeasuringsystemofventilatorperformanceincoalmineanditsanalysis
AT miaoshuangtao applicationofdistributedmeasuringsystemofventilatorperformanceincoalmineanditsanalysis