Quantitative Analysis of Gap Between the Intraocular Lens and Posterior Capsule Using Microscope-Integrated Optical Coherence Tomography in Eyes Undergoing Phacoemulsification

Ritu Nagpal, Chetan Shakkarwal, Rinky Agarwal, Rahul Kumar Bafna, Prafulla Kumar Maharana, Namrata Sharma Cataract, Cornea & Refractive Surgery Services, Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, IndiaCorrespondence: Namrata Sharm...

Full description

Bibliographic Details
Main Authors: Nagpal R, Shakkarwal C, Agarwal R, Bafna RK, Maharana PK, Sharma N
Format: Article
Language:English
Published: Dove Medical Press 2021-05-01
Series:Clinical Ophthalmology
Subjects:
Online Access:https://www.dovepress.com/quantitative-analysis-of-gap-between-the-intraocular-lens-and-posterio-peer-reviewed-fulltext-article-OPTH
_version_ 1818843334780649472
author Nagpal R
Shakkarwal C
Agarwal R
Bafna RK
Maharana PK
Sharma N
author_facet Nagpal R
Shakkarwal C
Agarwal R
Bafna RK
Maharana PK
Sharma N
author_sort Nagpal R
collection DOAJ
description Ritu Nagpal, Chetan Shakkarwal, Rinky Agarwal, Rahul Kumar Bafna, Prafulla Kumar Maharana, Namrata Sharma Cataract, Cornea & Refractive Surgery Services, Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, IndiaCorrespondence: Namrata SharmaCataract, Cornea & Refractive Surgery Services, Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, IndiaTel +91-11-26593144Email namrata.sharma@gmail.comPurpose: To quantitatively analyze the dimensions of the gap between the intraocular lens (IOL) and the posterior capsule using microscope-integrated optical coherence tomography (MIOCT).Setting: Institutional.Design: Prospective, interventional.Methods: A total of 105 eyes of 105 consecutive patients planned for phacoemulsification with IOL implantation were enrolled. At the end of surgery, the gap between the IOL and the posterior capsule (IOL-PC gap) was measured using MIOCT (RESCAN). The same gap was reassessed at 1 week follow-up visit using the Visante-OCT system. The cases were sub-grouped based on the grade of cataract, IOL material, size and design and were analyzed to look for any difference in the IOL-PC gap both intraoperatively and postoperatively.Results: The IOL-PC gap could be successfully measured intra-operatively in all cases, using the RESCAN. The mean gap at the end of phacoemulsification was 385.08± 264.58 μm, and at one week follow up this was 120.83± 95.13 μm.Conclusion: MIOCT may be successfully used to quantify the dimensions of the gap between the IOL and the posterior capsule. It can be used as a potential tool to further understand the dynamics of the IOL-PC space and to assess the impact of various IOL and non-IOL parameters implicated in the causation of posterior capsule opacification.Keywords: cataract surgery, intraocular lens-posterior capsule gap, microscope-integrated optical coherence tomography, spectral domain optical coherence tomography, RESCAN
first_indexed 2024-12-19T04:56:13Z
format Article
id doaj.art-8ea91689aa064af6a65058cf946b8eae
institution Directory Open Access Journal
issn 1177-5483
language English
last_indexed 2024-12-19T04:56:13Z
publishDate 2021-05-01
publisher Dove Medical Press
record_format Article
series Clinical Ophthalmology
spelling doaj.art-8ea91689aa064af6a65058cf946b8eae2022-12-21T20:35:13ZengDove Medical PressClinical Ophthalmology1177-54832021-05-01Volume 151965197064634Quantitative Analysis of Gap Between the Intraocular Lens and Posterior Capsule Using Microscope-Integrated Optical Coherence Tomography in Eyes Undergoing PhacoemulsificationNagpal RShakkarwal CAgarwal RBafna RKMaharana PKSharma NRitu Nagpal, Chetan Shakkarwal, Rinky Agarwal, Rahul Kumar Bafna, Prafulla Kumar Maharana, Namrata Sharma Cataract, Cornea & Refractive Surgery Services, Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, IndiaCorrespondence: Namrata SharmaCataract, Cornea & Refractive Surgery Services, Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, IndiaTel +91-11-26593144Email namrata.sharma@gmail.comPurpose: To quantitatively analyze the dimensions of the gap between the intraocular lens (IOL) and the posterior capsule using microscope-integrated optical coherence tomography (MIOCT).Setting: Institutional.Design: Prospective, interventional.Methods: A total of 105 eyes of 105 consecutive patients planned for phacoemulsification with IOL implantation were enrolled. At the end of surgery, the gap between the IOL and the posterior capsule (IOL-PC gap) was measured using MIOCT (RESCAN). The same gap was reassessed at 1 week follow-up visit using the Visante-OCT system. The cases were sub-grouped based on the grade of cataract, IOL material, size and design and were analyzed to look for any difference in the IOL-PC gap both intraoperatively and postoperatively.Results: The IOL-PC gap could be successfully measured intra-operatively in all cases, using the RESCAN. The mean gap at the end of phacoemulsification was 385.08± 264.58 μm, and at one week follow up this was 120.83± 95.13 μm.Conclusion: MIOCT may be successfully used to quantify the dimensions of the gap between the IOL and the posterior capsule. It can be used as a potential tool to further understand the dynamics of the IOL-PC space and to assess the impact of various IOL and non-IOL parameters implicated in the causation of posterior capsule opacification.Keywords: cataract surgery, intraocular lens-posterior capsule gap, microscope-integrated optical coherence tomography, spectral domain optical coherence tomography, RESCANhttps://www.dovepress.com/quantitative-analysis-of-gap-between-the-intraocular-lens-and-posterio-peer-reviewed-fulltext-article-OPTHcataract surgeryintraocular lens-posterior capsule gapmicroscope-integrated optical coherence tomographyspectral domain optical coherence tomographyrescan
spellingShingle Nagpal R
Shakkarwal C
Agarwal R
Bafna RK
Maharana PK
Sharma N
Quantitative Analysis of Gap Between the Intraocular Lens and Posterior Capsule Using Microscope-Integrated Optical Coherence Tomography in Eyes Undergoing Phacoemulsification
Clinical Ophthalmology
cataract surgery
intraocular lens-posterior capsule gap
microscope-integrated optical coherence tomography
spectral domain optical coherence tomography
rescan
title Quantitative Analysis of Gap Between the Intraocular Lens and Posterior Capsule Using Microscope-Integrated Optical Coherence Tomography in Eyes Undergoing Phacoemulsification
title_full Quantitative Analysis of Gap Between the Intraocular Lens and Posterior Capsule Using Microscope-Integrated Optical Coherence Tomography in Eyes Undergoing Phacoemulsification
title_fullStr Quantitative Analysis of Gap Between the Intraocular Lens and Posterior Capsule Using Microscope-Integrated Optical Coherence Tomography in Eyes Undergoing Phacoemulsification
title_full_unstemmed Quantitative Analysis of Gap Between the Intraocular Lens and Posterior Capsule Using Microscope-Integrated Optical Coherence Tomography in Eyes Undergoing Phacoemulsification
title_short Quantitative Analysis of Gap Between the Intraocular Lens and Posterior Capsule Using Microscope-Integrated Optical Coherence Tomography in Eyes Undergoing Phacoemulsification
title_sort quantitative analysis of gap between the intraocular lens and posterior capsule using microscope integrated optical coherence tomography in eyes undergoing phacoemulsification
topic cataract surgery
intraocular lens-posterior capsule gap
microscope-integrated optical coherence tomography
spectral domain optical coherence tomography
rescan
url https://www.dovepress.com/quantitative-analysis-of-gap-between-the-intraocular-lens-and-posterio-peer-reviewed-fulltext-article-OPTH
work_keys_str_mv AT nagpalr quantitativeanalysisofgapbetweentheintraocularlensandposteriorcapsuleusingmicroscopeintegratedopticalcoherencetomographyineyesundergoingphacoemulsification
AT shakkarwalc quantitativeanalysisofgapbetweentheintraocularlensandposteriorcapsuleusingmicroscopeintegratedopticalcoherencetomographyineyesundergoingphacoemulsification
AT agarwalr quantitativeanalysisofgapbetweentheintraocularlensandposteriorcapsuleusingmicroscopeintegratedopticalcoherencetomographyineyesundergoingphacoemulsification
AT bafnark quantitativeanalysisofgapbetweentheintraocularlensandposteriorcapsuleusingmicroscopeintegratedopticalcoherencetomographyineyesundergoingphacoemulsification
AT maharanapk quantitativeanalysisofgapbetweentheintraocularlensandposteriorcapsuleusingmicroscopeintegratedopticalcoherencetomographyineyesundergoingphacoemulsification
AT sharman quantitativeanalysisofgapbetweentheintraocularlensandposteriorcapsuleusingmicroscopeintegratedopticalcoherencetomographyineyesundergoingphacoemulsification