Analytical Quality by Design: Achieving Robustness of an LC-CAD Method for the Analysis of Non-Volatile Fatty Acids

An alternative to the time-consuming and error-prone pharmacopoeial gas chromatography method for the analysis of fatty acids (FAs) is urgently needed. The objective was therefore to propose a robust liquid chromatography method with charged aerosol detection for the analysis of polysorbate 80 (PS80...

Full description

Bibliographic Details
Main Authors: Rasmus Walther, Jovana Krmar, Adrian Leistner, Bojana Svrkota, Biljana Otašević, Andjelija Malenović, Ulrike Holzgrabe, Ana Protić
Format: Article
Language:English
Published: MDPI AG 2023-03-01
Series:Pharmaceuticals
Subjects:
Online Access:https://www.mdpi.com/1424-8247/16/4/478
_version_ 1827744048455090176
author Rasmus Walther
Jovana Krmar
Adrian Leistner
Bojana Svrkota
Biljana Otašević
Andjelija Malenović
Ulrike Holzgrabe
Ana Protić
author_facet Rasmus Walther
Jovana Krmar
Adrian Leistner
Bojana Svrkota
Biljana Otašević
Andjelija Malenović
Ulrike Holzgrabe
Ana Protić
author_sort Rasmus Walther
collection DOAJ
description An alternative to the time-consuming and error-prone pharmacopoeial gas chromatography method for the analysis of fatty acids (FAs) is urgently needed. The objective was therefore to propose a robust liquid chromatography method with charged aerosol detection for the analysis of polysorbate 80 (PS80) and magnesium stearate. FAs with different numbers of carbon atoms in the chain necessitated the use of a gradient method with a Hypersil Gold C<sub>18</sub> column and acetonitrile as organic modifier. The risk-based Analytical Quality by Design approach was applied to define the Method Operable Design Region (MODR). Formic acid concentration, initial and final percentages of acetonitrile, gradient elution time, column temperature, and mobile phase flow rate were identified as critical method parameters (CMPs). The initial and final percentages of acetonitrile were fixed while the remaining CMPs were fine-tuned using response surface methodology. Critical method attributes included the baseline separation of adjacent peaks (α-linolenic and myristic acid, and oleic and petroselinic acid) and the retention factor of the last compound eluted, stearic acid. The MODR was calculated by Monte Carlo simulations with a probability equal or greater than 90%. Finally, the column temperature was set at 33 °C, the flow rate was 0.575 mL/min, and acetonitrile linearly increased from 70 to 80% (<i>v</i>/<i>v</i>) within 14.2 min.
first_indexed 2024-03-11T04:39:28Z
format Article
id doaj.art-8ef32e416f0b4464afdde9d101cbad72
institution Directory Open Access Journal
issn 1424-8247
language English
last_indexed 2024-03-11T04:39:28Z
publishDate 2023-03-01
publisher MDPI AG
record_format Article
series Pharmaceuticals
spelling doaj.art-8ef32e416f0b4464afdde9d101cbad722023-11-17T20:49:30ZengMDPI AGPharmaceuticals1424-82472023-03-0116447810.3390/ph16040478Analytical Quality by Design: Achieving Robustness of an LC-CAD Method for the Analysis of Non-Volatile Fatty AcidsRasmus Walther0Jovana Krmar1Adrian Leistner2Bojana Svrkota3Biljana Otašević4Andjelija Malenović5Ulrike Holzgrabe6Ana Protić7Institute for Pharmacy and Food Chemistry, University of Würzburg, Am Hubland, 97074 Würzburg, GermanyDepartment of Drug Analysis, Faculty of Pharmacy, University of Belgrade, Vojvode Stepe 450, 11 221 Belgrade, SerbiaInstitute for Pharmacy and Food Chemistry, University of Würzburg, Am Hubland, 97074 Würzburg, GermanyDepartment of Drug Analysis, Faculty of Pharmacy, University of Belgrade, Vojvode Stepe 450, 11 221 Belgrade, SerbiaDepartment of Drug Analysis, Faculty of Pharmacy, University of Belgrade, Vojvode Stepe 450, 11 221 Belgrade, SerbiaDepartment of Drug Analysis, Faculty of Pharmacy, University of Belgrade, Vojvode Stepe 450, 11 221 Belgrade, SerbiaInstitute for Pharmacy and Food Chemistry, University of Würzburg, Am Hubland, 97074 Würzburg, GermanyDepartment of Drug Analysis, Faculty of Pharmacy, University of Belgrade, Vojvode Stepe 450, 11 221 Belgrade, SerbiaAn alternative to the time-consuming and error-prone pharmacopoeial gas chromatography method for the analysis of fatty acids (FAs) is urgently needed. The objective was therefore to propose a robust liquid chromatography method with charged aerosol detection for the analysis of polysorbate 80 (PS80) and magnesium stearate. FAs with different numbers of carbon atoms in the chain necessitated the use of a gradient method with a Hypersil Gold C<sub>18</sub> column and acetonitrile as organic modifier. The risk-based Analytical Quality by Design approach was applied to define the Method Operable Design Region (MODR). Formic acid concentration, initial and final percentages of acetonitrile, gradient elution time, column temperature, and mobile phase flow rate were identified as critical method parameters (CMPs). The initial and final percentages of acetonitrile were fixed while the remaining CMPs were fine-tuned using response surface methodology. Critical method attributes included the baseline separation of adjacent peaks (α-linolenic and myristic acid, and oleic and petroselinic acid) and the retention factor of the last compound eluted, stearic acid. The MODR was calculated by Monte Carlo simulations with a probability equal or greater than 90%. Finally, the column temperature was set at 33 °C, the flow rate was 0.575 mL/min, and acetonitrile linearly increased from 70 to 80% (<i>v</i>/<i>v</i>) within 14.2 min.https://www.mdpi.com/1424-8247/16/4/478Analytical Quality by Designfatty acidscharged aerosol detectorpolysorbate 80magnesium stearate
spellingShingle Rasmus Walther
Jovana Krmar
Adrian Leistner
Bojana Svrkota
Biljana Otašević
Andjelija Malenović
Ulrike Holzgrabe
Ana Protić
Analytical Quality by Design: Achieving Robustness of an LC-CAD Method for the Analysis of Non-Volatile Fatty Acids
Pharmaceuticals
Analytical Quality by Design
fatty acids
charged aerosol detector
polysorbate 80
magnesium stearate
title Analytical Quality by Design: Achieving Robustness of an LC-CAD Method for the Analysis of Non-Volatile Fatty Acids
title_full Analytical Quality by Design: Achieving Robustness of an LC-CAD Method for the Analysis of Non-Volatile Fatty Acids
title_fullStr Analytical Quality by Design: Achieving Robustness of an LC-CAD Method for the Analysis of Non-Volatile Fatty Acids
title_full_unstemmed Analytical Quality by Design: Achieving Robustness of an LC-CAD Method for the Analysis of Non-Volatile Fatty Acids
title_short Analytical Quality by Design: Achieving Robustness of an LC-CAD Method for the Analysis of Non-Volatile Fatty Acids
title_sort analytical quality by design achieving robustness of an lc cad method for the analysis of non volatile fatty acids
topic Analytical Quality by Design
fatty acids
charged aerosol detector
polysorbate 80
magnesium stearate
url https://www.mdpi.com/1424-8247/16/4/478
work_keys_str_mv AT rasmuswalther analyticalqualitybydesignachievingrobustnessofanlccadmethodfortheanalysisofnonvolatilefattyacids
AT jovanakrmar analyticalqualitybydesignachievingrobustnessofanlccadmethodfortheanalysisofnonvolatilefattyacids
AT adrianleistner analyticalqualitybydesignachievingrobustnessofanlccadmethodfortheanalysisofnonvolatilefattyacids
AT bojanasvrkota analyticalqualitybydesignachievingrobustnessofanlccadmethodfortheanalysisofnonvolatilefattyacids
AT biljanaotasevic analyticalqualitybydesignachievingrobustnessofanlccadmethodfortheanalysisofnonvolatilefattyacids
AT andjelijamalenovic analyticalqualitybydesignachievingrobustnessofanlccadmethodfortheanalysisofnonvolatilefattyacids
AT ulrikeholzgrabe analyticalqualitybydesignachievingrobustnessofanlccadmethodfortheanalysisofnonvolatilefattyacids
AT anaprotic analyticalqualitybydesignachievingrobustnessofanlccadmethodfortheanalysisofnonvolatilefattyacids