Indoor thermal comfort in different building blocks

This paper discusses the energy and comfort impact of three types of urban block configuration in the Netherlands. The annual heating and lighting energy demand, and summer thermal comfort hours are compared. In total, 102 thermal zones forming single, linear and courtyard building combinations are...

Full description

Bibliographic Details
Main Authors: Mohammad Taleghani, Martin Tenpierik, Andy van den Dobbelsteen
Format: Article
Language:English
Published: Delft University of Technology 2014-12-01
Series:A+BE: Architecture and the Built Environment
Subjects:
Online Access:https://journals.open.tudelft.nl/abe/article/view/6578
Description
Summary:This paper discusses the energy and comfort impact of three types of urban block configuration in the Netherlands. The annual heating and lighting energy demand, and summer thermal comfort hours are compared. In total, 102 thermal zones forming single, linear and courtyard building combinations are simulated within the Netherlands’ temperate climate. The results demonstrate the importance of the surfaceto- volume ratio in achieving both annual energy ef ficiency and summer thermal comfort. Considering different types with 1-, 2- and 3-storey heights, the courtyard model has the lowest energy demand for heating and the highest number of summer thermal comfort hours.
ISSN:2212-3202
2214-7233