New methodology to diagnose reliability of a single distribution circuit in Colombia

A reliable electric power supply is of ever increasing importance in the Colombian electricity market. As such, the Energy and Gas Regulation Commission, (CREG for its acronym in Spanish), has contracted technical studies to be undertaken in order to assess reliability for Colombian electric utiliti...

Full description

Bibliographic Details
Main Authors: Jorge Alberto Echeverry-Herrera, Carlos Arturo Lozano-Moncada
Format: Article
Language:English
Published: Universidad Nacional de Colombia 2017-05-01
Series:Dyna
Subjects:
Online Access:https://revistas.unal.edu.co/index.php/dyna/article/view/54330
_version_ 1811252899631595520
author Jorge Alberto Echeverry-Herrera
Carlos Arturo Lozano-Moncada
author_facet Jorge Alberto Echeverry-Herrera
Carlos Arturo Lozano-Moncada
author_sort Jorge Alberto Echeverry-Herrera
collection DOAJ
description A reliable electric power supply is of ever increasing importance in the Colombian electricity market. As such, the Energy and Gas Regulation Commission, (CREG for its acronym in Spanish), has contracted technical studies to be undertaken in order to assess reliability for Colombian electric utilities. This paper focuses on a new methodology to diagnose the reliability of a single distribution circuit that is to be used in Colombian electric utilities. The proposed methodology includes calculating known reliability indexes (SAIFI, SAIDI, CAIDI, etc.) as well as new reliability indexes in order to determine the incidence of causes of failure. This paper explains some of the required files´ characteristics (input and output files) in order to execute two applications associated with the previously mentioned methodology. These two applications were developed using Microsoft Excel for the Strategic Energy Business Unit at EMCALI EICE ESP, located on Santiago de Cali, Valle del Cauca, Colombia, South America. This article describes some features of these applications. The first case study presented, about the first application, is calculated based on this methodology, and results obtained are compared with those obtained using ETAP software. Finally, the second case study, regarding the second application, is calculated based on this methodology and results obtained are shown in this document.
first_indexed 2024-04-12T16:41:34Z
format Article
id doaj.art-8f83a9d87d2b45b59ab2be0280dc424f
institution Directory Open Access Journal
issn 0012-7353
2346-2183
language English
last_indexed 2024-04-12T16:41:34Z
publishDate 2017-05-01
publisher Universidad Nacional de Colombia
record_format Article
series Dyna
spelling doaj.art-8f83a9d87d2b45b59ab2be0280dc424f2022-12-22T03:24:46ZengUniversidad Nacional de ColombiaDyna0012-73532346-21832017-05-0184201748110.15446/dyna.v84n201.5433045618New methodology to diagnose reliability of a single distribution circuit in ColombiaJorge Alberto Echeverry-Herrera0Carlos Arturo Lozano-Moncada1Universidad del ValleUniversidad del ValleA reliable electric power supply is of ever increasing importance in the Colombian electricity market. As such, the Energy and Gas Regulation Commission, (CREG for its acronym in Spanish), has contracted technical studies to be undertaken in order to assess reliability for Colombian electric utilities. This paper focuses on a new methodology to diagnose the reliability of a single distribution circuit that is to be used in Colombian electric utilities. The proposed methodology includes calculating known reliability indexes (SAIFI, SAIDI, CAIDI, etc.) as well as new reliability indexes in order to determine the incidence of causes of failure. This paper explains some of the required files´ characteristics (input and output files) in order to execute two applications associated with the previously mentioned methodology. These two applications were developed using Microsoft Excel for the Strategic Energy Business Unit at EMCALI EICE ESP, located on Santiago de Cali, Valle del Cauca, Colombia, South America. This article describes some features of these applications. The first case study presented, about the first application, is calculated based on this methodology, and results obtained are compared with those obtained using ETAP software. Finally, the second case study, regarding the second application, is calculated based on this methodology and results obtained are shown in this document.https://revistas.unal.edu.co/index.php/dyna/article/view/54330Assess reliabilityColombian electric utilitiesmethodologydiagnose the reliabilitysingle distribution circuitreliability indexescauses of failurefilesapplicationsMicrosoft ExcelEMCALI EICE ESPcase studyETAP software
spellingShingle Jorge Alberto Echeverry-Herrera
Carlos Arturo Lozano-Moncada
New methodology to diagnose reliability of a single distribution circuit in Colombia
Dyna
Assess reliability
Colombian electric utilities
methodology
diagnose the reliability
single distribution circuit
reliability indexes
causes of failure
files
applications
Microsoft Excel
EMCALI EICE ESP
case study
ETAP software
title New methodology to diagnose reliability of a single distribution circuit in Colombia
title_full New methodology to diagnose reliability of a single distribution circuit in Colombia
title_fullStr New methodology to diagnose reliability of a single distribution circuit in Colombia
title_full_unstemmed New methodology to diagnose reliability of a single distribution circuit in Colombia
title_short New methodology to diagnose reliability of a single distribution circuit in Colombia
title_sort new methodology to diagnose reliability of a single distribution circuit in colombia
topic Assess reliability
Colombian electric utilities
methodology
diagnose the reliability
single distribution circuit
reliability indexes
causes of failure
files
applications
Microsoft Excel
EMCALI EICE ESP
case study
ETAP software
url https://revistas.unal.edu.co/index.php/dyna/article/view/54330
work_keys_str_mv AT jorgealbertoecheverryherrera newmethodologytodiagnosereliabilityofasingledistributioncircuitincolombia
AT carlosarturolozanomoncada newmethodologytodiagnosereliabilityofasingledistributioncircuitincolombia