A standard formulation for the installation of suction caissons in sand

Suction assisted installation of caisson foundations in sand relies on the developed seepage around the caisson wall. Seepage is known to produce soil loosening inside the caisson cavity and an overall reduction in soil resistance to caisson penetration. On the other hand, suction must be controlled...

Full description

Bibliographic Details
Main Authors: Ayed Eid Alluqmani, Muhammad Tayyab Naqash, Ouahid Harireche
Format: Article
Language:English
Published: Elsevier 2019-12-01
Series:Journal of Ocean Engineering and Science
Online Access:http://www.sciencedirect.com/science/article/pii/S2468013319301226
_version_ 1811317099731091456
author Ayed Eid Alluqmani
Muhammad Tayyab Naqash
Ouahid Harireche
author_facet Ayed Eid Alluqmani
Muhammad Tayyab Naqash
Ouahid Harireche
author_sort Ayed Eid Alluqmani
collection DOAJ
description Suction assisted installation of caisson foundations in sand relies on the developed seepage around the caisson wall. Seepage is known to produce soil loosening inside the caisson cavity and an overall reduction in soil resistance to caisson penetration. On the other hand, suction must be controlled so that no excessive piping is induced within the sand volume trapped inside the caisson cavity. When it extends over the full embedded length of the caisson wall, piping may lead to the formation of piping channels, which may compromise the established seal between caisson and soil and ultimately cause the installation process to stop. A safe installation process requires a proper design procedure to ensure that a safe suction can be predicted prior to installation. The present paper provides a framework where analytical expressions are obtained for the required suction magnitude, and for the critical suction that causes piping to initiate at the caisson tip. These analytical expressions are derived for a normalized caisson geometry, based on compiled results obtained from finite element analysis of seepage around a caisson wall, at various installation depths. The developed analytical formulation applies independently of caisson dimensions such as diameter, height and wall thickness. Critical suction for piping condition is also obtained under analytical form as a function of normalized penetration depth. The developed formulation can also be easily incorporated into design procedures or used in design codes without a need for a preliminary seepage analysis to be undertaken. The proposed suction predictions for the whole process of caisson installation in sand are validated against field trials reported in the literature. Keywords: Suction caisson, Normalized seepage problem, Polynomial regressions, Suction profile, Critical suction for piping
first_indexed 2024-04-13T12:00:40Z
format Article
id doaj.art-8f97c22b3e8d4a86a73cde4c256c1f33
institution Directory Open Access Journal
issn 2468-0133
language English
last_indexed 2024-04-13T12:00:40Z
publishDate 2019-12-01
publisher Elsevier
record_format Article
series Journal of Ocean Engineering and Science
spelling doaj.art-8f97c22b3e8d4a86a73cde4c256c1f332022-12-22T02:47:47ZengElsevierJournal of Ocean Engineering and Science2468-01332019-12-0144395405A standard formulation for the installation of suction caissons in sandAyed Eid Alluqmani0Muhammad Tayyab Naqash1Ouahid Harireche2Department of Civil Engineering, Faculty of Engineering, Islamic University of Madinah, Madinah, Saudi ArabiaCorresponding author.; Department of Civil Engineering, Faculty of Engineering, Islamic University of Madinah, Madinah, Saudi ArabiaDepartment of Civil Engineering, Faculty of Engineering, Islamic University of Madinah, Madinah, Saudi ArabiaSuction assisted installation of caisson foundations in sand relies on the developed seepage around the caisson wall. Seepage is known to produce soil loosening inside the caisson cavity and an overall reduction in soil resistance to caisson penetration. On the other hand, suction must be controlled so that no excessive piping is induced within the sand volume trapped inside the caisson cavity. When it extends over the full embedded length of the caisson wall, piping may lead to the formation of piping channels, which may compromise the established seal between caisson and soil and ultimately cause the installation process to stop. A safe installation process requires a proper design procedure to ensure that a safe suction can be predicted prior to installation. The present paper provides a framework where analytical expressions are obtained for the required suction magnitude, and for the critical suction that causes piping to initiate at the caisson tip. These analytical expressions are derived for a normalized caisson geometry, based on compiled results obtained from finite element analysis of seepage around a caisson wall, at various installation depths. The developed analytical formulation applies independently of caisson dimensions such as diameter, height and wall thickness. Critical suction for piping condition is also obtained under analytical form as a function of normalized penetration depth. The developed formulation can also be easily incorporated into design procedures or used in design codes without a need for a preliminary seepage analysis to be undertaken. The proposed suction predictions for the whole process of caisson installation in sand are validated against field trials reported in the literature. Keywords: Suction caisson, Normalized seepage problem, Polynomial regressions, Suction profile, Critical suction for pipinghttp://www.sciencedirect.com/science/article/pii/S2468013319301226
spellingShingle Ayed Eid Alluqmani
Muhammad Tayyab Naqash
Ouahid Harireche
A standard formulation for the installation of suction caissons in sand
Journal of Ocean Engineering and Science
title A standard formulation for the installation of suction caissons in sand
title_full A standard formulation for the installation of suction caissons in sand
title_fullStr A standard formulation for the installation of suction caissons in sand
title_full_unstemmed A standard formulation for the installation of suction caissons in sand
title_short A standard formulation for the installation of suction caissons in sand
title_sort standard formulation for the installation of suction caissons in sand
url http://www.sciencedirect.com/science/article/pii/S2468013319301226
work_keys_str_mv AT ayedeidalluqmani astandardformulationfortheinstallationofsuctioncaissonsinsand
AT muhammadtayyabnaqash astandardformulationfortheinstallationofsuctioncaissonsinsand
AT ouahidharireche astandardformulationfortheinstallationofsuctioncaissonsinsand
AT ayedeidalluqmani standardformulationfortheinstallationofsuctioncaissonsinsand
AT muhammadtayyabnaqash standardformulationfortheinstallationofsuctioncaissonsinsand
AT ouahidharireche standardformulationfortheinstallationofsuctioncaissonsinsand