Heterocyclic aromatic amines in doner kebab: Quantitation using an efficient microextraction technique coupled with reversed‐phase high‐performance liquid chromatography

Abstract The safety of doner kebab as a traditional Middle East tasty food can threaten via the formation of dangerous compounds such as heterocyclic aromatic amines during heat process. In this regard, the current investigation was devoted to measuring of 4 HAAs (2‐amino‐3,4‐dimethylimidazo[4,5‐f]q...

Full description

Bibliographic Details
Main Authors: Abdorreza Mohammadi, Fatemeh Barzegar, Marzieh Kamankesh, Amin Mousavi Khaneghah
Format: Article
Language:English
Published: Wiley 2020-01-01
Series:Food Science & Nutrition
Subjects:
Online Access:https://doi.org/10.1002/fsn3.1262
_version_ 1797221356804243456
author Abdorreza Mohammadi
Fatemeh Barzegar
Marzieh Kamankesh
Amin Mousavi Khaneghah
author_facet Abdorreza Mohammadi
Fatemeh Barzegar
Marzieh Kamankesh
Amin Mousavi Khaneghah
author_sort Abdorreza Mohammadi
collection DOAJ
description Abstract The safety of doner kebab as a traditional Middle East tasty food can threaten via the formation of dangerous compounds such as heterocyclic aromatic amines during heat process. In this regard, the current investigation was devoted to measuring of 4 HAAs (2‐amino‐3,4‐dimethylimidazo[4,5‐f]quinoline (MeIQ), 2‐amino‐3,8‐dimethylimidazo[4,5‐f]quinoxaline (MeIQx), 2‐amino‐1‐methyl‐6‐phenylimidazo[4,5‐b]pyridine (PhIP), and 2‐amino‐3‐methylimidazo[4,5‐f]quinoline (IQ)) in doner kebab samples with an innovative microextraction technique combined with high‐performance liquid chromatography. The limit of detection was in the range of 4.8 and 5.3 ng/g, while relative standard deviations were between 6.5% and 8.3%, and recoveries were calculated in the range of 89%–97%. The most and the least total mean values of HAA levels were 13.30 ng/g for MeIQx and 5.0 ng/g for IQ. The proposed method showed a high capability to extract trace amount of HAAs from a complex matrix such as doner kebab. Also, this technique is easy, high sensitive, selective, accurate and efficient.
first_indexed 2024-04-24T13:04:08Z
format Article
id doaj.art-90274a73a25f4f4c94c9e5c789c85e9c
institution Directory Open Access Journal
issn 2048-7177
language English
last_indexed 2024-04-24T13:04:08Z
publishDate 2020-01-01
publisher Wiley
record_format Article
series Food Science & Nutrition
spelling doaj.art-90274a73a25f4f4c94c9e5c789c85e9c2024-04-05T09:16:02ZengWileyFood Science & Nutrition2048-71772020-01-0181889610.1002/fsn3.1262Heterocyclic aromatic amines in doner kebab: Quantitation using an efficient microextraction technique coupled with reversed‐phase high‐performance liquid chromatographyAbdorreza Mohammadi0Fatemeh Barzegar1Marzieh Kamankesh2Amin Mousavi Khaneghah3Department of Food Science and Technology Faculty of Nutrition Science Food Science and Technology/National Nutrition and Food Technology Research Institute Shahid Beheshti University of Medical Sciences Tehran IranDepartment of Food Science and Technology Faculty of Nutrition Science Food Science and Technology/National Nutrition and Food Technology Research Institute Shahid Beheshti University of Medical Sciences Tehran IranDepartment of Food Science and Technology Faculty of Nutrition Science Food Science and Technology/National Nutrition and Food Technology Research Institute Shahid Beheshti University of Medical Sciences Tehran IranDepartment of Food Science Faculty of Food Engineering University of Campinas (UNICAMP) Campinas São Paulo BrazilAbstract The safety of doner kebab as a traditional Middle East tasty food can threaten via the formation of dangerous compounds such as heterocyclic aromatic amines during heat process. In this regard, the current investigation was devoted to measuring of 4 HAAs (2‐amino‐3,4‐dimethylimidazo[4,5‐f]quinoline (MeIQ), 2‐amino‐3,8‐dimethylimidazo[4,5‐f]quinoxaline (MeIQx), 2‐amino‐1‐methyl‐6‐phenylimidazo[4,5‐b]pyridine (PhIP), and 2‐amino‐3‐methylimidazo[4,5‐f]quinoline (IQ)) in doner kebab samples with an innovative microextraction technique combined with high‐performance liquid chromatography. The limit of detection was in the range of 4.8 and 5.3 ng/g, while relative standard deviations were between 6.5% and 8.3%, and recoveries were calculated in the range of 89%–97%. The most and the least total mean values of HAA levels were 13.30 ng/g for MeIQx and 5.0 ng/g for IQ. The proposed method showed a high capability to extract trace amount of HAAs from a complex matrix such as doner kebab. Also, this technique is easy, high sensitive, selective, accurate and efficient.https://doi.org/10.1002/fsn3.1262central composite designdoner kebabHeterocyclic aromatic aminesinstrumental analysismeat productmicroextraction
spellingShingle Abdorreza Mohammadi
Fatemeh Barzegar
Marzieh Kamankesh
Amin Mousavi Khaneghah
Heterocyclic aromatic amines in doner kebab: Quantitation using an efficient microextraction technique coupled with reversed‐phase high‐performance liquid chromatography
Food Science & Nutrition
central composite design
doner kebab
Heterocyclic aromatic amines
instrumental analysis
meat product
microextraction
title Heterocyclic aromatic amines in doner kebab: Quantitation using an efficient microextraction technique coupled with reversed‐phase high‐performance liquid chromatography
title_full Heterocyclic aromatic amines in doner kebab: Quantitation using an efficient microextraction technique coupled with reversed‐phase high‐performance liquid chromatography
title_fullStr Heterocyclic aromatic amines in doner kebab: Quantitation using an efficient microextraction technique coupled with reversed‐phase high‐performance liquid chromatography
title_full_unstemmed Heterocyclic aromatic amines in doner kebab: Quantitation using an efficient microextraction technique coupled with reversed‐phase high‐performance liquid chromatography
title_short Heterocyclic aromatic amines in doner kebab: Quantitation using an efficient microextraction technique coupled with reversed‐phase high‐performance liquid chromatography
title_sort heterocyclic aromatic amines in doner kebab quantitation using an efficient microextraction technique coupled with reversed phase high performance liquid chromatography
topic central composite design
doner kebab
Heterocyclic aromatic amines
instrumental analysis
meat product
microextraction
url https://doi.org/10.1002/fsn3.1262
work_keys_str_mv AT abdorrezamohammadi heterocyclicaromaticaminesindonerkebabquantitationusinganefficientmicroextractiontechniquecoupledwithreversedphasehighperformanceliquidchromatography
AT fatemehbarzegar heterocyclicaromaticaminesindonerkebabquantitationusinganefficientmicroextractiontechniquecoupledwithreversedphasehighperformanceliquidchromatography
AT marziehkamankesh heterocyclicaromaticaminesindonerkebabquantitationusinganefficientmicroextractiontechniquecoupledwithreversedphasehighperformanceliquidchromatography
AT aminmousavikhaneghah heterocyclicaromaticaminesindonerkebabquantitationusinganefficientmicroextractiontechniquecoupledwithreversedphasehighperformanceliquidchromatography