An Innovative Clinical Evaluation Protocol after Total Ankle Arthroplasty: A Pilot Study Using Inertial Sensors and Baropodometric Platforms

Background: Total ankle arthroplasty (TAA) has grown in popularity and indications, with encouraging results over time. Today, preoperative and postoperative evaluations are mainly performed using clinical test and diagnostic imaging, but there is a deficiency in objectively evaluating the biomechan...

Full description

Bibliographic Details
Main Authors: Antonio Mazzotti, Alberto Arceri, Pejman Abdi, Elena Artioli, Simone Ottavio Zielli, Laura Langone, Laura Ramponi, Arianna Ridolfi, Cesare Faldini, Lorenzo Brognara
Format: Article
Language:English
Published: MDPI AG 2024-02-01
Series:Applied Sciences
Subjects:
Online Access:https://www.mdpi.com/2076-3417/14/5/1964
_version_ 1797264858970849280
author Antonio Mazzotti
Alberto Arceri
Pejman Abdi
Elena Artioli
Simone Ottavio Zielli
Laura Langone
Laura Ramponi
Arianna Ridolfi
Cesare Faldini
Lorenzo Brognara
author_facet Antonio Mazzotti
Alberto Arceri
Pejman Abdi
Elena Artioli
Simone Ottavio Zielli
Laura Langone
Laura Ramponi
Arianna Ridolfi
Cesare Faldini
Lorenzo Brognara
author_sort Antonio Mazzotti
collection DOAJ
description Background: Total ankle arthroplasty (TAA) has grown in popularity and indications, with encouraging results over time. Today, preoperative and postoperative evaluations are mainly performed using clinical test and diagnostic imaging, but there is a deficiency in objectively evaluating the biomechanics of the foot and ankle, which serve as the functional markers for monitoring the effectiveness and outcomes of surgery. Inertial measurement units associated with plantar pressure measurements may provide an accurate and reliable method of evaluating function through the analysis of gait and ankle joint mobility. The aim of this study was to introduce an innovative technology, to assess its accuracy and feasibility compared to standard clinical assessment methods and to objectify kinematic outcomes in patients with end-stage ankle OA before and after TAA surgery. Methods: A consecutive series of eight patients with symptomatic end-stage osteoarthritis and treated with TAA was prospectively evaluated using clinical scores (AOFAS, MOxFQ, VAS, SF-36, 17-IFFI), physical tests (FPI, ALT), plantar pressure measurements with FLEX EPS/R2 Letsense<sup>®</sup> baropodometric platform, gait analysis and wearable sensors-based ankle motion and kinematic outcomes using Wiva Science inertial sensors by Letsense<sup>®</sup>. Data were collected preoperatively and 4 months after surgery. Results: All PROMs exhibited statistical significance in improvement from pre- to postoperative periods, except for one. Physical examinations showed no significant changes of the foot shape and alignment. Plantar pressure analyses revealed no significant changes in static and dynamic evaluations, but a more uniform distribution of plantar pressure was observed between the two periods. Inertial sensor parameters demonstrated no significant differences, except for a significant reduction in stride length and step length for the operated foot after surgery. Conclusions: Gait analysis using inertial sensors and plantar pressure measurements offer ease of handling, cost effectiveness, portability and swift data reading, making them highly appealing for widespread clinical use. Integrating these tools into the routine assessments of patients with TAA holds promise for advancing precision of treating this condition and our depth of its understanding, contributing to more comprehensive and insightful patient care.
first_indexed 2024-04-25T00:35:35Z
format Article
id doaj.art-902b71a597df4e86a7be85157bc7a75c
institution Directory Open Access Journal
issn 2076-3417
language English
last_indexed 2024-04-25T00:35:35Z
publishDate 2024-02-01
publisher MDPI AG
record_format Article
series Applied Sciences
spelling doaj.art-902b71a597df4e86a7be85157bc7a75c2024-03-12T16:39:36ZengMDPI AGApplied Sciences2076-34172024-02-01145196410.3390/app14051964An Innovative Clinical Evaluation Protocol after Total Ankle Arthroplasty: A Pilot Study Using Inertial Sensors and Baropodometric PlatformsAntonio Mazzotti0Alberto Arceri1Pejman Abdi2Elena Artioli3Simone Ottavio Zielli4Laura Langone5Laura Ramponi6Arianna Ridolfi7Cesare Faldini8Lorenzo Brognara91st Orthopaedics and Traumatologic Clinic, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy1st Orthopaedics and Traumatologic Clinic, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy1st Orthopaedics and Traumatologic Clinic, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy1st Orthopaedics and Traumatologic Clinic, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy1st Orthopaedics and Traumatologic Clinic, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy1st Orthopaedics and Traumatologic Clinic, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy1st Orthopaedics and Traumatologic Clinic, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, ItalyDepartment of Biomedical and Neuromotor Sciences (DIBINEM), Alma Mater Studiorum University of Bologna, 40123 Bologna, Italy1st Orthopaedics and Traumatologic Clinic, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, ItalyDepartment of Biomedical and Neuromotor Sciences (DIBINEM), Alma Mater Studiorum University of Bologna, 40123 Bologna, ItalyBackground: Total ankle arthroplasty (TAA) has grown in popularity and indications, with encouraging results over time. Today, preoperative and postoperative evaluations are mainly performed using clinical test and diagnostic imaging, but there is a deficiency in objectively evaluating the biomechanics of the foot and ankle, which serve as the functional markers for monitoring the effectiveness and outcomes of surgery. Inertial measurement units associated with plantar pressure measurements may provide an accurate and reliable method of evaluating function through the analysis of gait and ankle joint mobility. The aim of this study was to introduce an innovative technology, to assess its accuracy and feasibility compared to standard clinical assessment methods and to objectify kinematic outcomes in patients with end-stage ankle OA before and after TAA surgery. Methods: A consecutive series of eight patients with symptomatic end-stage osteoarthritis and treated with TAA was prospectively evaluated using clinical scores (AOFAS, MOxFQ, VAS, SF-36, 17-IFFI), physical tests (FPI, ALT), plantar pressure measurements with FLEX EPS/R2 Letsense<sup>®</sup> baropodometric platform, gait analysis and wearable sensors-based ankle motion and kinematic outcomes using Wiva Science inertial sensors by Letsense<sup>®</sup>. Data were collected preoperatively and 4 months after surgery. Results: All PROMs exhibited statistical significance in improvement from pre- to postoperative periods, except for one. Physical examinations showed no significant changes of the foot shape and alignment. Plantar pressure analyses revealed no significant changes in static and dynamic evaluations, but a more uniform distribution of plantar pressure was observed between the two periods. Inertial sensor parameters demonstrated no significant differences, except for a significant reduction in stride length and step length for the operated foot after surgery. Conclusions: Gait analysis using inertial sensors and plantar pressure measurements offer ease of handling, cost effectiveness, portability and swift data reading, making them highly appealing for widespread clinical use. Integrating these tools into the routine assessments of patients with TAA holds promise for advancing precision of treating this condition and our depth of its understanding, contributing to more comprehensive and insightful patient care.https://www.mdpi.com/2076-3417/14/5/1964gait analysisinertial sensorstotal ankle arthroplasty
spellingShingle Antonio Mazzotti
Alberto Arceri
Pejman Abdi
Elena Artioli
Simone Ottavio Zielli
Laura Langone
Laura Ramponi
Arianna Ridolfi
Cesare Faldini
Lorenzo Brognara
An Innovative Clinical Evaluation Protocol after Total Ankle Arthroplasty: A Pilot Study Using Inertial Sensors and Baropodometric Platforms
Applied Sciences
gait analysis
inertial sensors
total ankle arthroplasty
title An Innovative Clinical Evaluation Protocol after Total Ankle Arthroplasty: A Pilot Study Using Inertial Sensors and Baropodometric Platforms
title_full An Innovative Clinical Evaluation Protocol after Total Ankle Arthroplasty: A Pilot Study Using Inertial Sensors and Baropodometric Platforms
title_fullStr An Innovative Clinical Evaluation Protocol after Total Ankle Arthroplasty: A Pilot Study Using Inertial Sensors and Baropodometric Platforms
title_full_unstemmed An Innovative Clinical Evaluation Protocol after Total Ankle Arthroplasty: A Pilot Study Using Inertial Sensors and Baropodometric Platforms
title_short An Innovative Clinical Evaluation Protocol after Total Ankle Arthroplasty: A Pilot Study Using Inertial Sensors and Baropodometric Platforms
title_sort innovative clinical evaluation protocol after total ankle arthroplasty a pilot study using inertial sensors and baropodometric platforms
topic gait analysis
inertial sensors
total ankle arthroplasty
url https://www.mdpi.com/2076-3417/14/5/1964
work_keys_str_mv AT antoniomazzotti aninnovativeclinicalevaluationprotocolaftertotalanklearthroplastyapilotstudyusinginertialsensorsandbaropodometricplatforms
AT albertoarceri aninnovativeclinicalevaluationprotocolaftertotalanklearthroplastyapilotstudyusinginertialsensorsandbaropodometricplatforms
AT pejmanabdi aninnovativeclinicalevaluationprotocolaftertotalanklearthroplastyapilotstudyusinginertialsensorsandbaropodometricplatforms
AT elenaartioli aninnovativeclinicalevaluationprotocolaftertotalanklearthroplastyapilotstudyusinginertialsensorsandbaropodometricplatforms
AT simoneottaviozielli aninnovativeclinicalevaluationprotocolaftertotalanklearthroplastyapilotstudyusinginertialsensorsandbaropodometricplatforms
AT lauralangone aninnovativeclinicalevaluationprotocolaftertotalanklearthroplastyapilotstudyusinginertialsensorsandbaropodometricplatforms
AT lauraramponi aninnovativeclinicalevaluationprotocolaftertotalanklearthroplastyapilotstudyusinginertialsensorsandbaropodometricplatforms
AT ariannaridolfi aninnovativeclinicalevaluationprotocolaftertotalanklearthroplastyapilotstudyusinginertialsensorsandbaropodometricplatforms
AT cesarefaldini aninnovativeclinicalevaluationprotocolaftertotalanklearthroplastyapilotstudyusinginertialsensorsandbaropodometricplatforms
AT lorenzobrognara aninnovativeclinicalevaluationprotocolaftertotalanklearthroplastyapilotstudyusinginertialsensorsandbaropodometricplatforms
AT antoniomazzotti innovativeclinicalevaluationprotocolaftertotalanklearthroplastyapilotstudyusinginertialsensorsandbaropodometricplatforms
AT albertoarceri innovativeclinicalevaluationprotocolaftertotalanklearthroplastyapilotstudyusinginertialsensorsandbaropodometricplatforms
AT pejmanabdi innovativeclinicalevaluationprotocolaftertotalanklearthroplastyapilotstudyusinginertialsensorsandbaropodometricplatforms
AT elenaartioli innovativeclinicalevaluationprotocolaftertotalanklearthroplastyapilotstudyusinginertialsensorsandbaropodometricplatforms
AT simoneottaviozielli innovativeclinicalevaluationprotocolaftertotalanklearthroplastyapilotstudyusinginertialsensorsandbaropodometricplatforms
AT lauralangone innovativeclinicalevaluationprotocolaftertotalanklearthroplastyapilotstudyusinginertialsensorsandbaropodometricplatforms
AT lauraramponi innovativeclinicalevaluationprotocolaftertotalanklearthroplastyapilotstudyusinginertialsensorsandbaropodometricplatforms
AT ariannaridolfi innovativeclinicalevaluationprotocolaftertotalanklearthroplastyapilotstudyusinginertialsensorsandbaropodometricplatforms
AT cesarefaldini innovativeclinicalevaluationprotocolaftertotalanklearthroplastyapilotstudyusinginertialsensorsandbaropodometricplatforms
AT lorenzobrognara innovativeclinicalevaluationprotocolaftertotalanklearthroplastyapilotstudyusinginertialsensorsandbaropodometricplatforms