Comparação do nível álgico no bloqueio do nervo alveolar inferior através de duas técnicas distintas
Abstract Introduction Blockade of the inferior alveolar nerve is among the most used and important anesthesia in dentistry, but there are no studies that compare the electronic anesthesia (Morpheus) and traditional manual anesthesia, using a syringe Carpule. Objective To evaluate and compare two a...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Universidade Estadual Paulista
|
Series: | Revista de Odontologia da UNESP |
Subjects: | |
Online Access: | http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1807-25772016005020101&lng=en&tlng=en |
_version_ | 1818546528944390144 |
---|---|
author | João Marcos Rodrigues de ARAGÃO Klinger de Souza AMORIM Rafael Soares da CUNHA Francisco Carlos GROPPO Liane Maciel de Almeida SOUZA |
author_facet | João Marcos Rodrigues de ARAGÃO Klinger de Souza AMORIM Rafael Soares da CUNHA Francisco Carlos GROPPO Liane Maciel de Almeida SOUZA |
author_sort | João Marcos Rodrigues de ARAGÃO |
collection | DOAJ |
description | Abstract Introduction Blockade of the inferior alveolar nerve is among the most used and important anesthesia in dentistry, but there are no studies that compare the electronic anesthesia (Morpheus) and traditional manual anesthesia, using a syringe Carpule. Objective To evaluate and compare two anesthesia systems with respect to pain sensitivity during and after anesthesia with lidocaine 2% associated with epinephrine 1: 100,000 in anesthetic techniques for inferior alveolar nerve. Material and method This clinical trial was performed in a randomized, crossover, double-blind, involving 30 volunteers, who required dental treatment and who underwent blockade of the lower alveolar nerve, using the syringe type Carpule in the first session and the gun controlled speed Morpheus, where it was held in two sessions, with an interval of at least two weeks between each session. At the end of each session was applied to Visual Analogue Scale (VAS) to assess pain sensitivity to injection. Result A comparison between the conventional methods revealed that induce showed higher values than the EVA Morpheus. The chi -square for expected equal proportions showed that the technique with Morpheus had a higher (p = 0.0062) preference than conventional. Conclusion Taken together, the data show that the technique employing the Morpheus was superior to conventional in 3 times. The implementation of anesthesia performed with Morpheus proved to be more comfortable, have greater acceptance and preference for volunteers. |
first_indexed | 2024-12-12T07:54:26Z |
format | Article |
id | doaj.art-90440dca8f7c4322aaf14010a132c9ec |
institution | Directory Open Access Journal |
issn | 1807-2577 |
language | English |
last_indexed | 2024-12-12T07:54:26Z |
publisher | Universidade Estadual Paulista |
record_format | Article |
series | Revista de Odontologia da UNESP |
spelling | doaj.art-90440dca8f7c4322aaf14010a132c9ec2022-12-22T00:32:21ZengUniversidade Estadual PaulistaRevista de Odontologia da UNESP1807-2577010.1590/1807-2577.04216S1807-25772016005020101Comparação do nível álgico no bloqueio do nervo alveolar inferior através de duas técnicas distintasJoão Marcos Rodrigues de ARAGÃOKlinger de Souza AMORIMRafael Soares da CUNHAFrancisco Carlos GROPPOLiane Maciel de Almeida SOUZAAbstract Introduction Blockade of the inferior alveolar nerve is among the most used and important anesthesia in dentistry, but there are no studies that compare the electronic anesthesia (Morpheus) and traditional manual anesthesia, using a syringe Carpule. Objective To evaluate and compare two anesthesia systems with respect to pain sensitivity during and after anesthesia with lidocaine 2% associated with epinephrine 1: 100,000 in anesthetic techniques for inferior alveolar nerve. Material and method This clinical trial was performed in a randomized, crossover, double-blind, involving 30 volunteers, who required dental treatment and who underwent blockade of the lower alveolar nerve, using the syringe type Carpule in the first session and the gun controlled speed Morpheus, where it was held in two sessions, with an interval of at least two weeks between each session. At the end of each session was applied to Visual Analogue Scale (VAS) to assess pain sensitivity to injection. Result A comparison between the conventional methods revealed that induce showed higher values than the EVA Morpheus. The chi -square for expected equal proportions showed that the technique with Morpheus had a higher (p = 0.0062) preference than conventional. Conclusion Taken together, the data show that the technique employing the Morpheus was superior to conventional in 3 times. The implementation of anesthesia performed with Morpheus proved to be more comfortable, have greater acceptance and preference for volunteers.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1807-25772016005020101&lng=en&tlng=enAnesthesiaacheinferior alveolar nerve |
spellingShingle | João Marcos Rodrigues de ARAGÃO Klinger de Souza AMORIM Rafael Soares da CUNHA Francisco Carlos GROPPO Liane Maciel de Almeida SOUZA Comparação do nível álgico no bloqueio do nervo alveolar inferior através de duas técnicas distintas Revista de Odontologia da UNESP Anesthesia ache inferior alveolar nerve |
title | Comparação do nível álgico no bloqueio do nervo alveolar inferior através de duas técnicas distintas |
title_full | Comparação do nível álgico no bloqueio do nervo alveolar inferior através de duas técnicas distintas |
title_fullStr | Comparação do nível álgico no bloqueio do nervo alveolar inferior através de duas técnicas distintas |
title_full_unstemmed | Comparação do nível álgico no bloqueio do nervo alveolar inferior através de duas técnicas distintas |
title_short | Comparação do nível álgico no bloqueio do nervo alveolar inferior através de duas técnicas distintas |
title_sort | comparacao do nivel algico no bloqueio do nervo alveolar inferior atraves de duas tecnicas distintas |
topic | Anesthesia ache inferior alveolar nerve |
url | http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1807-25772016005020101&lng=en&tlng=en |
work_keys_str_mv | AT joaomarcosrodriguesdearagao comparacaodonivelalgiconobloqueiodonervoalveolarinferioratravesdeduastecnicasdistintas AT klingerdesouzaamorim comparacaodonivelalgiconobloqueiodonervoalveolarinferioratravesdeduastecnicasdistintas AT rafaelsoaresdacunha comparacaodonivelalgiconobloqueiodonervoalveolarinferioratravesdeduastecnicasdistintas AT franciscocarlosgroppo comparacaodonivelalgiconobloqueiodonervoalveolarinferioratravesdeduastecnicasdistintas AT lianemacieldealmeidasouza comparacaodonivelalgiconobloqueiodonervoalveolarinferioratravesdeduastecnicasdistintas |