Heat Transfer Characteristics in a Large-Scale Bubble Column Operating in a Semi – Batch Mode

Time-averaged local heat transfer coefficient profiles were studied in a 0.45m bubble column using air-water system. The effect of the superficial gas velocity andaxial locations (Z/D) on the heat transfer coefficient and its radial (r/R) profiles wereinvestigated in bubble column. Significant diffe...

Full description

Bibliographic Details
Main Authors: Rahman Sh. Abdulmohsin, Balasim A. Abid
Format: Article
Language:English
Published: Unviversity of Technology- Iraq 2010-01-01
Series:Engineering and Technology Journal
Subjects:
Online Access:https://etj.uotechnology.edu.iq/article_26979_b0f4870b875ccd7cd888c8e45ab1a6e5.pdf
Description
Summary:Time-averaged local heat transfer coefficient profiles were studied in a 0.45m bubble column using air-water system. The effect of the superficial gas velocity andaxial locations (Z/D) on the heat transfer coefficient and its radial (r/R) profiles wereinvestigated in bubble column. Significant differences were observed between heattransfer coefficients in the axial directions viz. in the bulk flow region (Z/D=4.8)higher than in the distributor region (Z/D=0.28) by 14% -22% for increasing thesuperficial gas velocity from 0.05-0.45 m/s. The heat transfer coefficients increasewith superficial gas velocities and the values in the center of the column were 9–13%greater than those near the wall region .The characteristics of bulk flow region arelarge variation in radial direction and little in axial direction for the values of heattransfer coefficients.
ISSN:1681-6900
2412-0758