Fire Behavior of Electrical Installations in Buildings

Electrical installations are a significant component of fire load inside a building, although they are often neglected in the overall fire safety analysis and are not subjected to any kind of fire safety evaluation of a building. A typical electrical installation unconnected to the mains was experim...

Full description

Bibliographic Details
Main Authors: Jadwiga Fangrat, Katarzyna Kaczorek-Chrobak, Bartłomiej K. Papis
Format: Article
Language:English
Published: MDPI AG 2020-12-01
Series:Energies
Subjects:
Online Access:https://www.mdpi.com/1996-1073/13/23/6433
_version_ 1811153761109803008
author Jadwiga Fangrat
Katarzyna Kaczorek-Chrobak
Bartłomiej K. Papis
author_facet Jadwiga Fangrat
Katarzyna Kaczorek-Chrobak
Bartłomiej K. Papis
author_sort Jadwiga Fangrat
collection DOAJ
description Electrical installations are a significant component of fire load inside a building, although they are often neglected in the overall fire safety analysis and are not subjected to any kind of fire safety evaluation of a building. A typical electrical installation unconnected to the mains was experimentally studied using a single burning item (SBI) test apparatus, fixed to two types of popular non-combustible or combustible (wooden-based) backgrounds simulating a typical building internal wall or ceiling. The semi-real scale test showed that poly(vinyl chloride) (PVC) cable, commonly used in installations in buildings in Europe and used in SBI tests, showed high fire properties related to heat release, smoke production and flame spread to other interior elements. The results of the electrical circuit connected to the main measurements carried out showed a significant impact of the heating effect towards the uncovered surface socket, causing the possibility of easy ignition inside the installation. In conclusion, it was found that even a relatively simple and short section of electrical installation resulted in a significant increase in the heat release rate and smoke generation parameters, obtained during the SBI tests, and as a consequence a reduction of one or two reaction to fire euroclasses of construction materials for internal walls.
first_indexed 2024-03-10T14:18:35Z
format Article
id doaj.art-90a70050cee44e7db0074c798715e839
institution Directory Open Access Journal
issn 1996-1073
language English
last_indexed 2024-03-10T14:18:35Z
publishDate 2020-12-01
publisher MDPI AG
record_format Article
series Energies
spelling doaj.art-90a70050cee44e7db0074c798715e8392023-11-20T23:33:51ZengMDPI AGEnergies1996-10732020-12-011323643310.3390/en13236433Fire Behavior of Electrical Installations in BuildingsJadwiga Fangrat0Katarzyna Kaczorek-Chrobak1Bartłomiej K. Papis2Instytut Techniki Budowlanej, Filtrowa 1, 00-611 Warszawa, PolandInstytut Techniki Budowlanej, Filtrowa 1, 00-611 Warszawa, PolandInstytut Techniki Budowlanej, Filtrowa 1, 00-611 Warszawa, PolandElectrical installations are a significant component of fire load inside a building, although they are often neglected in the overall fire safety analysis and are not subjected to any kind of fire safety evaluation of a building. A typical electrical installation unconnected to the mains was experimentally studied using a single burning item (SBI) test apparatus, fixed to two types of popular non-combustible or combustible (wooden-based) backgrounds simulating a typical building internal wall or ceiling. The semi-real scale test showed that poly(vinyl chloride) (PVC) cable, commonly used in installations in buildings in Europe and used in SBI tests, showed high fire properties related to heat release, smoke production and flame spread to other interior elements. The results of the electrical circuit connected to the main measurements carried out showed a significant impact of the heating effect towards the uncovered surface socket, causing the possibility of easy ignition inside the installation. In conclusion, it was found that even a relatively simple and short section of electrical installation resulted in a significant increase in the heat release rate and smoke generation parameters, obtained during the SBI tests, and as a consequence a reduction of one or two reaction to fire euroclasses of construction materials for internal walls.https://www.mdpi.com/1996-1073/13/23/6433fire behavior of electrical installationheat release rate of electrical installationsmoke release rate of electrical installationsSBI testfire properties of cables
spellingShingle Jadwiga Fangrat
Katarzyna Kaczorek-Chrobak
Bartłomiej K. Papis
Fire Behavior of Electrical Installations in Buildings
Energies
fire behavior of electrical installation
heat release rate of electrical installation
smoke release rate of electrical installations
SBI test
fire properties of cables
title Fire Behavior of Electrical Installations in Buildings
title_full Fire Behavior of Electrical Installations in Buildings
title_fullStr Fire Behavior of Electrical Installations in Buildings
title_full_unstemmed Fire Behavior of Electrical Installations in Buildings
title_short Fire Behavior of Electrical Installations in Buildings
title_sort fire behavior of electrical installations in buildings
topic fire behavior of electrical installation
heat release rate of electrical installation
smoke release rate of electrical installations
SBI test
fire properties of cables
url https://www.mdpi.com/1996-1073/13/23/6433
work_keys_str_mv AT jadwigafangrat firebehaviorofelectricalinstallationsinbuildings
AT katarzynakaczorekchrobak firebehaviorofelectricalinstallationsinbuildings
AT bartłomiejkpapis firebehaviorofelectricalinstallationsinbuildings