Design of automatic frequency-conversion control system of fireproof and extinguishing by even air pressure

In view of problem of big power consumption, low degree of automation, low accuracy and real-time performance existed in traditional and artificial control method of fireproof and extinguishing by even air pressure, an automatic frequency-conversion control system of fireproof and extinguishing by e...

Full description

Bibliographic Details
Main Authors: WU Fusheng, HUANG Linhua, HE Min, JIANG Dezhi
Format: Article
Language:zho
Published: Editorial Department of Industry and Mine Automation 2014-05-01
Series:Gong-kuang zidonghua
Subjects:
Online Access:http://www.gkzdh.cn/article/doi/10.13272/j.issn.1671-251x.2014.05.021
_version_ 1797868713658023936
author WU Fusheng
HUANG Linhua
HE Min
JIANG Dezhi
author_facet WU Fusheng
HUANG Linhua
HE Min
JIANG Dezhi
author_sort WU Fusheng
collection DOAJ
description In view of problem of big power consumption, low degree of automation, low accuracy and real-time performance existed in traditional and artificial control method of fireproof and extinguishing by even air pressure, an automatic frequency-conversion control system of fireproof and extinguishing by even air pressure was designed, and composition, operation mode, control method and logic implementation process of the system were introduced. The system adopts theory of local dynamic air pressure balance of multilayer goaf flow field, uses method of automatic frequency-conversion to control local ventilator to change pressure of working face according to differential pressure of working face and upper adjacent goaf, so as to reach the purpose of pressure equalizing of working face and ambient, which realizes automatic control of fireproof and extinguishing by even air pressure of interconnected mining working faces of multilayer goaf.
first_indexed 2024-04-10T00:00:12Z
format Article
id doaj.art-90c6b6ea5f05452ca0b0ee87883778f6
institution Directory Open Access Journal
issn 1671-251X
language zho
last_indexed 2024-04-10T00:00:12Z
publishDate 2014-05-01
publisher Editorial Department of Industry and Mine Automation
record_format Article
series Gong-kuang zidonghua
spelling doaj.art-90c6b6ea5f05452ca0b0ee87883778f62023-03-17T01:51:52ZzhoEditorial Department of Industry and Mine AutomationGong-kuang zidonghua1671-251X2014-05-01405848710.13272/j.issn.1671-251x.2014.05.021Design of automatic frequency-conversion control system of fireproof and extinguishing by even air pressureWU FushengHUANG Linhua0HE Min1JIANG Dezhi2CCTEG Changzhou Research Institute, Changzhou 213015, ChinaCCTEG Changzhou Research Institute, Changzhou 213015, ChinaCCTEG Changzhou Research Institute, Changzhou 213015, ChinaIn view of problem of big power consumption, low degree of automation, low accuracy and real-time performance existed in traditional and artificial control method of fireproof and extinguishing by even air pressure, an automatic frequency-conversion control system of fireproof and extinguishing by even air pressure was designed, and composition, operation mode, control method and logic implementation process of the system were introduced. The system adopts theory of local dynamic air pressure balance of multilayer goaf flow field, uses method of automatic frequency-conversion to control local ventilator to change pressure of working face according to differential pressure of working face and upper adjacent goaf, so as to reach the purpose of pressure equalizing of working face and ambient, which realizes automatic control of fireproof and extinguishing by even air pressure of interconnected mining working faces of multilayer goaf.http://www.gkzdh.cn/article/doi/10.13272/j.issn.1671-251x.2014.05.021fireproof and extinguishing by even air pressureautomatic frequency-conversion controldynamic air pressure balance
spellingShingle WU Fusheng
HUANG Linhua
HE Min
JIANG Dezhi
Design of automatic frequency-conversion control system of fireproof and extinguishing by even air pressure
Gong-kuang zidonghua
fireproof and extinguishing by even air pressure
automatic frequency-conversion control
dynamic air pressure balance
title Design of automatic frequency-conversion control system of fireproof and extinguishing by even air pressure
title_full Design of automatic frequency-conversion control system of fireproof and extinguishing by even air pressure
title_fullStr Design of automatic frequency-conversion control system of fireproof and extinguishing by even air pressure
title_full_unstemmed Design of automatic frequency-conversion control system of fireproof and extinguishing by even air pressure
title_short Design of automatic frequency-conversion control system of fireproof and extinguishing by even air pressure
title_sort design of automatic frequency conversion control system of fireproof and extinguishing by even air pressure
topic fireproof and extinguishing by even air pressure
automatic frequency-conversion control
dynamic air pressure balance
url http://www.gkzdh.cn/article/doi/10.13272/j.issn.1671-251x.2014.05.021
work_keys_str_mv AT wufusheng designofautomaticfrequencyconversioncontrolsystemoffireproofandextinguishingbyevenairpressure
AT huanglinhua designofautomaticfrequencyconversioncontrolsystemoffireproofandextinguishingbyevenairpressure
AT hemin designofautomaticfrequencyconversioncontrolsystemoffireproofandextinguishingbyevenairpressure
AT jiangdezhi designofautomaticfrequencyconversioncontrolsystemoffireproofandextinguishingbyevenairpressure