Aromatic Fingerprints: VOC Analysis with E-Nose and GC-MS for Rapid Detection of Adulteration in Sesame Oil

Food quality assurance is an important field that directly affects public health. The organoleptic aroma of food is of crucial significance to evaluate and confirm food quality and origin. The volatile organic compound (VOC) emissions (detectable aroma) from foods are unique and provide a basis to p...

Full description

Bibliographic Details
Main Authors: Nadia Sadat Aghili, Mansour Rasekh, Hamed Karami, Omid Edriss, Alphus Dan Wilson, Jose Ramos
Format: Article
Language:English
Published: MDPI AG 2023-07-01
Series:Sensors
Subjects:
Online Access:https://www.mdpi.com/1424-8220/23/14/6294
_version_ 1827731837136404480
author Nadia Sadat Aghili
Mansour Rasekh
Hamed Karami
Omid Edriss
Alphus Dan Wilson
Jose Ramos
author_facet Nadia Sadat Aghili
Mansour Rasekh
Hamed Karami
Omid Edriss
Alphus Dan Wilson
Jose Ramos
author_sort Nadia Sadat Aghili
collection DOAJ
description Food quality assurance is an important field that directly affects public health. The organoleptic aroma of food is of crucial significance to evaluate and confirm food quality and origin. The volatile organic compound (VOC) emissions (detectable aroma) from foods are unique and provide a basis to predict and evaluate food quality. Soybean and corn oils were added to sesame oil (to simulate adulteration) at four different mixture percentages (25–100%) and then chemically analyzed using an experimental 9-sensor metal oxide semiconducting (MOS) electronic nose (e-nose) and gas chromatography–mass spectroscopy (GC-MS) for comparisons in detecting unadulterated sesame oil controls. GC-MS analysis revealed eleven major VOC components identified within 82–91% of oil samples. Principle component analysis (PCA) and linear detection analysis (LDA) were employed to visualize different levels of adulteration detected by the e-nose. Artificial neural networks (ANNs) and support vector machines (SVMs) were also used for statistical modeling. The sensitivity and specificity obtained for SVM were 0.987 and 0.977, respectively, while these values for the ANN method were 0.949 and 0.953, respectively. E-nose-based technology is a quick and effective method for the detection of sesame oil adulteration due to its simplicity (ease of application), rapid analysis, and accuracy. GC-MS data provided corroborative chemical evidence to show differences in volatile emissions from virgin and adulterated sesame oil samples and the precise VOCs explaining differences in e-nose signature patterns derived from each sample type.
first_indexed 2024-03-11T00:41:11Z
format Article
id doaj.art-921df49d33224008bd7ddb09ee2d9b14
institution Directory Open Access Journal
issn 1424-8220
language English
last_indexed 2024-03-11T00:41:11Z
publishDate 2023-07-01
publisher MDPI AG
record_format Article
series Sensors
spelling doaj.art-921df49d33224008bd7ddb09ee2d9b142023-11-18T21:15:43ZengMDPI AGSensors1424-82202023-07-012314629410.3390/s23146294Aromatic Fingerprints: VOC Analysis with E-Nose and GC-MS for Rapid Detection of Adulteration in Sesame OilNadia Sadat Aghili0Mansour Rasekh1Hamed Karami2Omid Edriss3Alphus Dan Wilson4Jose Ramos5Department of Biosystems Engineering, University of Mohaghegh Ardabili, Ardabil 56199-11367, IranDepartment of Biosystems Engineering, University of Mohaghegh Ardabili, Ardabil 56199-11367, IranDepartment of Petroleum Engineering, Knowledge University, Erbil 44001, IraqDepartment of Computer, Rafsanjan Branch, Islamic Azad University, Rafsanjan 77181-84483, IranSouthern Hardwoods Laboratory, Pathology Department, Center for Forest Health & Disturbance, Forest Genetics & Ecosystems Biology, Southern Research Station, USDA Forest Service, 432 Stoneville Road, Stoneville, MS 38776-0227, USACollege of Computing and Engineering, Nova Southeastern University (NSU), 3301 College Avenue, Fort Lauderdale, FL 33314-7796, USAFood quality assurance is an important field that directly affects public health. The organoleptic aroma of food is of crucial significance to evaluate and confirm food quality and origin. The volatile organic compound (VOC) emissions (detectable aroma) from foods are unique and provide a basis to predict and evaluate food quality. Soybean and corn oils were added to sesame oil (to simulate adulteration) at four different mixture percentages (25–100%) and then chemically analyzed using an experimental 9-sensor metal oxide semiconducting (MOS) electronic nose (e-nose) and gas chromatography–mass spectroscopy (GC-MS) for comparisons in detecting unadulterated sesame oil controls. GC-MS analysis revealed eleven major VOC components identified within 82–91% of oil samples. Principle component analysis (PCA) and linear detection analysis (LDA) were employed to visualize different levels of adulteration detected by the e-nose. Artificial neural networks (ANNs) and support vector machines (SVMs) were also used for statistical modeling. The sensitivity and specificity obtained for SVM were 0.987 and 0.977, respectively, while these values for the ANN method were 0.949 and 0.953, respectively. E-nose-based technology is a quick and effective method for the detection of sesame oil adulteration due to its simplicity (ease of application), rapid analysis, and accuracy. GC-MS data provided corroborative chemical evidence to show differences in volatile emissions from virgin and adulterated sesame oil samples and the precise VOCs explaining differences in e-nose signature patterns derived from each sample type.https://www.mdpi.com/1424-8220/23/14/6294oil adulteration detectionedible oilschemometricsgas sensorsmachine learningmass spectroscopy
spellingShingle Nadia Sadat Aghili
Mansour Rasekh
Hamed Karami
Omid Edriss
Alphus Dan Wilson
Jose Ramos
Aromatic Fingerprints: VOC Analysis with E-Nose and GC-MS for Rapid Detection of Adulteration in Sesame Oil
Sensors
oil adulteration detection
edible oils
chemometrics
gas sensors
machine learning
mass spectroscopy
title Aromatic Fingerprints: VOC Analysis with E-Nose and GC-MS for Rapid Detection of Adulteration in Sesame Oil
title_full Aromatic Fingerprints: VOC Analysis with E-Nose and GC-MS for Rapid Detection of Adulteration in Sesame Oil
title_fullStr Aromatic Fingerprints: VOC Analysis with E-Nose and GC-MS for Rapid Detection of Adulteration in Sesame Oil
title_full_unstemmed Aromatic Fingerprints: VOC Analysis with E-Nose and GC-MS for Rapid Detection of Adulteration in Sesame Oil
title_short Aromatic Fingerprints: VOC Analysis with E-Nose and GC-MS for Rapid Detection of Adulteration in Sesame Oil
title_sort aromatic fingerprints voc analysis with e nose and gc ms for rapid detection of adulteration in sesame oil
topic oil adulteration detection
edible oils
chemometrics
gas sensors
machine learning
mass spectroscopy
url https://www.mdpi.com/1424-8220/23/14/6294
work_keys_str_mv AT nadiasadataghili aromaticfingerprintsvocanalysiswithenoseandgcmsforrapiddetectionofadulterationinsesameoil
AT mansourrasekh aromaticfingerprintsvocanalysiswithenoseandgcmsforrapiddetectionofadulterationinsesameoil
AT hamedkarami aromaticfingerprintsvocanalysiswithenoseandgcmsforrapiddetectionofadulterationinsesameoil
AT omidedriss aromaticfingerprintsvocanalysiswithenoseandgcmsforrapiddetectionofadulterationinsesameoil
AT alphusdanwilson aromaticfingerprintsvocanalysiswithenoseandgcmsforrapiddetectionofadulterationinsesameoil
AT joseramos aromaticfingerprintsvocanalysiswithenoseandgcmsforrapiddetectionofadulterationinsesameoil