Photoacoustic tomography system based on Diode Laser to Imaging of some types of materials

Photoacoustic tomography imaging research has been conducted to distinguish several types of materials. The photoacoustic tomography imaging system used in this study uses a diode laser as a source of radiation and a condenser microphone as a detection tool. The sample is a combination of two types...

Full description

Bibliographic Details
Main Authors: Mitrayana Mitrayana, Dara Cynthia Nur Cahyani, Mirza Satriawan
Format: Article
Language:English
Published: Universitas Sebelas Maret 2020-09-01
Series:Journal of Physics: Theories and Applications
Subjects:
Online Access:https://jurnal.uns.ac.id/jphystheor-appl/article/view/42547
_version_ 1811327439582789632
author Mitrayana Mitrayana
Dara Cynthia Nur Cahyani
Mirza Satriawan
author_facet Mitrayana Mitrayana
Dara Cynthia Nur Cahyani
Mirza Satriawan
author_sort Mitrayana Mitrayana
collection DOAJ
description Photoacoustic tomography imaging research has been conducted to distinguish several types of materials. The photoacoustic tomography imaging system used in this study uses a diode laser as a source of radiation and a condenser microphone as a detection tool. The sample is a combination of two types of materials, namely plasticine + iron wire, plasticine + cardboard, plasticine + mica plastic, and mica plastic + cardboard. Optimum setting of laser modulation frequency and duty cycle system to distinguish images from plasticine samples + iron wire and plasticine + cardboard, i.e., 19 kHz and 50%, while to recognize images from plasticine samples + mica plastic and mica plastic + cardboard, which is 19.5 kHz and 50%. The photoacoustic tomography image system used can detect and image the sample clearly, the striking color difference between one material, and another shows the difference in sound intensity.
first_indexed 2024-04-13T15:08:02Z
format Article
id doaj.art-9242dab3db714f738f1b99da18444d23
institution Directory Open Access Journal
issn 2549-7316
2549-7324
language English
last_indexed 2024-04-13T15:08:02Z
publishDate 2020-09-01
publisher Universitas Sebelas Maret
record_format Article
series Journal of Physics: Theories and Applications
spelling doaj.art-9242dab3db714f738f1b99da18444d232022-12-22T02:42:07ZengUniversitas Sebelas MaretJournal of Physics: Theories and Applications2549-73162549-73242020-09-0142707810.20961/jphystheor-appl.v4i2.4254729078Photoacoustic tomography system based on Diode Laser to Imaging of some types of materialsMitrayana Mitrayana0Dara Cynthia Nur Cahyani1Mirza Satriawan2Physics Department, Universitas Gadjah MadaPhysics Department, Universitas Gadjah MadaPhysics Department, Universitas Gadjah MadaPhotoacoustic tomography imaging research has been conducted to distinguish several types of materials. The photoacoustic tomography imaging system used in this study uses a diode laser as a source of radiation and a condenser microphone as a detection tool. The sample is a combination of two types of materials, namely plasticine + iron wire, plasticine + cardboard, plasticine + mica plastic, and mica plastic + cardboard. Optimum setting of laser modulation frequency and duty cycle system to distinguish images from plasticine samples + iron wire and plasticine + cardboard, i.e., 19 kHz and 50%, while to recognize images from plasticine samples + mica plastic and mica plastic + cardboard, which is 19.5 kHz and 50%. The photoacoustic tomography image system used can detect and image the sample clearly, the striking color difference between one material, and another shows the difference in sound intensity.https://jurnal.uns.ac.id/jphystheor-appl/article/view/42547photoacoustic tomography, diode laser, condenser microphone, duty cycle.
spellingShingle Mitrayana Mitrayana
Dara Cynthia Nur Cahyani
Mirza Satriawan
Photoacoustic tomography system based on Diode Laser to Imaging of some types of materials
Journal of Physics: Theories and Applications
photoacoustic tomography, diode laser, condenser microphone, duty cycle.
title Photoacoustic tomography system based on Diode Laser to Imaging of some types of materials
title_full Photoacoustic tomography system based on Diode Laser to Imaging of some types of materials
title_fullStr Photoacoustic tomography system based on Diode Laser to Imaging of some types of materials
title_full_unstemmed Photoacoustic tomography system based on Diode Laser to Imaging of some types of materials
title_short Photoacoustic tomography system based on Diode Laser to Imaging of some types of materials
title_sort photoacoustic tomography system based on diode laser to imaging of some types of materials
topic photoacoustic tomography, diode laser, condenser microphone, duty cycle.
url https://jurnal.uns.ac.id/jphystheor-appl/article/view/42547
work_keys_str_mv AT mitrayanamitrayana photoacoustictomographysystembasedondiodelasertoimagingofsometypesofmaterials
AT daracynthianurcahyani photoacoustictomographysystembasedondiodelasertoimagingofsometypesofmaterials
AT mirzasatriawan photoacoustictomographysystembasedondiodelasertoimagingofsometypesofmaterials