Monte carlo calculation of beam quality and phantom scatter corrections for lithium formate electron paramagnetic resonance dosimeter for high-energy brachytherapy dosimetry

Purpose: To investigate beam quality correction, KQQ0 (r) and phantom scatter correction, Kphan (r) for lithium formate dosimeter as a function of distance r along the transverse axis of the high-energy brachytherapy sources 60Co, 137Cs, 192Ir and 169Yb using the Monte Carlo-based EGSnrc code system...

Full description

Bibliographic Details
Main Authors: Subhalaxmi Mishra, T Palani Selvam
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2017-01-01
Series:Journal of Medical Physics
Subjects:
Online Access:http://www.jmp.org.in/article.asp?issn=0971-6203;year=2017;volume=42;issue=2;spage=72;epage=79;aulast=Mishra
_version_ 1828530267323629568
author Subhalaxmi Mishra
T Palani Selvam
author_facet Subhalaxmi Mishra
T Palani Selvam
author_sort Subhalaxmi Mishra
collection DOAJ
description Purpose: To investigate beam quality correction, KQQ0 (r) and phantom scatter correction, Kphan (r) for lithium formate dosimeter as a function of distance r along the transverse axis of the high-energy brachytherapy sources 60Co, 137Cs, 192Ir and 169Yb using the Monte Carlo-based EGSnrc code system. Materials and Methods: The brachytherapy sources investigated in this study are BEBIG High Dose Rate (HDR) 60Co (model Co0.A86), 137Cs (model RTR), HDR 192Ir (model Microselectron) and HDR 169Yb (model 4140). The solid phantom materials investigated are PMMA, polystyrene, solid water, virtual water, plastic water, RW1, RW3, A150 and WE210. Result:KQQ0 (r) is about unity and distance independent for 60Co, 137Cs and 192Ir brachytherapy sources, whereas for the 169Yb source, KQQ0 (r) increases gradually to about 4 % larger than unity at a distance of 15 cm along the transverse axis of the source. For 60Co source, phantoms such as polystyrene, plastic water, solid water, virtual water, RW1, RW3 and WE210 are water-equivalent but PMMA and A150 phantoms show distance-dependent Kphan (r) values. For 137Cs and 192Ir sources, phantoms such as solid water, virtual water, RW1, RW3 and WE210 are water-equivalent. However, phantoms such as PMMA, plastic water, polystyrene and A150 showed distance-dependent Kphan (r) values, for these sources. For 169Yb source, all the investigated phantoms show distance-dependent Kphan (r) values. Conclusion: KQQ0 (r) is about unity and distance independent for 60Co, 137Cs and 192Ir brachytherapy sources. Phantoms such as solid water, virtual water, RW1, RW3 and WE210 are water-equivalent for 60Co, 137Cs and 192Ir brachytherapy sources. For 169Yb source, all the investigated phantoms show distance-dependent Kphan (r) values.
first_indexed 2024-12-11T22:20:48Z
format Article
id doaj.art-92638627dcf2465da93fa767aa8219f2
institution Directory Open Access Journal
issn 0971-6203
1998-3913
language English
last_indexed 2024-12-11T22:20:48Z
publishDate 2017-01-01
publisher Wolters Kluwer Medknow Publications
record_format Article
series Journal of Medical Physics
spelling doaj.art-92638627dcf2465da93fa767aa8219f22022-12-22T00:48:27ZengWolters Kluwer Medknow PublicationsJournal of Medical Physics0971-62031998-39132017-01-01422727910.4103/jmp.JMP_95_16Monte carlo calculation of beam quality and phantom scatter corrections for lithium formate electron paramagnetic resonance dosimeter for high-energy brachytherapy dosimetrySubhalaxmi MishraT Palani SelvamPurpose: To investigate beam quality correction, KQQ0 (r) and phantom scatter correction, Kphan (r) for lithium formate dosimeter as a function of distance r along the transverse axis of the high-energy brachytherapy sources 60Co, 137Cs, 192Ir and 169Yb using the Monte Carlo-based EGSnrc code system. Materials and Methods: The brachytherapy sources investigated in this study are BEBIG High Dose Rate (HDR) 60Co (model Co0.A86), 137Cs (model RTR), HDR 192Ir (model Microselectron) and HDR 169Yb (model 4140). The solid phantom materials investigated are PMMA, polystyrene, solid water, virtual water, plastic water, RW1, RW3, A150 and WE210. Result:KQQ0 (r) is about unity and distance independent for 60Co, 137Cs and 192Ir brachytherapy sources, whereas for the 169Yb source, KQQ0 (r) increases gradually to about 4 % larger than unity at a distance of 15 cm along the transverse axis of the source. For 60Co source, phantoms such as polystyrene, plastic water, solid water, virtual water, RW1, RW3 and WE210 are water-equivalent but PMMA and A150 phantoms show distance-dependent Kphan (r) values. For 137Cs and 192Ir sources, phantoms such as solid water, virtual water, RW1, RW3 and WE210 are water-equivalent. However, phantoms such as PMMA, plastic water, polystyrene and A150 showed distance-dependent Kphan (r) values, for these sources. For 169Yb source, all the investigated phantoms show distance-dependent Kphan (r) values. Conclusion: KQQ0 (r) is about unity and distance independent for 60Co, 137Cs and 192Ir brachytherapy sources. Phantoms such as solid water, virtual water, RW1, RW3 and WE210 are water-equivalent for 60Co, 137Cs and 192Ir brachytherapy sources. For 169Yb source, all the investigated phantoms show distance-dependent Kphan (r) values.http://www.jmp.org.in/article.asp?issn=0971-6203;year=2017;volume=42;issue=2;spage=72;epage=79;aulast=MishraBeam quality correctionbrachytherapylithium formateMonte Carlophantom scatter correction
spellingShingle Subhalaxmi Mishra
T Palani Selvam
Monte carlo calculation of beam quality and phantom scatter corrections for lithium formate electron paramagnetic resonance dosimeter for high-energy brachytherapy dosimetry
Journal of Medical Physics
Beam quality correction
brachytherapy
lithium formate
Monte Carlo
phantom scatter correction
title Monte carlo calculation of beam quality and phantom scatter corrections for lithium formate electron paramagnetic resonance dosimeter for high-energy brachytherapy dosimetry
title_full Monte carlo calculation of beam quality and phantom scatter corrections for lithium formate electron paramagnetic resonance dosimeter for high-energy brachytherapy dosimetry
title_fullStr Monte carlo calculation of beam quality and phantom scatter corrections for lithium formate electron paramagnetic resonance dosimeter for high-energy brachytherapy dosimetry
title_full_unstemmed Monte carlo calculation of beam quality and phantom scatter corrections for lithium formate electron paramagnetic resonance dosimeter for high-energy brachytherapy dosimetry
title_short Monte carlo calculation of beam quality and phantom scatter corrections for lithium formate electron paramagnetic resonance dosimeter for high-energy brachytherapy dosimetry
title_sort monte carlo calculation of beam quality and phantom scatter corrections for lithium formate electron paramagnetic resonance dosimeter for high energy brachytherapy dosimetry
topic Beam quality correction
brachytherapy
lithium formate
Monte Carlo
phantom scatter correction
url http://www.jmp.org.in/article.asp?issn=0971-6203;year=2017;volume=42;issue=2;spage=72;epage=79;aulast=Mishra
work_keys_str_mv AT subhalaxmimishra montecarlocalculationofbeamqualityandphantomscattercorrectionsforlithiumformateelectronparamagneticresonancedosimeterforhighenergybrachytherapydosimetry
AT tpalaniselvam montecarlocalculationofbeamqualityandphantomscattercorrectionsforlithiumformateelectronparamagneticresonancedosimeterforhighenergybrachytherapydosimetry