The effects of stochastic resonance electrical stimulation and neoprene sleeve on knee proprioception

<p>Abstract</p> <p>Background</p> <p>A variety of knee injuries and pathologies may cause a deficit in knee proprioception which may increase the risk of reinjury or the progression of disease. Stochastic resonance stimulation is a new therapy which has potential benefi...

Full description

Bibliographic Details
Main Authors: Olcott Chris W, Blackburn J Troy, Collins Amber T, Dirschl Douglas R, Weinhold Paul S
Format: Article
Language:English
Published: BMC 2009-02-01
Series:Journal of Orthopaedic Surgery and Research
Online Access:http://www.josr-online.com/content/4/1/3
_version_ 1818012336716251136
author Olcott Chris W
Blackburn J Troy
Collins Amber T
Dirschl Douglas R
Weinhold Paul S
author_facet Olcott Chris W
Blackburn J Troy
Collins Amber T
Dirschl Douglas R
Weinhold Paul S
author_sort Olcott Chris W
collection DOAJ
description <p>Abstract</p> <p>Background</p> <p>A variety of knee injuries and pathologies may cause a deficit in knee proprioception which may increase the risk of reinjury or the progression of disease. Stochastic resonance stimulation is a new therapy which has potential benefits for improving proprioceptive function. The objective of this study was to determine if stochastic resonance (SR) stimulation applied with a neoprene sleeve could improve knee proprioception relative to a no-stimulation/no-sleeve condition (control) or a sleeve alone condition in the normal, healthy knee. We hypothesized that SR stimulation when applied with a sleeve would enhance proprioception relative to the control and sleeve alone conditions.</p> <p>Methods</p> <p>Using a cross-over within subject design, twenty-four healthy subjects were tested under four combinations of conditions: electrical stimulation/sleeve, no stimulation/sleeve, no stimulation/no sleeve, and stimulation/no sleeve. Joint position sense (proprioception) was measured as the absolute mean difference between a target knee joint angle and the knee angle reproduced by the subject. Testing was conducted during both partial-weight bearing (PWB) and non-weight bearing (NWB) tasks. Differences in joint position sense between the conditions were evaluated by repeated-measures analysis of variance testing.</p> <p>Results</p> <p>Joint position sense error during the stimulation/sleeve condition (2.48° ± 1.32°) was found to be more accurate (P < 0.05) relative to the control condition (3.35° ± 1.63°) in the PWB task. No difference in joint position sense error was found between stimulation/sleeve and sleeve alone conditions for the PWB task. Joint position sense error was not found to differ between any of the conditions for the NWB task.</p> <p>Conclusion</p> <p>These results suggest that SR electrical stimulation when combined with a neoprene sleeve is an effective modality for enhancement of joint proprioception in the PWB knee. We believe these results suggest the need for further study of the potential of SR stimulation to correct proprioceptive deficits in a clinical population with knee injury/pathology or in subjects at risk of injury because of a proprioceptive deficit.</p>
first_indexed 2024-04-14T06:19:57Z
format Article
id doaj.art-92c2bf792bac40f4aab531bfa8213383
institution Directory Open Access Journal
issn 1749-799X
language English
last_indexed 2024-04-14T06:19:57Z
publishDate 2009-02-01
publisher BMC
record_format Article
series Journal of Orthopaedic Surgery and Research
spelling doaj.art-92c2bf792bac40f4aab531bfa82133832022-12-22T02:08:05ZengBMCJournal of Orthopaedic Surgery and Research1749-799X2009-02-0141310.1186/1749-799X-4-3The effects of stochastic resonance electrical stimulation and neoprene sleeve on knee proprioceptionOlcott Chris WBlackburn J TroyCollins Amber TDirschl Douglas RWeinhold Paul S<p>Abstract</p> <p>Background</p> <p>A variety of knee injuries and pathologies may cause a deficit in knee proprioception which may increase the risk of reinjury or the progression of disease. Stochastic resonance stimulation is a new therapy which has potential benefits for improving proprioceptive function. The objective of this study was to determine if stochastic resonance (SR) stimulation applied with a neoprene sleeve could improve knee proprioception relative to a no-stimulation/no-sleeve condition (control) or a sleeve alone condition in the normal, healthy knee. We hypothesized that SR stimulation when applied with a sleeve would enhance proprioception relative to the control and sleeve alone conditions.</p> <p>Methods</p> <p>Using a cross-over within subject design, twenty-four healthy subjects were tested under four combinations of conditions: electrical stimulation/sleeve, no stimulation/sleeve, no stimulation/no sleeve, and stimulation/no sleeve. Joint position sense (proprioception) was measured as the absolute mean difference between a target knee joint angle and the knee angle reproduced by the subject. Testing was conducted during both partial-weight bearing (PWB) and non-weight bearing (NWB) tasks. Differences in joint position sense between the conditions were evaluated by repeated-measures analysis of variance testing.</p> <p>Results</p> <p>Joint position sense error during the stimulation/sleeve condition (2.48° ± 1.32°) was found to be more accurate (P < 0.05) relative to the control condition (3.35° ± 1.63°) in the PWB task. No difference in joint position sense error was found between stimulation/sleeve and sleeve alone conditions for the PWB task. Joint position sense error was not found to differ between any of the conditions for the NWB task.</p> <p>Conclusion</p> <p>These results suggest that SR electrical stimulation when combined with a neoprene sleeve is an effective modality for enhancement of joint proprioception in the PWB knee. We believe these results suggest the need for further study of the potential of SR stimulation to correct proprioceptive deficits in a clinical population with knee injury/pathology or in subjects at risk of injury because of a proprioceptive deficit.</p>http://www.josr-online.com/content/4/1/3
spellingShingle Olcott Chris W
Blackburn J Troy
Collins Amber T
Dirschl Douglas R
Weinhold Paul S
The effects of stochastic resonance electrical stimulation and neoprene sleeve on knee proprioception
Journal of Orthopaedic Surgery and Research
title The effects of stochastic resonance electrical stimulation and neoprene sleeve on knee proprioception
title_full The effects of stochastic resonance electrical stimulation and neoprene sleeve on knee proprioception
title_fullStr The effects of stochastic resonance electrical stimulation and neoprene sleeve on knee proprioception
title_full_unstemmed The effects of stochastic resonance electrical stimulation and neoprene sleeve on knee proprioception
title_short The effects of stochastic resonance electrical stimulation and neoprene sleeve on knee proprioception
title_sort effects of stochastic resonance electrical stimulation and neoprene sleeve on knee proprioception
url http://www.josr-online.com/content/4/1/3
work_keys_str_mv AT olcottchrisw theeffectsofstochasticresonanceelectricalstimulationandneoprenesleeveonkneeproprioception
AT blackburnjtroy theeffectsofstochasticresonanceelectricalstimulationandneoprenesleeveonkneeproprioception
AT collinsambert theeffectsofstochasticresonanceelectricalstimulationandneoprenesleeveonkneeproprioception
AT dirschldouglasr theeffectsofstochasticresonanceelectricalstimulationandneoprenesleeveonkneeproprioception
AT weinholdpauls theeffectsofstochasticresonanceelectricalstimulationandneoprenesleeveonkneeproprioception
AT olcottchrisw effectsofstochasticresonanceelectricalstimulationandneoprenesleeveonkneeproprioception
AT blackburnjtroy effectsofstochasticresonanceelectricalstimulationandneoprenesleeveonkneeproprioception
AT collinsambert effectsofstochasticresonanceelectricalstimulationandneoprenesleeveonkneeproprioception
AT dirschldouglasr effectsofstochasticresonanceelectricalstimulationandneoprenesleeveonkneeproprioception
AT weinholdpauls effectsofstochasticresonanceelectricalstimulationandneoprenesleeveonkneeproprioception