3-Dimensional Modeling Guided Transcatheter Repair of Dehisced Pulmonary Venous Baffle With Gore ASD Device
A 38-year-old woman with sinus venosus atrial septal defect and partial anomalous return of the right upper pulmonary vein underwent a Warden procedure but experienced a large residual defect after patch dehiscence. Image-derived 3D modeling informed novel device closure with a Gore Cardioform atria...
Main Authors: | , , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2023-09-01
|
Series: | JACC: Case Reports |
Subjects: | |
Online Access: | http://www.sciencedirect.com/science/article/pii/S2666084923002929 |
_version_ | 1797754814130552832 |
---|---|
author | Analise Sulentic, BS Mudit Gupta, MD, PhD Silvani Amin, BA Yan Wang, RDDS Danish Vaiyani, MD Patricia Sabin, MS Sara L. Partington, MD Matthew J. Gillespie, MD Matthew A. Jolley, MD |
author_facet | Analise Sulentic, BS Mudit Gupta, MD, PhD Silvani Amin, BA Yan Wang, RDDS Danish Vaiyani, MD Patricia Sabin, MS Sara L. Partington, MD Matthew J. Gillespie, MD Matthew A. Jolley, MD |
author_sort | Analise Sulentic, BS |
collection | DOAJ |
description | A 38-year-old woman with sinus venosus atrial septal defect and partial anomalous return of the right upper pulmonary vein underwent a Warden procedure but experienced a large residual defect after patch dehiscence. Image-derived 3D modeling informed novel device closure with a Gore Cardioform atrial septal occluder. (Level of Difficulty: Advanced.) |
first_indexed | 2024-03-12T17:38:50Z |
format | Article |
id | doaj.art-935336fd21f94f45b6a8638c33b4c41a |
institution | Directory Open Access Journal |
issn | 2666-0849 |
language | English |
last_indexed | 2024-03-12T17:38:50Z |
publishDate | 2023-09-01 |
publisher | Elsevier |
record_format | Article |
series | JACC: Case Reports |
spelling | doaj.art-935336fd21f94f45b6a8638c33b4c41a2023-08-04T05:51:11ZengElsevierJACC: Case Reports2666-08492023-09-01211019683-Dimensional Modeling Guided Transcatheter Repair of Dehisced Pulmonary Venous Baffle With Gore ASD DeviceAnalise Sulentic, BS0Mudit Gupta, MD, PhD1Silvani Amin, BA2Yan Wang, RDDS3Danish Vaiyani, MD4Patricia Sabin, MS5Sara L. Partington, MD6Matthew J. Gillespie, MD7Matthew A. Jolley, MD8Department of Anesthesiology and Critical Care Medicine, Children’s Hospital of Philadelphia, Philadelphia, Pennsylvania, USADivision of Cardiology, Children’s Hospital of Philadelphia, Philadelphia, Pennsylvania, USADepartment of Anesthesiology and Critical Care Medicine, Children’s Hospital of Philadelphia, Philadelphia, Pennsylvania, USADivision of Cardiology, Children’s Hospital of Philadelphia, Philadelphia, Pennsylvania, USADivision of Cardiology, Children’s Hospital of Philadelphia, Philadelphia, Pennsylvania, USADepartment of Anesthesiology and Critical Care Medicine, Children’s Hospital of Philadelphia, Philadelphia, Pennsylvania, USADivision of Cardiology, Children’s Hospital of Philadelphia, Philadelphia, Pennsylvania, USA; Department of Medicine, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania, USADivision of Cardiology, Children’s Hospital of Philadelphia, Philadelphia, Pennsylvania, USA; Address for correspondence: Dr. Matthew J. Gillespie, Children’s Hospital of Philadelphia, 3401 Civic Center Boulevard, Philadelphia, Pennsylvania 19104, USA.Department of Anesthesiology and Critical Care Medicine, Children’s Hospital of Philadelphia, Philadelphia, Pennsylvania, USA; Division of Cardiology, Children’s Hospital of Philadelphia, Philadelphia, Pennsylvania, USAA 38-year-old woman with sinus venosus atrial septal defect and partial anomalous return of the right upper pulmonary vein underwent a Warden procedure but experienced a large residual defect after patch dehiscence. Image-derived 3D modeling informed novel device closure with a Gore Cardioform atrial septal occluder. (Level of Difficulty: Advanced.)http://www.sciencedirect.com/science/article/pii/S26660849230029293D echocardiography3D modelingcardiac MRdevice occlusionpartial anomalous pulmonary venous returnWarden procedure |
spellingShingle | Analise Sulentic, BS Mudit Gupta, MD, PhD Silvani Amin, BA Yan Wang, RDDS Danish Vaiyani, MD Patricia Sabin, MS Sara L. Partington, MD Matthew J. Gillespie, MD Matthew A. Jolley, MD 3-Dimensional Modeling Guided Transcatheter Repair of Dehisced Pulmonary Venous Baffle With Gore ASD Device JACC: Case Reports 3D echocardiography 3D modeling cardiac MR device occlusion partial anomalous pulmonary venous return Warden procedure |
title | 3-Dimensional Modeling Guided Transcatheter Repair of Dehisced Pulmonary Venous Baffle With Gore ASD Device |
title_full | 3-Dimensional Modeling Guided Transcatheter Repair of Dehisced Pulmonary Venous Baffle With Gore ASD Device |
title_fullStr | 3-Dimensional Modeling Guided Transcatheter Repair of Dehisced Pulmonary Venous Baffle With Gore ASD Device |
title_full_unstemmed | 3-Dimensional Modeling Guided Transcatheter Repair of Dehisced Pulmonary Venous Baffle With Gore ASD Device |
title_short | 3-Dimensional Modeling Guided Transcatheter Repair of Dehisced Pulmonary Venous Baffle With Gore ASD Device |
title_sort | 3 dimensional modeling guided transcatheter repair of dehisced pulmonary venous baffle with gore asd device |
topic | 3D echocardiography 3D modeling cardiac MR device occlusion partial anomalous pulmonary venous return Warden procedure |
url | http://www.sciencedirect.com/science/article/pii/S2666084923002929 |
work_keys_str_mv | AT analisesulenticbs 3dimensionalmodelingguidedtranscatheterrepairofdehiscedpulmonaryvenousbafflewithgoreasddevice AT muditguptamdphd 3dimensionalmodelingguidedtranscatheterrepairofdehiscedpulmonaryvenousbafflewithgoreasddevice AT silvaniaminba 3dimensionalmodelingguidedtranscatheterrepairofdehiscedpulmonaryvenousbafflewithgoreasddevice AT yanwangrdds 3dimensionalmodelingguidedtranscatheterrepairofdehiscedpulmonaryvenousbafflewithgoreasddevice AT danishvaiyanimd 3dimensionalmodelingguidedtranscatheterrepairofdehiscedpulmonaryvenousbafflewithgoreasddevice AT patriciasabinms 3dimensionalmodelingguidedtranscatheterrepairofdehiscedpulmonaryvenousbafflewithgoreasddevice AT saralpartingtonmd 3dimensionalmodelingguidedtranscatheterrepairofdehiscedpulmonaryvenousbafflewithgoreasddevice AT matthewjgillespiemd 3dimensionalmodelingguidedtranscatheterrepairofdehiscedpulmonaryvenousbafflewithgoreasddevice AT matthewajolleymd 3dimensionalmodelingguidedtranscatheterrepairofdehiscedpulmonaryvenousbafflewithgoreasddevice |