Evaluation of Fungi Presence in the Air of Two Broiler Houses with Different Ventilation Systems
The aim of this study was to evaluate the presence of fungi in two distinct types of broiler houses. The research compared two types of air ventilation: conventional and positive tunnel ventilation. Two different techniques were applied simultaneously for the air borne microorganisms (mesophilic bac...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Agroprint Timisoara
2023-10-01
|
Series: | Scientific Papers Animal Science and Biotechnologies |
Subjects: | |
Online Access: | https://spasb.ro/index.php/public_html/article/view/1309 |
_version_ | 1797215704791908352 |
---|---|
author | Ileana Nichita Adela Marcu Monica Seres Emil Tirziu Daniela Mot Radu Valentin Gros |
author_facet | Ileana Nichita Adela Marcu Monica Seres Emil Tirziu Daniela Mot Radu Valentin Gros |
author_sort | Ileana Nichita |
collection | DOAJ |
description | The aim of this study was to evaluate the presence of fungi in two distinct types of broiler houses. The research compared two types of air ventilation: conventional and positive tunnel ventilation. Two different techniques were applied simultaneously for the air borne microorganisms (mesophilic bacteria and fungi) trapping: air aspiration using the air collector SAS 100TM and sedimentation method. High concentrations of fungal spores were detected in the conventional ventilated poultry house. Species of Aspergillus fumigatus, Aspergillus flavus, Penicillium crysogenum, Cladosporium cladosporioides, Scopulariopsis, prevailed in both poultry houses. The majority of the identified fungal species are characterized as allergenic and an exposure to their spores may provoke adverse health effects. |
first_indexed | 2024-04-24T11:34:18Z |
format | Article |
id | doaj.art-9376b952a5244c6ebf7437c6e6625ec0 |
institution | Directory Open Access Journal |
issn | 1841-9364 2344-4576 |
language | English |
last_indexed | 2024-04-24T11:34:18Z |
publishDate | 2023-10-01 |
publisher | Agroprint Timisoara |
record_format | Article |
series | Scientific Papers Animal Science and Biotechnologies |
spelling | doaj.art-9376b952a5244c6ebf7437c6e6625ec02024-04-10T06:55:41ZengAgroprint TimisoaraScientific Papers Animal Science and Biotechnologies1841-93642344-45762023-10-014314154151309Evaluation of Fungi Presence in the Air of Two Broiler Houses with Different Ventilation SystemsIleana Nichita0Adela Marcu1Monica Seres2Emil Tirziu3Daniela Mot4Radu Valentin Gros5Faculty of Veterinary Medicine – 300645, Timisoara,119 Aradului Street RomaniaFaculty of Animals Sciences and Biotechnology – 300645, Timisoara,119 Aradului Street RomaniaFaculty of Veterinary Medicine – 300645, Timisoara,119 Aradului Street RomaniaFaculty of Veterinary Medicine – 300645, Timisoara,119 Aradului Street RomaniaFaculty of Animals Sciences and Biotechnology – 300645, Timisoara,119 Aradului Street RomaniaFaculty of Animals Sciences and Biotechnology – 300645, Timisoara,119 Aradului Street RomaniaThe aim of this study was to evaluate the presence of fungi in two distinct types of broiler houses. The research compared two types of air ventilation: conventional and positive tunnel ventilation. Two different techniques were applied simultaneously for the air borne microorganisms (mesophilic bacteria and fungi) trapping: air aspiration using the air collector SAS 100TM and sedimentation method. High concentrations of fungal spores were detected in the conventional ventilated poultry house. Species of Aspergillus fumigatus, Aspergillus flavus, Penicillium crysogenum, Cladosporium cladosporioides, Scopulariopsis, prevailed in both poultry houses. The majority of the identified fungal species are characterized as allergenic and an exposure to their spores may provoke adverse health effects.https://spasb.ro/index.php/public_html/article/view/1309fungiairbroiler houses |
spellingShingle | Ileana Nichita Adela Marcu Monica Seres Emil Tirziu Daniela Mot Radu Valentin Gros Evaluation of Fungi Presence in the Air of Two Broiler Houses with Different Ventilation Systems Scientific Papers Animal Science and Biotechnologies fungi air broiler houses |
title | Evaluation of Fungi Presence in the Air of Two Broiler Houses with Different Ventilation Systems |
title_full | Evaluation of Fungi Presence in the Air of Two Broiler Houses with Different Ventilation Systems |
title_fullStr | Evaluation of Fungi Presence in the Air of Two Broiler Houses with Different Ventilation Systems |
title_full_unstemmed | Evaluation of Fungi Presence in the Air of Two Broiler Houses with Different Ventilation Systems |
title_short | Evaluation of Fungi Presence in the Air of Two Broiler Houses with Different Ventilation Systems |
title_sort | evaluation of fungi presence in the air of two broiler houses with different ventilation systems |
topic | fungi air broiler houses |
url | https://spasb.ro/index.php/public_html/article/view/1309 |
work_keys_str_mv | AT ileananichita evaluationoffungipresenceintheairoftwobroilerhouseswithdifferentventilationsystems AT adelamarcu evaluationoffungipresenceintheairoftwobroilerhouseswithdifferentventilationsystems AT monicaseres evaluationoffungipresenceintheairoftwobroilerhouseswithdifferentventilationsystems AT emiltirziu evaluationoffungipresenceintheairoftwobroilerhouseswithdifferentventilationsystems AT danielamot evaluationoffungipresenceintheairoftwobroilerhouseswithdifferentventilationsystems AT raduvalentingros evaluationoffungipresenceintheairoftwobroilerhouseswithdifferentventilationsystems |