Influence of cooling air selections on the efficiency of a gas turbine installation
A gas turbine installation (GTI) consists of 5 main parts: an input device, a compressor, a combustion chamber, a gas turbine, and an output device. In this work, due to the lack of sufficiently extensive information about stationary GTI, data from the characteristics of aviation GTI were partially...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Kazan State Power Engineering University
2020-11-01
|
Series: | Известия высших учебных заведений: Проблемы энергетики |
Subjects: | |
Online Access: | https://www.energyret.ru/jour/article/view/1403 |
_version_ | 1797758449658888192 |
---|---|
author | I. I. Mubarakov A. B. Shigapov |
author_facet | I. I. Mubarakov A. B. Shigapov |
author_sort | I. I. Mubarakov |
collection | DOAJ |
description | A gas turbine installation (GTI) consists of 5 main parts: an input device, a compressor, a combustion chamber, a gas turbine, and an output device. In this work, due to the lack of sufficiently extensive information about stationary GTI, data from the characteristics of aviation GTI were partially used. The GTI operation efficiency is influenced by many factors, among which, apparently, the determining factor is the degree of air compression in the compressor π К . Of course, the compression ratio depends on the design scheme of the gas turbine, the type of fuel, the climatic conditions of operation, and others. The most important operational parameter of the GTI is the effective power NP and specific fuel consumption bud . The article provides a numerical analysis of the effect π К on NP and bud under variations in the temperature of gases at the turbine inlet T3 , as well as the influence of other factors, including the selection of part of the air for cooling high-temperature surfaces of the structure. The conclusions were made based on the calculations, the results of which are shown in the tables, and in the comparison graphs of obtained results. |
first_indexed | 2024-03-12T18:30:08Z |
format | Article |
id | doaj.art-941930ce962d41edb56098c75e6057da |
institution | Directory Open Access Journal |
issn | 1998-9903 |
language | English |
last_indexed | 2024-03-12T18:30:08Z |
publishDate | 2020-11-01 |
publisher | Kazan State Power Engineering University |
record_format | Article |
series | Известия высших учебных заведений: Проблемы энергетики |
spelling | doaj.art-941930ce962d41edb56098c75e6057da2023-08-02T08:20:42ZengKazan State Power Engineering UniversityИзвестия высших учебных заведений: Проблемы энергетики1998-99032020-11-01224162310.30724/1998-9903-2020-22-4-16-23681Influence of cooling air selections on the efficiency of a gas turbine installationI. I. Mubarakov0A. B. Shigapov1Kazan State Power Engineering UniversityKazan State Power Engineering UniversityA gas turbine installation (GTI) consists of 5 main parts: an input device, a compressor, a combustion chamber, a gas turbine, and an output device. In this work, due to the lack of sufficiently extensive information about stationary GTI, data from the characteristics of aviation GTI were partially used. The GTI operation efficiency is influenced by many factors, among which, apparently, the determining factor is the degree of air compression in the compressor π К . Of course, the compression ratio depends on the design scheme of the gas turbine, the type of fuel, the climatic conditions of operation, and others. The most important operational parameter of the GTI is the effective power NP and specific fuel consumption bud . The article provides a numerical analysis of the effect π К on NP and bud under variations in the temperature of gases at the turbine inlet T3 , as well as the influence of other factors, including the selection of part of the air for cooling high-temperature surfaces of the structure. The conclusions were made based on the calculations, the results of which are shown in the tables, and in the comparison graphs of obtained results.https://www.energyret.ru/jour/article/view/1403gtian optimal compression ratio in the compressorthe effective powerbleed airinfluence |
spellingShingle | I. I. Mubarakov A. B. Shigapov Influence of cooling air selections on the efficiency of a gas turbine installation Известия высших учебных заведений: Проблемы энергетики gti an optimal compression ratio in the compressor the effective power bleed air influence |
title | Influence of cooling air selections on the efficiency of a gas turbine installation |
title_full | Influence of cooling air selections on the efficiency of a gas turbine installation |
title_fullStr | Influence of cooling air selections on the efficiency of a gas turbine installation |
title_full_unstemmed | Influence of cooling air selections on the efficiency of a gas turbine installation |
title_short | Influence of cooling air selections on the efficiency of a gas turbine installation |
title_sort | influence of cooling air selections on the efficiency of a gas turbine installation |
topic | gti an optimal compression ratio in the compressor the effective power bleed air influence |
url | https://www.energyret.ru/jour/article/view/1403 |
work_keys_str_mv | AT iimubarakov influenceofcoolingairselectionsontheefficiencyofagasturbineinstallation AT abshigapov influenceofcoolingairselectionsontheefficiencyofagasturbineinstallation |