Assessment of Radiation-Induced Malfunction in Cardiac Implantable Electronic Devices

Background: Radiation therapy (RT) is a standard cancer treatment modality, and an increasing number of patients with cardiac implantable electronic devices (CIEDs) are being referred for RT. The goals of this study were as follows: (i) to determine the incidence of CIED malfunction following RT; (i...

Full description

Bibliographic Details
Main Authors: Amin Zagzoog, MBBS, Matt Wronski, PhD, David H. Birnie, MD, Cynthia Yeung, BSc, Adrian Baranchuk, MD, Jeffrey S. Healey, MD, FHRS, Mehrdad Golian, MD, Usama Boles, MBChB, MS, PhD, Aldo G. Carrizo, MD, Suzette Turner, MS, NP, Ahmed Hassan, MD, Elsayed Ali, PhD, Sharath K. Kumar, MBBS, Steve Russell, BSc, Mohammed Shurrab, MD, Eugene Crystal, MD
Format: Article
Language:English
Published: Elsevier 2021-12-01
Series:CJC Open
Online Access:http://www.sciencedirect.com/science/article/pii/S2589790X2100189X
_version_ 1818974161032183808
author Amin Zagzoog, MBBS
Matt Wronski, PhD
David H. Birnie, MD
Cynthia Yeung, BSc
Adrian Baranchuk, MD
Jeffrey S. Healey, MD, FHRS
Mehrdad Golian, MD
Usama Boles, MBChB, MS, PhD
Aldo G. Carrizo, MD
Suzette Turner, MS, NP
Ahmed Hassan, MD
Elsayed Ali, PhD
Sharath K. Kumar, MBBS
Steve Russell, BSc
Mohammed Shurrab, MD
Eugene Crystal, MD
author_facet Amin Zagzoog, MBBS
Matt Wronski, PhD
David H. Birnie, MD
Cynthia Yeung, BSc
Adrian Baranchuk, MD
Jeffrey S. Healey, MD, FHRS
Mehrdad Golian, MD
Usama Boles, MBChB, MS, PhD
Aldo G. Carrizo, MD
Suzette Turner, MS, NP
Ahmed Hassan, MD
Elsayed Ali, PhD
Sharath K. Kumar, MBBS
Steve Russell, BSc
Mohammed Shurrab, MD
Eugene Crystal, MD
author_sort Amin Zagzoog, MBBS
collection DOAJ
description Background: Radiation therapy (RT) is a standard cancer treatment modality, and an increasing number of patients with cardiac implantable electronic devices (CIEDs) are being referred for RT. The goals of this study were as follows: (i) to determine the incidence of CIED malfunction following RT; (ii) to characterize the various types of malfunctions that occur; and (iii) to identify risk factors associated with CIED malfunction following RT. Methods: A retrospective study of patients with CIEDs who received RT between 2007 and 2018 at 4 Canadian centres (Sunnybrook Health Sciences Centre, Kingston General Hospital, Hamilton Health Sciences Centre, and University of Ottawa Heart Institute) was conducted. Patients underwent CIED interrogation after completion of RT, to assess for late damage to the CIEDs. Data on demographics, devices, and RT were compared for the primary outcome of device malfunction. Results: Of 1041 patients with CIEDs who received RT, 811 patients with complete data were included. Device malfunctions occurred in 32 of 811 patients (4%). The most common device malfunctions were reduced ventricular/atrial sensing (in 13 of 32 [41%]), an increase in lead threshold (in 9 of 32 [22%]), lead noise (in 5 of 32 [16%]), and electrical reset (in 2 of 32 [6%]). Higher beam energy (≥ 10 MV) was associated with malfunction (P < 0.0001). Radiation dose was not significantly different between the malfunction and non-malfunction groups (58.3 cGy vs 65 cGy, respectively, P = 0.71). Conclusions: Although RT-induced CIED malfunctions are rare (occurring in 4% of patients with a CIED who undergo RT), collaborative efforts between radiation oncologists and cardiac rhythm device clinics to optimize CIED monitoring are needed, to detect and manage CIED malfunctions. Malfunctions are more common in patients receiving higher–beam energy (≥10MV)RT. Résumé: Contexte: La radiothérapie (RT) est une modalité standard de traitement du cancer, et un nombre croissant de patients porteurs de dispositifs cardiaques électroniques implantables (DCEI) doivent recevoir un traitement de RT. Les objectifs de cette étude étaient les suivants : (i) déterminer l’incidence d’une défaillance du DCEI après une RT; (ii) caractériser les différents types de défaillances qui se produisent; (iii) déterminer les facteurs de risque associés à la défaillance du DCEI après une RT. Méthodologie: Une étude rétrospective des patients avec un DCEI ayant reçu une RT entre 2007 et 2018 dans quatre centres canadiens (Sunnybrook Health Sciences Centre, Kingston General Hospital, Hamilton Health Sciences Centre et Institut de cardiologie de l’Université d’Ottawa) a été menée. Le DCEI des patients a été interrogé après la fin de la RT, pour en évaluer les dommages tardifs. Les données sur les caractéristiques démographiques, les dispositifs et la RT ont été comparées pour le paramètre d’évaluation principal, soit la défaillance du dispositif. Résultats: Sur les 1 041 patients avec un DCEI ayant reçu une RT, 811 patients avec des données complètes ont été inclus. Des défaillances du dispositif sont survenues chez 32 des 811 patients (4 %). Les défaillances les plus fréquentes du dispositif étaient une détection ventriculaire/atriale réduite (chez 13 des 32 patients [41 %]), une augmentation du seuil de la sonde (chez 9 des 32 patients [22 %]), un bruit provenant de la sonde (chez 5 des 32 patients [16 %]) et une réinitialisation électrique (chez 2 des 32 patients [6 %]). Une énergie de faisceau plus élevée (≥ 10 MV) était associée à une défaillance (p < 0,0001). La dose de rayonnement ne présentait pas de différence significative entre le groupe où une défaillance a été constatée et l’autre groupe (58,3 cGy vs 65 cGy, respectivement, p = 0,71). Conclusions: Bien que les défaillances du DCEI causées par la RT soient rares (survenant chez 4 % des patients avec un DCEI qui subissent une RT), une collaboration est nécessaire entre les radio-oncologues et les cliniques de dispositifs de gestion du rythme cardiaque, afin d’optimiser la surveillance du DCEI et de détecter et de gérer ces défaillances. Les défaillances sont plus fréquentes chez les patients recevant une énergie de faisceau plus élevée au moment de la RT (≥10MV).
first_indexed 2024-12-20T15:35:39Z
format Article
id doaj.art-94c31143a2fa4f54b3e365621e662ce2
institution Directory Open Access Journal
issn 2589-790X
language English
last_indexed 2024-12-20T15:35:39Z
publishDate 2021-12-01
publisher Elsevier
record_format Article
series CJC Open
spelling doaj.art-94c31143a2fa4f54b3e365621e662ce22022-12-21T19:35:26ZengElsevierCJC Open2589-790X2021-12-0131214381443Assessment of Radiation-Induced Malfunction in Cardiac Implantable Electronic DevicesAmin Zagzoog, MBBS0Matt Wronski, PhD1David H. Birnie, MD2Cynthia Yeung, BSc3Adrian Baranchuk, MD4Jeffrey S. Healey, MD, FHRS5Mehrdad Golian, MD6Usama Boles, MBChB, MS, PhD7Aldo G. Carrizo, MD8Suzette Turner, MS, NP9Ahmed Hassan, MD10Elsayed Ali, PhD11Sharath K. Kumar, MBBS12Steve Russell, BSc13Mohammed Shurrab, MD14Eugene Crystal, MD15Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada; University of Ottawa Heart Institute, University of Ottawa, Ottawa, Ontario, CanadaSunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, CanadaUniversity of Ottawa Heart Institute, University of Ottawa, Ottawa, Ontario, CanadaKingston General Hospital, Queens School of Medicine, Kingston, Ontario, CanadaKingston General Hospital, Queens School of Medicine, Kingston, Ontario, CanadaHamilton Health Sciences and Centre, McMaster University, Hamilton, Ontario, CanadaUniversity of Ottawa Heart Institute, University of Ottawa, Ottawa, Ontario, CanadaKingston General Hospital, Queens School of Medicine, Kingston, Ontario, CanadaHamilton Health Sciences and Centre, McMaster University, Hamilton, Ontario, CanadaSunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, CanadaUniversity of Ottawa Heart Institute, University of Ottawa, Ottawa, Ontario, CanadaThe Ottawa Hospital Cancer Centre, University of Ottawa, Ottawa, Ontario, CanadaSunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, CanadaSunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, CanadaHealth Sciences North, Health Sciences North Research Institute, Northern Ontario School of Medicine, Sudbury, Ontario, CanadaSunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada; Corresponding author: Dr Eugene Crystal, Division of Cardiology, Department of Medicine, D377, 2075 Bayview Ave, Toronto, Onntario M4N 3M5, Canada. Tel.: +1-416-480-6100.Background: Radiation therapy (RT) is a standard cancer treatment modality, and an increasing number of patients with cardiac implantable electronic devices (CIEDs) are being referred for RT. The goals of this study were as follows: (i) to determine the incidence of CIED malfunction following RT; (ii) to characterize the various types of malfunctions that occur; and (iii) to identify risk factors associated with CIED malfunction following RT. Methods: A retrospective study of patients with CIEDs who received RT between 2007 and 2018 at 4 Canadian centres (Sunnybrook Health Sciences Centre, Kingston General Hospital, Hamilton Health Sciences Centre, and University of Ottawa Heart Institute) was conducted. Patients underwent CIED interrogation after completion of RT, to assess for late damage to the CIEDs. Data on demographics, devices, and RT were compared for the primary outcome of device malfunction. Results: Of 1041 patients with CIEDs who received RT, 811 patients with complete data were included. Device malfunctions occurred in 32 of 811 patients (4%). The most common device malfunctions were reduced ventricular/atrial sensing (in 13 of 32 [41%]), an increase in lead threshold (in 9 of 32 [22%]), lead noise (in 5 of 32 [16%]), and electrical reset (in 2 of 32 [6%]). Higher beam energy (≥ 10 MV) was associated with malfunction (P < 0.0001). Radiation dose was not significantly different between the malfunction and non-malfunction groups (58.3 cGy vs 65 cGy, respectively, P = 0.71). Conclusions: Although RT-induced CIED malfunctions are rare (occurring in 4% of patients with a CIED who undergo RT), collaborative efforts between radiation oncologists and cardiac rhythm device clinics to optimize CIED monitoring are needed, to detect and manage CIED malfunctions. Malfunctions are more common in patients receiving higher–beam energy (≥10MV)RT. Résumé: Contexte: La radiothérapie (RT) est une modalité standard de traitement du cancer, et un nombre croissant de patients porteurs de dispositifs cardiaques électroniques implantables (DCEI) doivent recevoir un traitement de RT. Les objectifs de cette étude étaient les suivants : (i) déterminer l’incidence d’une défaillance du DCEI après une RT; (ii) caractériser les différents types de défaillances qui se produisent; (iii) déterminer les facteurs de risque associés à la défaillance du DCEI après une RT. Méthodologie: Une étude rétrospective des patients avec un DCEI ayant reçu une RT entre 2007 et 2018 dans quatre centres canadiens (Sunnybrook Health Sciences Centre, Kingston General Hospital, Hamilton Health Sciences Centre et Institut de cardiologie de l’Université d’Ottawa) a été menée. Le DCEI des patients a été interrogé après la fin de la RT, pour en évaluer les dommages tardifs. Les données sur les caractéristiques démographiques, les dispositifs et la RT ont été comparées pour le paramètre d’évaluation principal, soit la défaillance du dispositif. Résultats: Sur les 1 041 patients avec un DCEI ayant reçu une RT, 811 patients avec des données complètes ont été inclus. Des défaillances du dispositif sont survenues chez 32 des 811 patients (4 %). Les défaillances les plus fréquentes du dispositif étaient une détection ventriculaire/atriale réduite (chez 13 des 32 patients [41 %]), une augmentation du seuil de la sonde (chez 9 des 32 patients [22 %]), un bruit provenant de la sonde (chez 5 des 32 patients [16 %]) et une réinitialisation électrique (chez 2 des 32 patients [6 %]). Une énergie de faisceau plus élevée (≥ 10 MV) était associée à une défaillance (p < 0,0001). La dose de rayonnement ne présentait pas de différence significative entre le groupe où une défaillance a été constatée et l’autre groupe (58,3 cGy vs 65 cGy, respectivement, p = 0,71). Conclusions: Bien que les défaillances du DCEI causées par la RT soient rares (survenant chez 4 % des patients avec un DCEI qui subissent une RT), une collaboration est nécessaire entre les radio-oncologues et les cliniques de dispositifs de gestion du rythme cardiaque, afin d’optimiser la surveillance du DCEI et de détecter et de gérer ces défaillances. Les défaillances sont plus fréquentes chez les patients recevant une énergie de faisceau plus élevée au moment de la RT (≥10MV).http://www.sciencedirect.com/science/article/pii/S2589790X2100189X
spellingShingle Amin Zagzoog, MBBS
Matt Wronski, PhD
David H. Birnie, MD
Cynthia Yeung, BSc
Adrian Baranchuk, MD
Jeffrey S. Healey, MD, FHRS
Mehrdad Golian, MD
Usama Boles, MBChB, MS, PhD
Aldo G. Carrizo, MD
Suzette Turner, MS, NP
Ahmed Hassan, MD
Elsayed Ali, PhD
Sharath K. Kumar, MBBS
Steve Russell, BSc
Mohammed Shurrab, MD
Eugene Crystal, MD
Assessment of Radiation-Induced Malfunction in Cardiac Implantable Electronic Devices
CJC Open
title Assessment of Radiation-Induced Malfunction in Cardiac Implantable Electronic Devices
title_full Assessment of Radiation-Induced Malfunction in Cardiac Implantable Electronic Devices
title_fullStr Assessment of Radiation-Induced Malfunction in Cardiac Implantable Electronic Devices
title_full_unstemmed Assessment of Radiation-Induced Malfunction in Cardiac Implantable Electronic Devices
title_short Assessment of Radiation-Induced Malfunction in Cardiac Implantable Electronic Devices
title_sort assessment of radiation induced malfunction in cardiac implantable electronic devices
url http://www.sciencedirect.com/science/article/pii/S2589790X2100189X
work_keys_str_mv AT aminzagzoogmbbs assessmentofradiationinducedmalfunctionincardiacimplantableelectronicdevices
AT mattwronskiphd assessmentofradiationinducedmalfunctionincardiacimplantableelectronicdevices
AT davidhbirniemd assessmentofradiationinducedmalfunctionincardiacimplantableelectronicdevices
AT cynthiayeungbsc assessmentofradiationinducedmalfunctionincardiacimplantableelectronicdevices
AT adrianbaranchukmd assessmentofradiationinducedmalfunctionincardiacimplantableelectronicdevices
AT jeffreyshealeymdfhrs assessmentofradiationinducedmalfunctionincardiacimplantableelectronicdevices
AT mehrdadgolianmd assessmentofradiationinducedmalfunctionincardiacimplantableelectronicdevices
AT usamabolesmbchbmsphd assessmentofradiationinducedmalfunctionincardiacimplantableelectronicdevices
AT aldogcarrizomd assessmentofradiationinducedmalfunctionincardiacimplantableelectronicdevices
AT suzetteturnermsnp assessmentofradiationinducedmalfunctionincardiacimplantableelectronicdevices
AT ahmedhassanmd assessmentofradiationinducedmalfunctionincardiacimplantableelectronicdevices
AT elsayedaliphd assessmentofradiationinducedmalfunctionincardiacimplantableelectronicdevices
AT sharathkkumarmbbs assessmentofradiationinducedmalfunctionincardiacimplantableelectronicdevices
AT steverussellbsc assessmentofradiationinducedmalfunctionincardiacimplantableelectronicdevices
AT mohammedshurrabmd assessmentofradiationinducedmalfunctionincardiacimplantableelectronicdevices
AT eugenecrystalmd assessmentofradiationinducedmalfunctionincardiacimplantableelectronicdevices