Aortic Pseudo aneurysm 3 Years after Interposition Tube Graft for Acute Dissection of Ascending Aorta

Introduction: Patients with primary acute aortic dissection are at higher risk of complications, including increasing aortic aneurysm diameter, aortic rupture, aortic pseudo aneurysm, and recurrent aortic dissection. Case presentation We presented the case of a recurrent pseudo aneurysm and rupture...

Full description

Bibliographic Details
Main Authors: Aliasghar Moeinipour, Mohammad Abbassi Teshnisi, Mohamadreza Akbari, Kayhan Mizani, Mahsa Moallemi, Omid Javdanfar, Hamid Hoseinikhah
Format: Article
Language:English
Published: Mashhad University of Medical Sciences 2019-06-01
Series:Journal of Cardio-Thoracic Medicine
Subjects:
Online Access:http://jctm.mums.ac.ir/article_13256_e6ad539ab57a65dd713dafc1bff5e2be.pdf
_version_ 1818472234389340160
author Aliasghar Moeinipour
Mohammad Abbassi Teshnisi
Mohamadreza Akbari
Kayhan Mizani
Mahsa Moallemi
Omid Javdanfar
Hamid Hoseinikhah
author_facet Aliasghar Moeinipour
Mohammad Abbassi Teshnisi
Mohamadreza Akbari
Kayhan Mizani
Mahsa Moallemi
Omid Javdanfar
Hamid Hoseinikhah
author_sort Aliasghar Moeinipour
collection DOAJ
description Introduction: Patients with primary acute aortic dissection are at higher risk of complications, including increasing aortic aneurysm diameter, aortic rupture, aortic pseudo aneurysm, and recurrent aortic dissection. Case presentation We presented the case of a recurrent pseudo aneurysm and rupture of the aorta in the distal ascending aorta and proximal arch 3 years after the initial procedure for acute aortic dissection. The patient had bleeding from previous skin incision. In computed tomography angiography, the site of rupture of the aorta and abnormal communication with sternum were confirmed. Conclusion Recurrent aortic dissection is a catastrophic event and has high mortality; however, it is rare and is treated in a short time by redo surgery.
first_indexed 2024-04-14T04:03:52Z
format Article
id doaj.art-9513c7a7fd6d43aaa2ab0602b1de4758
institution Directory Open Access Journal
issn 2345-2447
2322-5750
language English
last_indexed 2024-04-14T04:03:52Z
publishDate 2019-06-01
publisher Mashhad University of Medical Sciences
record_format Article
series Journal of Cardio-Thoracic Medicine
spelling doaj.art-9513c7a7fd6d43aaa2ab0602b1de47582022-12-22T02:13:27ZengMashhad University of Medical SciencesJournal of Cardio-Thoracic Medicine2345-24472322-57502019-06-017245345510.22038/jctm.2019.40342.122513256Aortic Pseudo aneurysm 3 Years after Interposition Tube Graft for Acute Dissection of Ascending AortaAliasghar Moeinipour0Mohammad Abbassi Teshnisi1Mohamadreza Akbari2Kayhan Mizani3Mahsa Moallemi4Omid Javdanfar5Hamid Hoseinikhah6Cardiac Surgeon, Department of Cardiac Surgery, Mashhad University of Medical Sciences, Mashhad, Iran.Cardiac Surgeon, Department of Cardiac Surgery, Mashhad University of Medical Sciences, Mashhad, Iran.General Physician, Faculty of medical science, Mashhad University of Medical Sciences, Mashhad, Iran.Student Research Committee, Faculty of medicine, Mashhad University of Medical Sciences, Mashhad, Iran.Student Research Committee, Faculty of medicine, Mashhad University of Medical Sciences, Mashhad, Iran.Resident of Cardiac Surgery, Department of Cardiac Surgery, Faculty of Medical Science, Mashhad University of Medical Sciences, Mashhad, IranCardiac Surgeon, Department of Cardiac Surgery, Mashhad University of Medical Sciences, Mashhad, Iran.Introduction: Patients with primary acute aortic dissection are at higher risk of complications, including increasing aortic aneurysm diameter, aortic rupture, aortic pseudo aneurysm, and recurrent aortic dissection. Case presentation We presented the case of a recurrent pseudo aneurysm and rupture of the aorta in the distal ascending aorta and proximal arch 3 years after the initial procedure for acute aortic dissection. The patient had bleeding from previous skin incision. In computed tomography angiography, the site of rupture of the aorta and abnormal communication with sternum were confirmed. Conclusion Recurrent aortic dissection is a catastrophic event and has high mortality; however, it is rare and is treated in a short time by redo surgery.http://jctm.mums.ac.ir/article_13256_e6ad539ab57a65dd713dafc1bff5e2be.pdfAortic DissectionAortic PseudoaneurysmCardiac Surgery
spellingShingle Aliasghar Moeinipour
Mohammad Abbassi Teshnisi
Mohamadreza Akbari
Kayhan Mizani
Mahsa Moallemi
Omid Javdanfar
Hamid Hoseinikhah
Aortic Pseudo aneurysm 3 Years after Interposition Tube Graft for Acute Dissection of Ascending Aorta
Journal of Cardio-Thoracic Medicine
Aortic Dissection
Aortic Pseudoaneurysm
Cardiac Surgery
title Aortic Pseudo aneurysm 3 Years after Interposition Tube Graft for Acute Dissection of Ascending Aorta
title_full Aortic Pseudo aneurysm 3 Years after Interposition Tube Graft for Acute Dissection of Ascending Aorta
title_fullStr Aortic Pseudo aneurysm 3 Years after Interposition Tube Graft for Acute Dissection of Ascending Aorta
title_full_unstemmed Aortic Pseudo aneurysm 3 Years after Interposition Tube Graft for Acute Dissection of Ascending Aorta
title_short Aortic Pseudo aneurysm 3 Years after Interposition Tube Graft for Acute Dissection of Ascending Aorta
title_sort aortic pseudo aneurysm 3 years after interposition tube graft for acute dissection of ascending aorta
topic Aortic Dissection
Aortic Pseudoaneurysm
Cardiac Surgery
url http://jctm.mums.ac.ir/article_13256_e6ad539ab57a65dd713dafc1bff5e2be.pdf
work_keys_str_mv AT aliasgharmoeinipour aorticpseudoaneurysm3yearsafterinterpositiontubegraftforacutedissectionofascendingaorta
AT mohammadabbassiteshnisi aorticpseudoaneurysm3yearsafterinterpositiontubegraftforacutedissectionofascendingaorta
AT mohamadrezaakbari aorticpseudoaneurysm3yearsafterinterpositiontubegraftforacutedissectionofascendingaorta
AT kayhanmizani aorticpseudoaneurysm3yearsafterinterpositiontubegraftforacutedissectionofascendingaorta
AT mahsamoallemi aorticpseudoaneurysm3yearsafterinterpositiontubegraftforacutedissectionofascendingaorta
AT omidjavdanfar aorticpseudoaneurysm3yearsafterinterpositiontubegraftforacutedissectionofascendingaorta
AT hamidhoseinikhah aorticpseudoaneurysm3yearsafterinterpositiontubegraftforacutedissectionofascendingaorta