Evaluasi Jaringan Tegangan Menengah Pasca Bencana Di Kabupaten Halmahera Selatan

This study looked at the condition of power loss and falling voltage after the evaluation of the medium voltage network 20 kV after the earthquake disaster in South Halmahera district, especially in labuha extension on Bacan island The method used in this study is a quantitative research method with...

Full description

Bibliographic Details
Main Author: Ramly Rasyid
Format: Article
Language:Indonesian
Published: Department of Electrical Engineering, Universitas Patria Artha 2020-10-01
Series:Patria Artha Technological Journal
Subjects:
Online Access:http://ejournal.patria-artha.ac.id/index.php/patj/article/view/355
_version_ 1827313352383135744
author Ramly Rasyid
author_facet Ramly Rasyid
author_sort Ramly Rasyid
collection DOAJ
description This study looked at the condition of power loss and falling voltage after the evaluation of the medium voltage network 20 kV after the earthquake disaster in South Halmahera district, especially in labuha extension on Bacan island The method used in this study is a quantitative research method with data collection done which is then simulated using ETAP 12.6 software. The simulation result obtained total power loss at Labuha extension is 44.3 kW, 66.8 kVAR or 80,154 kVA of 2,445 MVA delivery power, while the presentation of power loss is 3.278%, this is still considered feasible because the power loss on the medium voltage network 20 kV is 10% while in Labuha turtles the power loss is less than 10%. While the large fall in voltage at the largest Labuha extension at the Belang-Belang distribution substation is 3.96% or 792 volts, this is due to the channel length and presentation of the load reaching 83% against the distribution tranformator and the fall in the average voltage of Labuha's purgator is 3.025% or 605 volts against the nominal voltage of 20 kV. It is still considered viable for operation due to the permitted voltage fall on the 20 kV medium voltage network which is 5%.
first_indexed 2024-04-24T22:07:04Z
format Article
id doaj.art-9587e6dacd5f4383b8c11f38aa21db84
institution Directory Open Access Journal
issn 2549-6131
2549-614X
language Indonesian
last_indexed 2024-04-24T22:07:04Z
publishDate 2020-10-01
publisher Department of Electrical Engineering, Universitas Patria Artha
record_format Article
series Patria Artha Technological Journal
spelling doaj.art-9587e6dacd5f4383b8c11f38aa21db842024-03-20T11:44:07ZindDepartment of Electrical Engineering, Universitas Patria ArthaPatria Artha Technological Journal2549-61312549-614X2020-10-01429110010.33857/patj.v4i2.355257Evaluasi Jaringan Tegangan Menengah Pasca Bencana Di Kabupaten Halmahera SelatanRamly Rasyid0Jurusan Teknik Elektro Universitas Khairun.This study looked at the condition of power loss and falling voltage after the evaluation of the medium voltage network 20 kV after the earthquake disaster in South Halmahera district, especially in labuha extension on Bacan island The method used in this study is a quantitative research method with data collection done which is then simulated using ETAP 12.6 software. The simulation result obtained total power loss at Labuha extension is 44.3 kW, 66.8 kVAR or 80,154 kVA of 2,445 MVA delivery power, while the presentation of power loss is 3.278%, this is still considered feasible because the power loss on the medium voltage network 20 kV is 10% while in Labuha turtles the power loss is less than 10%. While the large fall in voltage at the largest Labuha extension at the Belang-Belang distribution substation is 3.96% or 792 volts, this is due to the channel length and presentation of the load reaching 83% against the distribution tranformator and the fall in the average voltage of Labuha's purgator is 3.025% or 605 volts against the nominal voltage of 20 kV. It is still considered viable for operation due to the permitted voltage fall on the 20 kV medium voltage network which is 5%.http://ejournal.patria-artha.ac.id/index.php/patj/article/view/355evaluasi jaringan distribusi 20 kv, rugi daya, jatuh tegangan,,etap 12.6.
spellingShingle Ramly Rasyid
Evaluasi Jaringan Tegangan Menengah Pasca Bencana Di Kabupaten Halmahera Selatan
Patria Artha Technological Journal
evaluasi jaringan distribusi 20 kv, rugi daya, jatuh tegangan,,etap 12.6.
title Evaluasi Jaringan Tegangan Menengah Pasca Bencana Di Kabupaten Halmahera Selatan
title_full Evaluasi Jaringan Tegangan Menengah Pasca Bencana Di Kabupaten Halmahera Selatan
title_fullStr Evaluasi Jaringan Tegangan Menengah Pasca Bencana Di Kabupaten Halmahera Selatan
title_full_unstemmed Evaluasi Jaringan Tegangan Menengah Pasca Bencana Di Kabupaten Halmahera Selatan
title_short Evaluasi Jaringan Tegangan Menengah Pasca Bencana Di Kabupaten Halmahera Selatan
title_sort evaluasi jaringan tegangan menengah pasca bencana di kabupaten halmahera selatan
topic evaluasi jaringan distribusi 20 kv, rugi daya, jatuh tegangan,,etap 12.6.
url http://ejournal.patria-artha.ac.id/index.php/patj/article/view/355
work_keys_str_mv AT ramlyrasyid evaluasijaringanteganganmenengahpascabencanadikabupatenhalmaheraselatan