Evaluation of monoxide film-based dosimeters for surface dose detection in electron therapy.

Generally, electron therapy is applied to tumors on or close to the skin surface. However, this causes a variety of skin-related side effects. To alleviate the risk of these side effects, clinical treatment uses skin dosimeters to verify the therapeutic dose. However, dosimeters suffer from poor acc...

Full description

Bibliographic Details
Main Authors: Moo Jae Han, Seung Woo Yang, Sang Il Bae, Young Min Moon, Wan Jeon, Chul Won Choi, Sung Kwang Park, Jin Young Kim
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2021-01-01
Series:PLoS ONE
Online Access:https://doi.org/10.1371/journal.pone.0251441
_version_ 1818836422867550208
author Moo Jae Han
Seung Woo Yang
Sang Il Bae
Young Min Moon
Wan Jeon
Chul Won Choi
Sung Kwang Park
Jin Young Kim
author_facet Moo Jae Han
Seung Woo Yang
Sang Il Bae
Young Min Moon
Wan Jeon
Chul Won Choi
Sung Kwang Park
Jin Young Kim
author_sort Moo Jae Han
collection DOAJ
description Generally, electron therapy is applied to tumors on or close to the skin surface. However, this causes a variety of skin-related side effects. To alleviate the risk of these side effects, clinical treatment uses skin dosimeters to verify the therapeutic dose. However, dosimeters suffer from poor accuracy, because their attachment sites are approximated with the help of naked eyes. Therefore, a dosimeter based on a flexible material that can adjust to the contours of the human body is required. In this study, the reproducibility, linearity, dose-rate dependence, and percentage depth ionization (PDI) of PbO and HgO film-based dosimeters are evaluated to explore their potential as large-scale flexible dosimeters. The results demonstrate that both dosimeters deliver impressive reproducibility (within 1.5%) and linearity (≥ 0.9990). The relative standard deviations of the dose-rate dependence of the PbO and HgO dosimeters were 0.94% and 1.16% at 6 MeV, respectively, and 1.08% and 1.25% at 9 MeV, respectively, with the PbO dosimeter outperforming the 1.1% of existing diodes. The PDI analysis of the PbO and HgO dosimeters returned values of 0.014 cm (-0.074 cm) and 0.051 cm (-0.016 cm), respectively at 6 MeV (9 MeV) compared to the thimble chamber and R50. Therefore, the maximum error of each dosimeter is within the allowable range of 0.1 cm. In short, the analysis reveals that the PbO dosimeter delivers a superior performance relative to its HgO counterpart and has strong potential for use as a surface dosimeter. Thus, flexible monoxide materials have the necessary qualities to be used for dosimeters that meet the requisite quality assurance standards and can satisfy a variety of radiation-related applications as flexible functional materials.
first_indexed 2024-12-19T03:06:22Z
format Article
id doaj.art-95ecac52f7a44aba9c62bc9213e3bde6
institution Directory Open Access Journal
issn 1932-6203
language English
last_indexed 2024-12-19T03:06:22Z
publishDate 2021-01-01
publisher Public Library of Science (PLoS)
record_format Article
series PLoS ONE
spelling doaj.art-95ecac52f7a44aba9c62bc9213e3bde62022-12-21T20:38:06ZengPublic Library of Science (PLoS)PLoS ONE1932-62032021-01-01165e025144110.1371/journal.pone.0251441Evaluation of monoxide film-based dosimeters for surface dose detection in electron therapy.Moo Jae HanSeung Woo YangSang Il BaeYoung Min MoonWan JeonChul Won ChoiSung Kwang ParkJin Young KimGenerally, electron therapy is applied to tumors on or close to the skin surface. However, this causes a variety of skin-related side effects. To alleviate the risk of these side effects, clinical treatment uses skin dosimeters to verify the therapeutic dose. However, dosimeters suffer from poor accuracy, because their attachment sites are approximated with the help of naked eyes. Therefore, a dosimeter based on a flexible material that can adjust to the contours of the human body is required. In this study, the reproducibility, linearity, dose-rate dependence, and percentage depth ionization (PDI) of PbO and HgO film-based dosimeters are evaluated to explore their potential as large-scale flexible dosimeters. The results demonstrate that both dosimeters deliver impressive reproducibility (within 1.5%) and linearity (≥ 0.9990). The relative standard deviations of the dose-rate dependence of the PbO and HgO dosimeters were 0.94% and 1.16% at 6 MeV, respectively, and 1.08% and 1.25% at 9 MeV, respectively, with the PbO dosimeter outperforming the 1.1% of existing diodes. The PDI analysis of the PbO and HgO dosimeters returned values of 0.014 cm (-0.074 cm) and 0.051 cm (-0.016 cm), respectively at 6 MeV (9 MeV) compared to the thimble chamber and R50. Therefore, the maximum error of each dosimeter is within the allowable range of 0.1 cm. In short, the analysis reveals that the PbO dosimeter delivers a superior performance relative to its HgO counterpart and has strong potential for use as a surface dosimeter. Thus, flexible monoxide materials have the necessary qualities to be used for dosimeters that meet the requisite quality assurance standards and can satisfy a variety of radiation-related applications as flexible functional materials.https://doi.org/10.1371/journal.pone.0251441
spellingShingle Moo Jae Han
Seung Woo Yang
Sang Il Bae
Young Min Moon
Wan Jeon
Chul Won Choi
Sung Kwang Park
Jin Young Kim
Evaluation of monoxide film-based dosimeters for surface dose detection in electron therapy.
PLoS ONE
title Evaluation of monoxide film-based dosimeters for surface dose detection in electron therapy.
title_full Evaluation of monoxide film-based dosimeters for surface dose detection in electron therapy.
title_fullStr Evaluation of monoxide film-based dosimeters for surface dose detection in electron therapy.
title_full_unstemmed Evaluation of monoxide film-based dosimeters for surface dose detection in electron therapy.
title_short Evaluation of monoxide film-based dosimeters for surface dose detection in electron therapy.
title_sort evaluation of monoxide film based dosimeters for surface dose detection in electron therapy
url https://doi.org/10.1371/journal.pone.0251441
work_keys_str_mv AT moojaehan evaluationofmonoxidefilmbaseddosimetersforsurfacedosedetectioninelectrontherapy
AT seungwooyang evaluationofmonoxidefilmbaseddosimetersforsurfacedosedetectioninelectrontherapy
AT sangilbae evaluationofmonoxidefilmbaseddosimetersforsurfacedosedetectioninelectrontherapy
AT youngminmoon evaluationofmonoxidefilmbaseddosimetersforsurfacedosedetectioninelectrontherapy
AT wanjeon evaluationofmonoxidefilmbaseddosimetersforsurfacedosedetectioninelectrontherapy
AT chulwonchoi evaluationofmonoxidefilmbaseddosimetersforsurfacedosedetectioninelectrontherapy
AT sungkwangpark evaluationofmonoxidefilmbaseddosimetersforsurfacedosedetectioninelectrontherapy
AT jinyoungkim evaluationofmonoxidefilmbaseddosimetersforsurfacedosedetectioninelectrontherapy