Physical and technical aspects of quality assurance in mammography in the Republic of Srpska
Breast cancer is the most frequent malignant neoplasm affecting the female population. In order to reduce its morbidity and mortality rate, a mammography screening campaign has been established in both entities of Bosnia and Herzegovina. In this paper, a brief survey is given on the mammography...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
VINCA Institute of Nuclear Sciences
2011-01-01
|
Series: | Nuclear Technology and Radiation Protection |
Subjects: | |
Online Access: | http://www.doiserbia.nb.rs/img/doi/1451-3994/2011/1451-39941102171C.pdf |
_version_ | 1818252527960850432 |
---|---|
author | Ciraj-Bjelac Olivera F. Praskalo Jovica Ž. Davidović Jasna Đ. Živković Monika M. |
author_facet | Ciraj-Bjelac Olivera F. Praskalo Jovica Ž. Davidović Jasna Đ. Živković Monika M. |
author_sort | Ciraj-Bjelac Olivera F. |
collection | DOAJ |
description | Breast cancer is the most frequent malignant neoplasm affecting the female population. In order to reduce its morbidity and mortality rate, a mammography screening campaign has been established in both entities of Bosnia and Herzegovina. In this paper, a brief survey is given on the mammography screening practice in the Republic of Srpska. As an illustration, results of measurements of technical parameters, including mean glandular dose, for 31 mammography units are presented. Large fluctuations in dose among different measuring sites were found, unacceptable not only from the standpoint of mammography screening, but in clinical mammography as a whole. Subsequently, a series of quality control tests and corrective measures throughout the mammography imaging chain are proposed, in line with international guidelines and newly promulgated national legislation. Dose optimization and image quality improvement are the first and foremost goals to be achieved in order to setup a successful mammography screening program. |
first_indexed | 2024-12-12T16:25:36Z |
format | Article |
id | doaj.art-960044dc721247a6a0ec300975afa578 |
institution | Directory Open Access Journal |
issn | 1451-3994 |
language | English |
last_indexed | 2024-12-12T16:25:36Z |
publishDate | 2011-01-01 |
publisher | VINCA Institute of Nuclear Sciences |
record_format | Article |
series | Nuclear Technology and Radiation Protection |
spelling | doaj.art-960044dc721247a6a0ec300975afa5782022-12-22T00:18:53ZengVINCA Institute of Nuclear SciencesNuclear Technology and Radiation Protection1451-39942011-01-0126217117610.2298/NTRP1102171CPhysical and technical aspects of quality assurance in mammography in the Republic of SrpskaCiraj-Bjelac Olivera F.Praskalo Jovica Ž.Davidović Jasna Đ.Živković Monika M.Breast cancer is the most frequent malignant neoplasm affecting the female population. In order to reduce its morbidity and mortality rate, a mammography screening campaign has been established in both entities of Bosnia and Herzegovina. In this paper, a brief survey is given on the mammography screening practice in the Republic of Srpska. As an illustration, results of measurements of technical parameters, including mean glandular dose, for 31 mammography units are presented. Large fluctuations in dose among different measuring sites were found, unacceptable not only from the standpoint of mammography screening, but in clinical mammography as a whole. Subsequently, a series of quality control tests and corrective measures throughout the mammography imaging chain are proposed, in line with international guidelines and newly promulgated national legislation. Dose optimization and image quality improvement are the first and foremost goals to be achieved in order to setup a successful mammography screening program.http://www.doiserbia.nb.rs/img/doi/1451-3994/2011/1451-39941102171C.pdfmammography screeningquality controlmean glandular dose |
spellingShingle | Ciraj-Bjelac Olivera F. Praskalo Jovica Ž. Davidović Jasna Đ. Živković Monika M. Physical and technical aspects of quality assurance in mammography in the Republic of Srpska Nuclear Technology and Radiation Protection mammography screening quality control mean glandular dose |
title | Physical and technical aspects of quality assurance in mammography in the Republic of Srpska |
title_full | Physical and technical aspects of quality assurance in mammography in the Republic of Srpska |
title_fullStr | Physical and technical aspects of quality assurance in mammography in the Republic of Srpska |
title_full_unstemmed | Physical and technical aspects of quality assurance in mammography in the Republic of Srpska |
title_short | Physical and technical aspects of quality assurance in mammography in the Republic of Srpska |
title_sort | physical and technical aspects of quality assurance in mammography in the republic of srpska |
topic | mammography screening quality control mean glandular dose |
url | http://www.doiserbia.nb.rs/img/doi/1451-3994/2011/1451-39941102171C.pdf |
work_keys_str_mv | AT cirajbjelacoliveraf physicalandtechnicalaspectsofqualityassuranceinmammographyintherepublicofsrpska AT praskalojovicaz physicalandtechnicalaspectsofqualityassuranceinmammographyintherepublicofsrpska AT davidovicjasnađ physicalandtechnicalaspectsofqualityassuranceinmammographyintherepublicofsrpska AT zivkovicmonikam physicalandtechnicalaspectsofqualityassuranceinmammographyintherepublicofsrpska |