Physical and technical aspects of quality assurance in mammography in the Republic of Srpska

Breast cancer is the most frequent malignant neoplasm affecting the female population. In order to reduce its morbidity and mortality rate, a mammography screening campaign has been established in both entities of Bosnia and Herzegovina. In this paper, a brief survey is given on the mammography...

Full description

Bibliographic Details
Main Authors: Ciraj-Bjelac Olivera F., Praskalo Jovica Ž., Davidović Jasna Đ., Živković Monika M.
Format: Article
Language:English
Published: VINCA Institute of Nuclear Sciences 2011-01-01
Series:Nuclear Technology and Radiation Protection
Subjects:
Online Access:http://www.doiserbia.nb.rs/img/doi/1451-3994/2011/1451-39941102171C.pdf
_version_ 1818252527960850432
author Ciraj-Bjelac Olivera F.
Praskalo Jovica Ž.
Davidović Jasna Đ.
Živković Monika M.
author_facet Ciraj-Bjelac Olivera F.
Praskalo Jovica Ž.
Davidović Jasna Đ.
Živković Monika M.
author_sort Ciraj-Bjelac Olivera F.
collection DOAJ
description Breast cancer is the most frequent malignant neoplasm affecting the female population. In order to reduce its morbidity and mortality rate, a mammography screening campaign has been established in both entities of Bosnia and Herzegovina. In this paper, a brief survey is given on the mammography screening practice in the Republic of Srpska. As an illustration, results of measurements of technical parameters, including mean glandular dose, for 31 mammography units are presented. Large fluctuations in dose among different measuring sites were found, unacceptable not only from the standpoint of mammography screening, but in clinical mammography as a whole. Subsequently, a series of quality control tests and corrective measures throughout the mammography imaging chain are proposed, in line with international guidelines and newly promulgated national legislation. Dose optimization and image quality improvement are the first and foremost goals to be achieved in order to setup a successful mammography screening program.
first_indexed 2024-12-12T16:25:36Z
format Article
id doaj.art-960044dc721247a6a0ec300975afa578
institution Directory Open Access Journal
issn 1451-3994
language English
last_indexed 2024-12-12T16:25:36Z
publishDate 2011-01-01
publisher VINCA Institute of Nuclear Sciences
record_format Article
series Nuclear Technology and Radiation Protection
spelling doaj.art-960044dc721247a6a0ec300975afa5782022-12-22T00:18:53ZengVINCA Institute of Nuclear SciencesNuclear Technology and Radiation Protection1451-39942011-01-0126217117610.2298/NTRP1102171CPhysical and technical aspects of quality assurance in mammography in the Republic of SrpskaCiraj-Bjelac Olivera F.Praskalo Jovica Ž.Davidović Jasna Đ.Živković Monika M.Breast cancer is the most frequent malignant neoplasm affecting the female population. In order to reduce its morbidity and mortality rate, a mammography screening campaign has been established in both entities of Bosnia and Herzegovina. In this paper, a brief survey is given on the mammography screening practice in the Republic of Srpska. As an illustration, results of measurements of technical parameters, including mean glandular dose, for 31 mammography units are presented. Large fluctuations in dose among different measuring sites were found, unacceptable not only from the standpoint of mammography screening, but in clinical mammography as a whole. Subsequently, a series of quality control tests and corrective measures throughout the mammography imaging chain are proposed, in line with international guidelines and newly promulgated national legislation. Dose optimization and image quality improvement are the first and foremost goals to be achieved in order to setup a successful mammography screening program.http://www.doiserbia.nb.rs/img/doi/1451-3994/2011/1451-39941102171C.pdfmammography screeningquality controlmean glandular dose
spellingShingle Ciraj-Bjelac Olivera F.
Praskalo Jovica Ž.
Davidović Jasna Đ.
Živković Monika M.
Physical and technical aspects of quality assurance in mammography in the Republic of Srpska
Nuclear Technology and Radiation Protection
mammography screening
quality control
mean glandular dose
title Physical and technical aspects of quality assurance in mammography in the Republic of Srpska
title_full Physical and technical aspects of quality assurance in mammography in the Republic of Srpska
title_fullStr Physical and technical aspects of quality assurance in mammography in the Republic of Srpska
title_full_unstemmed Physical and technical aspects of quality assurance in mammography in the Republic of Srpska
title_short Physical and technical aspects of quality assurance in mammography in the Republic of Srpska
title_sort physical and technical aspects of quality assurance in mammography in the republic of srpska
topic mammography screening
quality control
mean glandular dose
url http://www.doiserbia.nb.rs/img/doi/1451-3994/2011/1451-39941102171C.pdf
work_keys_str_mv AT cirajbjelacoliveraf physicalandtechnicalaspectsofqualityassuranceinmammographyintherepublicofsrpska
AT praskalojovicaz physicalandtechnicalaspectsofqualityassuranceinmammographyintherepublicofsrpska
AT davidovicjasnađ physicalandtechnicalaspectsofqualityassuranceinmammographyintherepublicofsrpska
AT zivkovicmonikam physicalandtechnicalaspectsofqualityassuranceinmammographyintherepublicofsrpska